These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 10022788)

  • 41. Potentiodynamic polarization study of the corrosion behavior of palladium-silver dental alloys.
    Sun D; Brantley WA; Frankel GS; Heshmati RH; Johnston WM
    J Prosthet Dent; 2018 Apr; 119(4):650-656. PubMed ID: 28965676
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Corrosion resistance of NiTi in fluoride and acid environments.
    Benyahia H; Ebntouhami M; Forsal I; Zaoui F; Aalloula E
    Int Orthod; 2009 Dec; 7(4):322-34. PubMed ID: 20303919
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Characterization of hydroxyapatite containing a titania layer formed by anodization coupled with blasting.
    Kang MK; Moon SK; Kwon JS; Kim KM; Kim KN
    Acta Odontol Scand; 2014 Nov; 72(8):989-98. PubMed ID: 25005626
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
    Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
    Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Effect of casting technique on surface roughness and consequent mass loss after polishing of NiCr and CoCr base metal alloys: a comparative study with titanium.
    Bezzon OL; Pedrazzi H; Zaniquelli O; da Silva TB
    J Prosthet Dent; 2004 Sep; 92(3):274-7. PubMed ID: 15343163
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Characteristics of colored passive layers on zirconium: morphology, optical properties, and corrosion resistance.
    Holmberg RJ; Bolduc S; Beauchemin D; Jerkiewicz G; Schulz H; Kohlhaas U; Strzelecki H
    ACS Appl Mater Interfaces; 2012 Dec; 4(12):6487-98. PubMed ID: 23088502
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.
    Gil FJ; Canedo R; Padrós A; Bañeres MV; Arano JM
    Biomed Mater Eng; 2003; 13(1):27-34. PubMed ID: 12652020
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Corrosion behaviour of titanium in the presence of Streptococcus mutans.
    Souza JC; Ponthiaux P; Henriques M; Oliveira R; Teughels W; Celis JP; Rocha LA
    J Dent; 2013 Jun; 41(6):528-34. PubMed ID: 23578470
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Variation in corrosion resistance of nickel-titanium wires from different manufacturers.
    Huang HH
    Angle Orthod; 2005 Jul; 75(4):661-5. PubMed ID: 16097238
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Effect of surface treatments on adhesion of low-fusing porcelain to titanium as determined by strain energy release rate.
    Elsaka SE; Swain MV
    Dent Mater; 2011 Dec; 27(12):1213-20. PubMed ID: 21975306
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Evaluation of shear bond strength at the interface of two porcelains and pure titanium injected into the casting mold at three different temperatures.
    Bondioli IR; Bottino MA
    J Prosthet Dent; 2004 Jun; 91(6):541-7. PubMed ID: 15211296
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Effect of surface treatments on anodic oxide film growth and electrochemical properties of tantalum used for biomedical applications.
    Silva RA; Silva IP; Rondot B
    J Biomater Appl; 2006 Jul; 21(1):93-103. PubMed ID: 16443631
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Enhanced osteoblast proliferation and corrosion resistance of commercially pure titanium through surface nanostructuring by ultrasonic shot peening and stress relieving.
    Jindal S; Bansal R; Singh BP; Pandey R; Narayanan S; Wani MR; Singh V
    J Oral Implantol; 2014 Jul; 40 Spec No():347-55. PubMed ID: 25020216
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [Study of the correlation between Streptococcus mutans' adhesion and surface corrosion in casting titanium and Ti alloy].
    Shen XT; Liu L; Mo KN; Zhang YZ; Liang BG
    Shanghai Kou Qiang Yi Xue; 2008 Dec; 17(6):633-7. PubMed ID: 19148454
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The effect of simulated inflammatory conditions on the surface properties of titanium and stainless steel and their importance as biomaterials.
    Fonseca-García A; Pérez-Alvarez J; Barrera CC; Medina JC; Almaguer-Flores A; Sánchez RB; Rodil SE
    Mater Sci Eng C Mater Biol Appl; 2016 Sep; 66():119-129. PubMed ID: 27207045
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Influence of stress corrosion on the mechanical properties of laser-welded titanium.
    de Assis Ferreira N; Senna PM; do Lago DC; de Senna LF; Sampaio-Filho HR
    J Prosthet Dent; 2016 Mar; 115(3):356-62. PubMed ID: 26548870
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Attachment of Porphyromonas gingivalis to corroded commercially pure titanium and titanium-aluminum-vanadium alloy.
    Barão VA; Yoon CJ; Mathew MT; Yuan JC; Wu CD; Sukotjo C
    J Periodontol; 2014 Sep; 85(9):1275-82. PubMed ID: 24444400
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Surface analysis of machined versus sandblasted and acid-etched titanium implants.
    Orsini G; Assenza B; Scarano A; Piattelli M; Piattelli A
    Int J Oral Maxillofac Implants; 2000; 15(6):779-84. PubMed ID: 11151575
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.