These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 10025533)

  • 1. Differentiation between arterial and venous vessel occlusion by simultaneous measurement with laser Doppler flowmetry and photoplethysmography.
    Galla TJ; Hellekes D; Feller AM
    J Reconstr Microsurg; 1999 Jan; 15(1):67-72. PubMed ID: 10025533
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.
    Abay TY; Kyriacou PA
    Physiol Meas; 2016 Apr; 37(4):503-14. PubMed ID: 26963349
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monitoring of partial and full venous outflow obstruction in a porcine flap model using laser speckle contrast imaging.
    Zötterman J; Bergkvist M; Iredahl F; Tesselaar E; Farnebo S
    J Plast Reconstr Aesthet Surg; 2016 Jul; 69(7):936-43. PubMed ID: 27026039
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Inferior mesenteric venous sampling to detect colonic ischemia: a comparison with laser Doppler flowmetry and photoplethysmography.
    Avino AJ; Oldenburg WA; Gloviczki P; Miller VM; Burgart LJ; Atkinson EJ
    J Vasc Surg; 1995 Sep; 22(3):271-7; discussion 278-9. PubMed ID: 7674470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of microcirculation of the skin using Tissue Viability Imaging: A promising technique for detecting venous stasis in the skin.
    Bergkvist M; Henricson J; Iredahl F; Tesselaar E; Sjöberg F; Farnebo S
    Microvasc Res; 2015 Sep; 101():20-5. PubMed ID: 26092681
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurements of tissue blood flow by the hydrogen clearance technique (HCT): a comparative study including laser Doppler flowmetry (LDF) and the Erlangen micro-lightguide spectrophotometer (EMPHO).
    Machens HG; Pallua N; Mailaender P; Pasel J; Frank KH; Reimer R; Berger A
    Microsurgery; 1995; 16(12):808-17. PubMed ID: 8844663
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The optimal sequence of microvascular repair during prolonged clamping in free flap transfer.
    Braün SA; Mine R; Syed SA; Ta KT; Chao RP; Ciesielski TE; Perez-Morel A; Thomson JG
    Plast Reconstr Surg; 2003 Jan; 111(1):233-41. PubMed ID: 12496584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantifying the correlation between photoplethysmography and laser Doppler flowmetry microvascular low-frequency oscillations.
    Mizeva I; Di Maria C; Frick P; Podtaev S; Allen J
    J Biomed Opt; 2015 Mar; 20(3):037007. PubMed ID: 25764202
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Vascular Assessment in Patients With a Lower Limb Wound: A Correlational Study of Photoplethysmography and Laser Doppler Flowmetry Toe Pressure Techniques.
    Patry J; Laurencelle L; Bélisle J; Beaumier M
    J Diabetes Sci Technol; 2022 Mar; 16(2):470-477. PubMed ID: 33345614
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of vascular changes on the photoplethysmographic signal at different hand elevations.
    Hickey M; Phillips JP; Kyriacou PA
    Physiol Meas; 2015 Mar; 36(3):425-40. PubMed ID: 25652182
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Laser Doppler flowmetry predicts occlusion but not tPA-mediated reperfusion success after rat embolic stroke.
    Henninger N; Bouley J; Bråtane BT; Bastan B; Shea M; Fisher M
    Exp Neurol; 2009 Feb; 215(2):290-7. PubMed ID: 19038254
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.
    Phillips JP; Cibert-Goton V; Langford RM; Shortland PJ
    J Biomed Opt; 2013 Mar; 18(3):037005. PubMed ID: 23478810
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laser Doppler Flowmetry to Differentiate Arterial From Venous Occlusion in Free Tissue Transfer.
    Gazyakan E; Kao HK; Cheng MH; Engel H
    Plast Surg (Oakv); 2019 Nov; 27(4):297-304. PubMed ID: 31763329
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vascular changes associated with spinal root avulsion injury.
    Cibert-Goton V; Phillips JP; Shortland PJ
    Somatosens Mot Res; 2015; 32(3):158-62. PubMed ID: 25901469
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Examination of tissue oxygen saturation (StO2) changes associated with vascular pedicle occlusion in a rat Island flap model using near-Infrared spectroscopy.
    Kagaya Y; Ohura N; Kurita M; Takushima A; Harii K
    Microsurgery; 2015 Jul; 35(5):393-8. PubMed ID: 25639265
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laser Doppler flowmeter measurements of skin perfusion changes associated with arterial and venous compromise in the cutaneous island flap.
    Fischer JC; Parker PM; Shaw WW
    Microsurgery; 1985; 6(4):238-43. PubMed ID: 2935701
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Different lasers reveal different skin microcirculatory flowmotion - data from the wavelet transform analysis of human hindlimb perfusion.
    Rodrigues LM; Rocha C; Ferreira H; Silva H
    Sci Rep; 2019 Nov; 9(1):16951. PubMed ID: 31740748
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a non-invasive monitoring method for free flap breast reconstruction using laser doppler flowmetrie and tissue spectrophotometry.
    Rothenberger J; Amr A; Schaller HE; Rahmanian-Schwarz A
    Microsurgery; 2013 Jul; 33(5):350-7. PubMed ID: 23436443
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Distinguishing laser Doppler flowmetric responses between arterial and venous obstructions in flaps.
    Yuen JC; Feng Z
    J Reconstr Microsurg; 2000 Nov; 16(8):629-35. PubMed ID: 11127286
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of a modified oxygen microelectrode and laser-Doppler flowmetry to monitor changes in oxygen tension and microcirculation in a flap.
    Liss AG; Liss P
    Plast Reconstr Surg; 2000 May; 105(6):2072-8. PubMed ID: 10839404
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.