These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
138 related articles for article (PubMed ID: 10025615)
21. Doubling the resolution of echo-planar brain imaging by acquisition of two k-space lines per gradient reversal using TRAIL. Priest AN; De Vita E; Ordidge RJ NMR Biomed; 2008 Feb; 21(2):79-88. PubMed ID: 17506114 [TBL] [Abstract][Full Text] [Related]
22. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction. Zaitsev M; Hennig J; Speck O Magn Reson Med; 2004 Nov; 52(5):1156-66. PubMed ID: 15508146 [TBL] [Abstract][Full Text] [Related]
23. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging. Jezzard P; Barnett AS; Pierpaoli C Magn Reson Med; 1998 May; 39(5):801-12. PubMed ID: 9581612 [TBL] [Abstract][Full Text] [Related]
24. Optimization of diffusion-weighted single-refocused spin-echo EPI by reducing eddy-current artifacts and shortening the echo time. Shrestha M; Hok P; Nöth U; Lienerth B; Deichmann R MAGMA; 2018 Oct; 31(5):585-597. PubMed ID: 29603048 [TBL] [Abstract][Full Text] [Related]
25. Comparison of navigator echo and centroid corrections of image displacement induced by static magnetic field drift on echo planar functional MRI. Liu HL; Kochunov P; Lancaster JL; Fox PT; Gao JH J Magn Reson Imaging; 2001 Feb; 13(2):308-12. PubMed ID: 11169839 [TBL] [Abstract][Full Text] [Related]
26. Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors. Ianni JD; Welch EB; Grissom WA Magn Reson Med; 2018 Jun; 79(6):3114-3121. PubMed ID: 29034502 [TBL] [Abstract][Full Text] [Related]
28. Robust SENSE reconstruction of simultaneous multislice EPI with low-rank enhanced coil sensitivity calibration and slice-dependent 2D Nyquist ghost correction. Lyu M; Barth M; Xie VB; Liu Y; Ma X; Feng Y; Wu EX Magn Reson Med; 2018 Oct; 80(4):1376-1390. PubMed ID: 29427405 [TBL] [Abstract][Full Text] [Related]
29. Centric ordering is superior to gradient moment nulling for motion artifact reduction in EPI. Jaffer FA; Wen H; Jezzard P; Balaban RS; Wolff SD J Magn Reson Imaging; 1997; 7(6):1122-31. PubMed ID: 9400858 [TBL] [Abstract][Full Text] [Related]
30. Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data. Hoge WS; Polimeni JR Magn Reson Med; 2016 Jul; 76(1):32-44. PubMed ID: 26208304 [TBL] [Abstract][Full Text] [Related]
31. Artifacts caused by transcranial magnetic stimulation coils and EEG electrodes in T(2)*-weighted echo-planar imaging. Baudewig J; Paulus W; Frahm J Magn Reson Imaging; 2000 May; 18(4):479-84. PubMed ID: 10788726 [TBL] [Abstract][Full Text] [Related]
32. Diffusion-weighted multiple shot echo planar imaging of humans without navigation. Robson MD; Anderson AW; Gore JC Magn Reson Med; 1997 Jul; 38(1):82-8. PubMed ID: 9211383 [TBL] [Abstract][Full Text] [Related]
33. Robust EPI Nyquist ghost elimination via spatial and temporal encoding. Hoge WS; Tan H; Kraft RA Magn Reson Med; 2010 Dec; 64(6):1781-91. PubMed ID: 20665898 [TBL] [Abstract][Full Text] [Related]
34. EPI Nyquist ghost and geometric distortion correction by two-frame phase labeling. Xie VB; Lyu M; Wu EX Magn Reson Med; 2017 May; 77(5):1749-1761. PubMed ID: 27136196 [TBL] [Abstract][Full Text] [Related]
35. Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field. Yang QX; Wang J; Smith MB; Meadowcroft M; Sun X; Eslinger PJ; Golay X Magn Reson Med; 2004 Dec; 52(6):1418-23. PubMed ID: 15562468 [TBL] [Abstract][Full Text] [Related]