318 related articles for article (PubMed ID: 10037133)
1. Predictive value of past and current screening tests for syphilis in blood donors: changing from a rapid plasma reagin test to an automated specific treponemal test for screening.
Aberle-Grasse J; Orton SL; Notari E; Layug LP; Cable RG; Badon S; Popovsky MA; Grindon AJ; Lenes BA; Williams AE
Transfusion; 1999 Feb; 39(2):206-11. PubMed ID: 10037133
[TBL] [Abstract][Full Text] [Related]
2. Correlation of Treponemal Immunoassay Signal Strength Values with Reactivity of Confirmatory Treponemal Testing.
Fakile YF; Jost H; Hoover KW; Gustafson KJ; Novak-Weekley SM; Schapiro JM; Tran A; Chow JM; Park IU
J Clin Microbiol; 2018 Jan; 56(1):. PubMed ID: 29046410
[TBL] [Abstract][Full Text] [Related]
3. Confirmatory serological testing of blood donors positive on TPHA screening in Singapore.
Wong SS; Teo DL; Chan RK
Int J STD AIDS; 1997 Dec; 8(12):760-3. PubMed ID: 9433950
[TBL] [Abstract][Full Text] [Related]
4. Absence of risk factors for false-positive test results in blood donors with a reactive test result in an automated treponemal test (PK-TP) for syphilis.
Orton SL; Dodd RY; Williams AE;
Transfusion; 2001 Jun; 41(6):744-50. PubMed ID: 11399813
[TBL] [Abstract][Full Text] [Related]
5. Improving syphilis screening in deceased organ donors.
Theodoropoulos N; Jaramillo A; Penugonda S; Wasik C; Brooks K; Ladner DP; Jendrisak MD; Ison MG
Transplantation; 2015 Feb; 99(2):438-43. PubMed ID: 25073035
[TBL] [Abstract][Full Text] [Related]
6. The laboratory impact of changing syphilis screening from the rapid-plasma reagin to a treponemal enzyme immunoassay: a case-study from the Greater Toronto Area.
Mishra S; Boily MC; Ng V; Gold WL; Okura T; Shaw M; Mazzulli T; Fisman DN
Sex Transm Dis; 2011 Mar; 38(3):190-6. PubMed ID: 20706176
[TBL] [Abstract][Full Text] [Related]
7. Clinical Performance of the BioPlex 2200 Syphilis Total & RPR Assay at a Tertiary Medical Center with a High Rate of Syphilis.
Tesfazghi MT; Anderson NW; Gronowski AM; Yarbrough ML
J Clin Microbiol; 2019 Jan; 57(1):. PubMed ID: 30429251
[TBL] [Abstract][Full Text] [Related]
8. Discordant results from reverse sequence syphilis screening--five laboratories, United States, 2006-2010.
Centers for Disease Control and Prevention (CDC)
MMWR Morb Mortal Wkly Rep; 2011 Feb; 60(5):133-7. PubMed ID: 21307823
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of BioPlex 2200 Syphilis Total With Automated Rapid Plasma Reagin: Experience From a Tertiary Medical Center.
Tang EW; Paiva KJ; Pytel-Parenteau DL; Maynard MA; Chan PA; Lu S
Sex Transm Dis; 2020 May; 47(5):301-305. PubMed ID: 32073549
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.
Van Dyck E; Van de Velden L; Ndoye I; Piot P; Meheus A
Sex Transm Dis; 1993; 20(4):194-7. PubMed ID: 8211535
[TBL] [Abstract][Full Text] [Related]
11. Serologic response to treatment of infectious syphilis.
Romanowski B; Sutherland R; Fick GH; Mooney D; Love EJ
Ann Intern Med; 1991 Jun; 114(12):1005-9. PubMed ID: 2029095
[TBL] [Abstract][Full Text] [Related]
12. Characterization of sera with discordant results from reverse sequence screening for syphilis.
Lee K; Park H; Roh EY; Shin S; Park KU; Park MH; Song EY
Biomed Res Int; 2013; 2013():269347. PubMed ID: 23509699
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of a Rapid Syphilis Test in an Emergency Department Setting in Detroit, Michigan.
Fakile YF; Markowitz N; Zhu W; Mumby K; Dankerlui D; McCormick JK; Ham DC; Hopkins A; Manteuffel J; Sun Y; Huang YA; Peters PJ; Hoover KW
Sex Transm Dis; 2019 Jul; 46(7):429-433. PubMed ID: 30839394
[TBL] [Abstract][Full Text] [Related]
14. Comparison of an automated rapid plasma reagin (RPR) test with the conventional RPR card test in syphilis testing.
Lee JH; Lim CS; Lee MG; Kim HS
BMJ Open; 2014 Dec; 4(12):e005664. PubMed ID: 25552608
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the BioPlex 2200 syphilis total screen (IgG/IgM) with reflex to an automated rapid plasma reagin test.
Rourk AR; Litwin CM
J Clin Lab Anal; 2019 Jun; 33(5):e22878. PubMed ID: 30861169
[TBL] [Abstract][Full Text] [Related]
16. Current value of serologic test for syphilis as a surrogate marker for blood-borne viral infections among blood donors in the United States.
Zou S; Notari EP; Fang CT; Stramer SL; Dodd RY
Transfusion; 2009 Apr; 49(4):655-61. PubMed ID: 19170999
[TBL] [Abstract][Full Text] [Related]
17. The impact of combined antiretroviral therapy on biologic false-positive rapid plasma reagin serologies in a longitudinal cohort of HIV-infected persons.
Oboho IK; Gebo KA; Moore RD; Ghanem KG
Clin Infect Dis; 2013 Oct; 57(8):1197-202. PubMed ID: 23828913
[TBL] [Abstract][Full Text] [Related]
18. Challenges of Rapid Plasma Reagin Interpretation in Syphilis Screening in Uganda: Variability in Nontreponemal Results Between Different Laboratories.
Hamill MM; Mbazira KJ; Kiragga AN; Gaydos CA; Jett-Goheen M; Parkes-Ratanshi R; Manabe YC; Nakku-Joloba E; Rompalo A
Sex Transm Dis; 2018 Dec; 45(12):829-833. PubMed ID: 29944643
[TBL] [Abstract][Full Text] [Related]
19. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC).
Sarkodie F; Hassall O; Owusu-Dabo E; Owusu-Ofori S; Bates I; Bygbjerg IC; Owusu-Ofori A; Harritshøj LH; Ullum H
Transfus Med; 2017 Feb; 27(1):52-59. PubMed ID: 27723157
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of a colloidal gold immunochromatography assay in the detection of Treponema pallidum specific IgM antibody in syphilis serofast reaction patients: a serologic marker for the relapse and infection of syphilis.
Lin LR; Tong ML; Fu ZG; Dan B; Zheng WH; Zhang CG; Yang TC; Zhang ZY
Diagn Microbiol Infect Dis; 2011 May; 70(1):10-6. PubMed ID: 21388769
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]