197 related articles for article (PubMed ID: 10078235)
21. Evidence of bacterial biofilm in tubing from hydraulic pathway of hemodialysis system.
Man NK; Degremont A; Darbord JC; Collet M; Vaillant P
Artif Organs; 1998 Jul; 22(7):596-600. PubMed ID: 9684698
[TBL] [Abstract][Full Text] [Related]
22. Endotoxin-free dialysate improves response to erythropoietin in hemodialysis patients.
Matsuhashi N; Yoshioka T
Nephron; 2002; 92(3):601-4. PubMed ID: 12372943
[TBL] [Abstract][Full Text] [Related]
23. The effect of ultrafiltered dialysate on the cellular content of interleukin-1 receptor antagonist in patients on chronic hemodialysis.
Schindler R; Lonnemann G; Schäffer J; Shaldon S; Koch KM; Krautzig S
Nephron; 1994; 68(2):229-33. PubMed ID: 7830861
[TBL] [Abstract][Full Text] [Related]
24. Potential bacteriologic and endotoxin hazards associated with liquid bicarbonate concentrate.
Bland LA; Ridgeway MR; Aguero SM; Carson LA; Favero MS
ASAIO Trans; 1987; 33(3):542-5. PubMed ID: 3675985
[No Abstract] [Full Text] [Related]
25. Ultrapure dialysis water obtained with additional ultrafilter may reduce inflammation in patients on hemodialysis.
Di Iorio B; Di Micco L; Bruzzese D; Nardone L; Russo L; Formisano P; D'Esposito V; Russo D
J Nephrol; 2017 Dec; 30(6):795-801. PubMed ID: 28840494
[TBL] [Abstract][Full Text] [Related]
26. In search of sterile, endotoxin-free dialysate.
Gault MH; Duffett AL; Murphy JF; Purchase LH
ASAIO J; 1992; 38(3):M431-5. PubMed ID: 1457896
[TBL] [Abstract][Full Text] [Related]
27. Dialysate bath and QTc interval in patients on chronic maintenance hemodialysis: pilot study of single dialysis effects.
Di Iorio B; Torraca S; Piscopo C; Sirico ML; Di Micco L; Pota A; Tartaglia D; Berardino L; Morrone LF; Russo D
J Nephrol; 2012; 25(5):653-60. PubMed ID: 21983985
[TBL] [Abstract][Full Text] [Related]
28. Membranes for endotoxin removal from dialysate: considerations on feasibility of commercial ceramic membranes.
Bender H; Pfläzel A; Saunders N; Czermak P; Catapano G; Vienken J
Artif Organs; 2000 Oct; 24(10):826-9. PubMed ID: 11091173
[TBL] [Abstract][Full Text] [Related]
29. Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: a nationwide cohort study.
Hasegawa T; Nakai S; Masakane I; Watanabe Y; Iseki K; Tsubakihara Y; Akizawa T
Am J Kidney Dis; 2015 Jun; 65(6):899-904. PubMed ID: 25641063
[TBL] [Abstract][Full Text] [Related]
30. [A study on the endotoxin and bacterial contamination in reverse osmosis water and dialysis fluids].
Liu H; Li G; Zhang X; Duan X; Yao Y
Zhonghua Nei Ke Za Zhi; 1999 Dec; 38(12):806-9. PubMed ID: 11798721
[TBL] [Abstract][Full Text] [Related]
31. Effects of incubation time and temperature on microbiologic sampling procedures for hemodialysis fluids.
Arduino MJ; Bland LA; Aguero SM; Favero MS
J Clin Microbiol; 1991 Jul; 29(7):1462-5. PubMed ID: 1885742
[TBL] [Abstract][Full Text] [Related]
32. Detection of peptidoglycan and endotoxin in dialysate, using silkworm larvae plasma and limulus amebocyte lysate methods.
Tsuchida K; Takemoto Y; Yamagami S; Edney H; Niwa M; Tsuchiya M; Kishimoto T; Shaldon S
Nephron; 1997; 75(4):438-43. PubMed ID: 9127331
[TBL] [Abstract][Full Text] [Related]
33. Potency of endotoxin from bicarbonate dialysate compared with endotoxins from Escherichia coli and Shigella flexneri.
Bland LA; Oliver JC; Arduino MJ; Oettinger CW; McAllister SK; Favero MS
J Am Soc Nephrol; 1995 Feb; 5(8):1634-7. PubMed ID: 7756598
[TBL] [Abstract][Full Text] [Related]
34. Bacterial challenge of NISSHO ultrafilter ETF 609: results of in vitro testing.
Krautzig S; Lonnemann G; Shaldon S; Koch KM
Artif Organs; 1996 Jul; 20(7):798-800. PubMed ID: 8828771
[TBL] [Abstract][Full Text] [Related]
35. Calcium mass balances during standard bicarbonate hemodialysis and long-hour slow-flow bicarbonate hemodialysis.
Basile C; Libutti P; Di Turo AL; Tundo S; Maselli P; Casucci F; Losurdo N; Teutonico A; Vernaglione L; Lomonte C
J Nephrol; 2011; 24(6):742-8. PubMed ID: 21360470
[TBL] [Abstract][Full Text] [Related]
36. Microbial contamination of dialysate and its prevention in haemodialysis units.
Oie S; Kamiya A; Yoneda I; Uchiyama K; Tsuchida M; Takai K; Naito K
J Hosp Infect; 2003 Jun; 54(2):115-9. PubMed ID: 12818584
[TBL] [Abstract][Full Text] [Related]
37. Prescribing dialysate bicarbonate concentrations for hemodialysis patients.
Heineken FG; Brady-Smith M; Haynie J; Van Stone JC
Int J Artif Organs; 1988 Jan; 11(1):45-50. PubMed ID: 3360513
[TBL] [Abstract][Full Text] [Related]
38. [The level of endotoxins in hemodialysis water and dialysate].
Skarupskiene I; Bumblyte IA; Kuzminskis V
Medicina (Kaunas); 2007; 43 Suppl 1():81-4. PubMed ID: 17551282
[TBL] [Abstract][Full Text] [Related]
39. Ultrapure dialysate for home hemodialysis?
Ouseph R; Ward RA
Adv Chronic Kidney Dis; 2007 Jul; 14(3):256-62. PubMed ID: 17603979
[TBL] [Abstract][Full Text] [Related]
40. Ultrafiltration of dialysis fluid for hemodialysis.
Bambauer R; Jutzler GA; Schmidt R; Weber U; el-Saadi R; Oest A; Jung WK
ASAIO Trans; 1989; 35(3):516-9. PubMed ID: 2597522
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]