These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 10080631)

  • 21. Direct determination of benzamides in serum by column-switching high-performance liquid chromatography.
    Chiba R; Ogasawara A; Kubo T; Yamazaki H; Umino M; Ishizuka Y
    Anal Sci; 2003 May; 19(5):785-9. PubMed ID: 12769385
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Rapid measurement of estriol & estradiol by high performance liquid chromatography (HPLC)].
    Uchida N; Makino T; Kondo Z; Iizuka R
    Nihon Sanka Fujinka Gakkai Zasshi; 1984 Aug; 36(8):1249-53. PubMed ID: 6512340
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Simultaneous determination of codeine and its seven metabolites in plasma and urine by high-performance liquid chromatography with ultraviolet and electrochemical detection.
    He H; Shay SD; Caraco Y; Wood M; Wood AJ
    J Chromatogr B Biomed Sci Appl; 1998 Apr; 708(1-2):185-93. PubMed ID: 9653961
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection.
    del Rosario Brunetto M; Contreras Y; Clavijo S; Torres D; Delgado Y; Ovalles F; Ayala C; Gallignani M; Estela JM; Martin VC
    J Pharm Biomed Anal; 2009 Sep; 50(2):194-9. PubMed ID: 19446420
    [TBL] [Abstract][Full Text] [Related]  

  • 25. New sensitive assay of vancomycin in human plasma using high-performance liquid chromatography and electrochemical detection.
    Favetta P; Guitto J; Bleyzac N; Dufresne C; Bureau J
    J Chromatogr B Biomed Sci Appl; 2001 Feb; 751(2):377-82. PubMed ID: 11236095
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection.
    Inoue K; Kato K; Yoshimura Y; Makino T; Nakazawa H
    J Chromatogr B Biomed Sci Appl; 2000 Nov; 749(1):17-23. PubMed ID: 11129074
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Automated direct high-performance liquid chromatographic assay for estetrol, estriol, cortisone and cortisol in serum and amniotic fluid.
    Noma J; Hayashi N; Sekiba K
    J Chromatogr; 1991 Jul; 568(1):35-44. PubMed ID: 1770108
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High-performance liquid chromatography method for the simultaneous determination of thiamine hydrochloride, pyridoxine hydrochloride and cyanocobalamin in pharmaceutical formulations using coulometric electrochemical and ultraviolet detection.
    Marszałł ML; Lebiedzińska A; Czarnowski W; Szefer P
    J Chromatogr A; 2005 Nov; 1094(1-2):91-8. PubMed ID: 16257294
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method.
    Kumihashi M; Ameno K; Shibayama T; Suga K; Miyauchi H; Jamal M; Wang W; Uekita I; Ijiri I
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jan; 845(1):180-3. PubMed ID: 16916628
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Determination of atorvastatin in human serum by reversed-phase high-performance liquid chromatography with UV detection.
    Bahrami G; Mohammadi B; Mirzaeei S; Kiani A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Nov; 826(1-2):41-5. PubMed ID: 16150657
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Determination of clozapine, desmethylclozapine and clozapine N-oxide in human plasma by reversed-phase high-performance liquid chromatography with ultraviolet detection.
    Avenoso A; Facciolà G; Campo GM; Fazio A; Spina E
    J Chromatogr B Biomed Sci Appl; 1998 Sep; 714(2):299-308. PubMed ID: 9766870
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Analysis of coenzyme Q(10) in human plasma by column-switching liquid chromatography.
    Jiang P; Wu M; Zheng Y; Wang C; Li Y; Xin J; Xu G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jun; 805(2):297-301. PubMed ID: 15135104
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Simultaneous determination of NK-104 and its lactone in biological samples by column-switching high-performance liquid chromatography with ultraviolet detection.
    Kojima J; Fujino H; Yosimura M; Morikawa H; Kimata H
    J Chromatogr B Biomed Sci Appl; 1999 Mar; 724(1):173-80. PubMed ID: 10202970
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Selective and sensitive assay for the determination of benzodiazepines by high-performance liquid chromatography with simultaneous ultraviolet and reductive electrochemical detection at the hanging mercury drop electrode.
    Wilhelm M; Battista HJ; Obendorf D
    J Chromatogr A; 2000 Nov; 897(1-2):215-25. PubMed ID: 11128205
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High-performance liquid chromatographic methods for the determination of a new carbapenem antibiotic, L-749,345, in human plasma and urine.
    Musson DG; Birk KL; Cairns AM; Majumdar AK; Rogers JD
    J Chromatogr B Biomed Sci Appl; 1998 Dec; 720(1-2):99-106. PubMed ID: 9892072
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determination of isoflavones in soybean food and human urine using liquid chromatography with electrochemical detection.
    Klejdus B; Vacek J; Adam V; Zehnálek J; Kizek R; Trnková L; Kubán V
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jul; 806(2):101-11. PubMed ID: 15171918
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Automated and sensitive method for the determination of formoterol in human plasma by high-performance liquid chromatography and electrochemical detection.
    Campestrini J; Lecaillon JB; Godbillon J
    J Chromatogr B Biomed Sci Appl; 1997 Dec; 704(1-2):221-9. PubMed ID: 9518154
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Simultaneous determination of palladium, platinum and rhodium by on-line column enrichment and HPLC with 5-(2,4-dihydroxyphenylazo)-rhodanine as pre-column derivatization reagent.
    Li Z; Li X; Hu Q; Yin J; Chzn J; Yang G
    Ann Chim; 2006; 96(5-6):355-63. PubMed ID: 16856765
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Determination of manidipine and its pyridine metabolite in human serum by high-performance liquid chromatography with ultraviolet detection and column switching.
    Miyabayashi T; Yamashita K; Aoki I; Motohashi M; Yashiki T; Yatani K
    J Chromatogr; 1989 Sep; 494():209-17. PubMed ID: 2584318
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Simultaneous determination of four heavy metal ions in tobacco and tobacco additive by online enrichment followed by RP-HPLC and microwave digestion.
    Yang G; Zhang C; Wang Q; Yin J
    J Chromatogr Sci; 2003 Apr; 41(4):195-9. PubMed ID: 12803807
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.