122 related articles for article (PubMed ID: 10084102)
1. Calculated and measured oxygen consumption in mechanically ventilated surgical patients in the early post-operative period.
Brandi LS; Bertolini R; Santini L
Eur J Anaesthesiol; 1999 Jan; 16(1):53-61. PubMed ID: 10084102
[TBL] [Abstract][Full Text] [Related]
2. Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor.
Brandi LS; Bertolini R; Pieri M; Giunta F; CalafĂ M
Intensive Care Med; 1997 Aug; 23(8):908-15. PubMed ID: 9310812
[TBL] [Abstract][Full Text] [Related]
3. Comparison of oxygen consumption calculated by Fick's principle (using a central venous catheter) and measured by indirect calorimetry.
Inadomi C; Terao Y; Yamashita K; Fukusaki M; Takada M; Sumikawa K
J Anesth; 2008; 22(2):163-6. PubMed ID: 18500614
[TBL] [Abstract][Full Text] [Related]
4. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
Chang AC; Kulik TJ; Hickey PR; Wessel DL
Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
[TBL] [Abstract][Full Text] [Related]
5. Comparison of methods of measurements of oxygen consumption in mechanically ventilated patients with multiple trauma: the Fick method versus indirect calorimetry.
Epstein CD; Peerless JR; Martin JE; Malangoni MA
Crit Care Med; 2000 May; 28(5):1363-9. PubMed ID: 10834679
[TBL] [Abstract][Full Text] [Related]
6. Oxygen consumption after cardiopulmonary bypass--implications of different measuring methods.
Oudemans-van Straaten HM; Scheffer GJ; Eysman L; Wildevuur CR
Intensive Care Med; 1993; 19(2):105-10. PubMed ID: 8486864
[TBL] [Abstract][Full Text] [Related]
7. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient.
Brandi LS; Bertolini R; Santini L; Cavani S
Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532
[TBL] [Abstract][Full Text] [Related]
8. Calculated versus measured oxygen consumption during and after cardiac surgery. Is it possible to estimate lung oxygen consumption?
Keinänen O; Takala J
Acta Anaesthesiol Scand; 1997 Aug; 41(7):803-9. PubMed ID: 9265920
[TBL] [Abstract][Full Text] [Related]
9. Oxygen Fick and modified carbon dioxide Fick cardiac outputs.
Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS
Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981
[TBL] [Abstract][Full Text] [Related]
10. A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure.
Walsh TS; Hopton P; Lee A
Crit Care Med; 1998 Jul; 26(7):1200-7. PubMed ID: 9671369
[TBL] [Abstract][Full Text] [Related]
11. Direct calorimetry using Swan-Ganz catheter for evaluation of general metabolic expenditure in acute cerebrovascular disease--comparison between direct Fick method and indirect calorimetry technique.
Touho H; Karasawa J; Shishido H; Yamada K; Shibamoto K
Neurol Med Chir (Tokyo); 1991 Nov; 31(11):691-4. PubMed ID: 1723155
[TBL] [Abstract][Full Text] [Related]
12. Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method.
Smithies MN; Royston B; Makita K; Konieczko K; Nunn JF
Crit Care Med; 1991 Nov; 19(11):1401-6. PubMed ID: 1935161
[TBL] [Abstract][Full Text] [Related]
13. Indirect Calorimetry Overestimates Oxygen Consumption in Young Children: Caution is Advised Using Direct Fick Method as a Reference Method in Cardiac Output Comparison Studies.
Sigurdsson TS; Lindberg L
Pediatr Cardiol; 2020 Jan; 41(1):149-154. PubMed ID: 31741015
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of oxygen uptake and delivery in critically ill patients: a statistical reappraisal.
Hanique G; Dugernier T; Laterre PF; Roeseler J; Dougnac A; Reynaert MS
Intensive Care Med; 1994; 20(1):19-26. PubMed ID: 8163753
[TBL] [Abstract][Full Text] [Related]
15. Oxygen consumption calculated from the Fick equation has limited utility.
Stock MC; Ryan ME
Crit Care Med; 1996 Jan; 24(1):86-90. PubMed ID: 8565544
[TBL] [Abstract][Full Text] [Related]
16. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry.
Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E
Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442
[TBL] [Abstract][Full Text] [Related]
17. Spirometric versus Fick-derived oxygen consumption: which method is better?
Thrush DN
Crit Care Med; 1996 Jan; 24(1):91-5. PubMed ID: 8565545
[TBL] [Abstract][Full Text] [Related]
18. Noninvasive Cardiac Output Estimation by Inert Gas Rebreathing in Mechanically Ventilated Pediatric Patients.
Perak AM; Opotowsky AR; Walsh BK; Esch JJ; DiNardo JA; Kussman BD; Porras D; Rhodes J
J Pediatr; 2016 Oct; 177():184-190.e3. PubMed ID: 27499214
[TBL] [Abstract][Full Text] [Related]
19. Different dosages of dobutamine in septic shock patients: determining oxygen consumption with a metabolic monitor integrated in a ventilator.
Schaffartzik W; Sanft C; Schaefer JH; Spies C
Intensive Care Med; 2000 Dec; 26(12):1740-6. PubMed ID: 11271080
[TBL] [Abstract][Full Text] [Related]
20. Correlation between oxygen consumption calculated using Fick's method and measured with indirect calorimetry in critically ill patients.
Marson F; Auxiliadora Martins M; Coletto FA; Campos AD; Basile-Filho A
Arq Bras Cardiol; 2004 Jan; 82(1):77-81, 72-6. PubMed ID: 14978596
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]