These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 10090585)

  • 1. Falsely elevated intraocular pressure due to increased central corneal thickness.
    Bron AM; Creuzot-Garcher C; Goudeau-Boutillon S; d'Athis P
    Graefes Arch Clin Exp Ophthalmol; 1999 Mar; 237(3):220-4. PubMed ID: 10090585
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data: prospective analysis of biophysical parameters in tertiary glaucoma practice populations.
    Kniestedt C; Lin S; Choe J; Nee M; Bostrom A; Stürmer J; Stamper RL
    J Glaucoma; 2006 Apr; 15(2):91-7. PubMed ID: 16633220
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study.
    Wolfs RC; Klaver CC; Vingerling JR; Grobbee DE; Hofman A; de Jong PT
    Am J Ophthalmol; 1997 Jun; 123(6):767-72. PubMed ID: 9535620
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension.
    Singh RP; Goldberg I; Graham SL; Sharma A; Mohsin M
    J Glaucoma; 2001 Jun; 10(3):206-10. PubMed ID: 11442184
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.
    Ventura AC; Böhnke M; Mojon DS
    Br J Ophthalmol; 2001 Jul; 85(7):792-5. PubMed ID: 11423450
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Central corneal thickness in low-tension glaucoma.
    Emara BY; Tingey DP; Probst LE; Motolko MA
    Can J Ophthalmol; 1999 Oct; 34(6):319-24. PubMed ID: 10604052
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Falsely elevated intraocular pressure due to an abnormally thick cornea in a patient with nevus of Ota.
    Kitagawa K; Hayasaka S; Nagaki Y
    Jpn J Ophthalmol; 2003; 47(2):142-4. PubMed ID: 12738546
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer.
    Saleh TA; Adams M; McDermott B; Claridge KG; Ewings P
    Clin Exp Ophthalmol; 2006 Aug; 34(6):516-20. PubMed ID: 16925697
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.
    Gunvant P; Baskaran M; Vijaya L; Joseph IS; Watkins RJ; Nallapothula M; Broadway DC; O'Leary DJ
    Br J Ophthalmol; 2004 Apr; 88(4):518-22. PubMed ID: 15031169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correlation between Central Corneal Thickness and Intraocular Pressure Measured by Goldmann Applanation Tonometry or Pascal Dynamic Contour Tonometry.
    Katsimpris JM; Theoulakis PE; Vasilopoulos K; Skourtis G; Papadopoulos GE; Petropoulos IK
    Klin Monbl Augenheilkd; 2015 Apr; 232(4):414-8. PubMed ID: 25902089
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Central corneal thickness and its association with ocular and general parameters in Indians: the Central India Eye and Medical Study.
    Nangia V; Jonas JB; Sinha A; Matin A; Kulkarni M
    Ophthalmology; 2010 Apr; 117(4):705-10. PubMed ID: 20045561
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry.
    Martinez-de-la-Casa JM; Garcia-Feijoo J; Vico E; Fernandez-Vidal A; Benitez del Castillo JM; Wasfi M; Garcia-Sanchez J
    Ophthalmology; 2006 Dec; 113(12):2156-62. PubMed ID: 16996599
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Applanation tonometry and correction according to corneal thickness.
    Stodtmeister R
    Acta Ophthalmol Scand; 1998 Jun; 76(3):319-24. PubMed ID: 9686845
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationship between central corneal thickness and changes of optic nerve head topography and blood flow after intraocular pressure reduction in open-angle glaucoma and ocular hypertension.
    Lesk MR; Hafez AS; Descovich D
    Arch Ophthalmol; 2006 Nov; 124(11):1568-72. PubMed ID: 17102003
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Central and paracentral corneal pachymetry in patients with normal tension glaucoma and ocular hypertension.
    Jordan JF; Joergens S; Dinslage S; Dietlein TS; Krieglstein GK
    Graefes Arch Clin Exp Ophthalmol; 2006 Feb; 244(2):177-82. PubMed ID: 16075223
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes.
    Herndon LW; Choudhri SA; Cox T; Damji KF; Shields MB; Allingham RR
    Arch Ophthalmol; 1997 Sep; 115(9):1137-41. PubMed ID: 9298054
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ocular hypertension and central corneal thickness.
    Argus WA
    Ophthalmology; 1995 Dec; 102(12):1810-2. PubMed ID: 9098281
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corneal thickness measurements and visual function abnormalities in ocular hypertensive patients.
    Medeiros FA; Sample PA; Weinreb RN
    Am J Ophthalmol; 2003 Feb; 135(2):131-7. PubMed ID: 12566014
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma.
    Copt RP; Thomas R; Mermoud A
    Arch Ophthalmol; 1999 Jan; 117(1):14-6. PubMed ID: 9930155
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry.
    Kniestedt C; Lin S; Choe J; Bostrom A; Nee M; Stamper RL
    Arch Ophthalmol; 2005 Nov; 123(11):1532-7. PubMed ID: 16286615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.