These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 10146440)

  • 1. Evaluation of wear in an all-polymer total knee replacement. Part 1: laboratory testing of polyethylene on polyacetal bearing surfaces.
    McKellop HA; Röstlund T; Bradley G
    Clin Mater; 1993; 14(2):117-26. PubMed ID: 10146440
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of wear in an all-polymer total knee replacement. Part 2: clinical evaluation of wear in a polyethylene on polyacetal total knee.
    Bradley GW; Freeman MA; Tuke MA; McKellop HA
    Clin Mater; 1993; 14(2):127-32. PubMed ID: 10146441
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls.
    Liao YS; McKellop H; Lu Z; Campbell P; Benya P
    Biomaterials; 2003 Aug; 24(18):3047-59. PubMed ID: 12895577
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biological impact of polyacetal particles on loosening of isoelastic stems.
    Strazar K; Cör A; Antolic V
    Biomacromolecules; 2006 Sep; 7(9):2507-11. PubMed ID: 16961311
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model.
    Sorimachi T; Clarke IC; Williams PA; Gustafson A; Yamamoto K
    Proc Inst Mech Eng H; 2009 Jul; 223(5):607-23. PubMed ID: 19623913
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Experimental studies on polyacetal composites for joint prosthesis].
    Maeda M
    Nihon Seikeigeka Gakkai Zasshi; 1984 Sep; 58(9):919-36. PubMed ID: 6520501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device.
    McKellop H; Clarke I; Markolf K; Amstutz H
    J Biomed Mater Res; 1981 Sep; 15(5):619-53. PubMed ID: 12659132
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frictional heating of bearing materials tested in a hip joint wear simulator.
    Lu Z; McKellop H
    Proc Inst Mech Eng H; 1997; 211(1):101-8. PubMed ID: 9141895
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wear evaluation of cobalt-chromium alloy for use in a metal-on-metal hip prosthesis.
    St John KR; Zardiackas LD; Poggie RA
    J Biomed Mater Res B Appl Biomater; 2004 Jan; 68(1):1-14. PubMed ID: 14689490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wear of the acetabular socket. Comparison of polyacetal and polyethylene.
    Mathiesen EB; Lindgren U; Reinholt FP; Sudmann E
    Acta Orthop Scand; 1986 Jun; 57(3):193-6. PubMed ID: 3739654
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can a total knee replacement prosthesis be made entirely of polymers?
    Moore DJ; Freeman MA; Revell PA; Bradley GW; Tuke M
    J Arthroplasty; 1998 Jun; 13(4):388-95. PubMed ID: 9645518
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.
    McKellop H; Shen FW; DiMaio W; Lancaster JG
    Clin Orthop Relat Res; 1999 Dec; (369):73-82. PubMed ID: 10611862
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Potential thermal artifacts in hip joint wear simulators.
    Lu Z; McKellop H; Liao P; Benya P
    J Biomed Mater Res; 1999; 48(4):458-64. PubMed ID: 10421687
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls.
    Shen FW; McKellop H
    Clin Orthop Relat Res; 2005 Jan; (430):80-8. PubMed ID: 15662307
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.
    Saikko V; Ahlroos T; Calonius O; Keränen J
    Biomaterials; 2001 Jun; 22(12):1507-14. PubMed ID: 11374449
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tissue reactions to wear products from polyacetal (Delrin) and UHMW polyethylene in total hip replacement.
    Mathiesen EB; Lindgren JU; Reinholt FP; Sudmann E
    J Biomed Mater Res; 1987 Apr; 21(4):459-66. PubMed ID: 3294838
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies.
    Affatato S; Traina F; Ruggeri O; Toni A
    Int J Artif Organs; 2011 Dec; 34(12):1155-64. PubMed ID: 22198601
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Alternative bearing surfaces for total joint arthroplasty.
    Jazrawi LM; Kummer FJ; DiCesare PE
    J Am Acad Orthop Surg; 1998; 6(4):198-203. PubMed ID: 9682082
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.