These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 10171538)

  • 21. Corrosion behaviour of dental metals and alloys in different media.
    Kedici SP; Aksüt AA; Kílíçarslan MA; Bayramoğlu G; Gökdemir K
    J Oral Rehabil; 1998 Oct; 25(10):800-8. PubMed ID: 9802590
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Corrosion potential in artificial saliva and possible genotoxic and cytotoxic damage in buccal epithelial cells of patients who underwent Ni-Cr based porcelain-fused-to-metal fixed dental prostheses.
    Alp G; Çakmak G; Sert M; Burgaz Y
    Mutat Res Genet Toxicol Environ Mutagen; 2018 Mar; 827():19-26. PubMed ID: 29502734
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of nickel addition on microstructure and properties of Ti-Co-Ni alloys.
    Chern Lin JH; Chen YF; Ju CP
    Biomaterials; 1995 Dec; 16(18):1401-7. PubMed ID: 8590767
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cobalt-base alloys used in bone surgery.
    Marti A
    Injury; 2000 Dec; 31 Suppl 4():18-21. PubMed ID: 11270075
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Study on high temperature oxidation of Ni-Cr ceramic alloys. Effects of Cr and Mo].
    Mizutani M
    Aichi Gakuin Daigaku Shigakkai Shi; 1990 Mar; 28(1 Pt 1):59-78. PubMed ID: 2135111
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effects of recasting on the amount of corrosion products released from two Ni-Cr base metal alloys.
    Ozdemir S; Arikan A
    Eur J Prosthodont Restor Dent; 1998 Dec; 6(4):149-53. PubMed ID: 10596615
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The electrochemical behaviour of various non-precious Ni and Co based alloys in artificial saliva.
    Mareci D; Nemtoi G; Aelenei N; Bocanu C
    Eur Cell Mater; 2005 Jul; 10():1-7; discussion 1-7. PubMed ID: 16003609
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Corrosion behaviour, metal release and biocompatibility of implant materials coated by TiO2-sol gel chemistry].
    Hoffmann B; Kokott A; Shafranska O; Detsch R; Winter S; Eisenbarth E; Peters K; Breme J; Kirkpatrick CJ; Ziegler G
    Biomed Tech (Berl); 2005 Oct; 50(10):320-9. PubMed ID: 16300047
    [TBL] [Abstract][Full Text] [Related]  

  • 29. In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants.
    Fathi MH; Salehi M; Saatchi A; Mortazavi V; Moosavi SB
    Dent Mater; 2003 May; 19(3):188-98. PubMed ID: 12628430
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations.
    Viennot S; Dalard F; Lissac M; Grosgogeat B
    Eur J Oral Sci; 2005 Feb; 113(1):90-5. PubMed ID: 15693835
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Corrosion behaviour of cobalt-chromium dental alloys doped with precious metals.
    Reclaru L; Lüthy H; Eschler PY; Blatter A; Susz C
    Biomaterials; 2005 Jul; 26(21):4358-65. PubMed ID: 15701364
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrochemical corrosion of metallic biomaterials.
    Pourbaix M
    Biomaterials; 1984 May; 5(3):122-34. PubMed ID: 6375748
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.
    Iijima M; Endo K; Ohno H; Mizoguchi I
    Dent Mater J; 1998 Mar; 17(1):31-40. PubMed ID: 9663060
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Diamondlike carbon coating as a galvanic corrosion barrier between dental implant abutments and nickel-chromium superstructures.
    Ozkomur A; Erbil M; Akova T
    Int J Oral Maxillofac Implants; 2013; 28(4):1037-47. PubMed ID: 23869362
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Discrepancies in marginal and internal fits for different metal and alumina infrastructures cemented on implant abutments.
    Faot F; Suzuki D; Senna PM; da Silva WJ; de Mattias Sartori IA
    Eur J Oral Sci; 2015 Jun; 123(3):215-9. PubMed ID: 25809785
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.
    Williams S; Tipper JL; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2003; 217(3):155-63. PubMed ID: 12807156
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Properties of test metal ceramic titanium alloys.
    Akagi K; Okamoto Y; Matsuura T; Horibe T
    J Prosthet Dent; 1992 Sep; 68(3):462-7. PubMed ID: 1432762
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surface characteristics and corrosion properties of selective laser melted Co-Cr dental alloy after porcelain firing.
    Xin XZ; Chen J; Xiang N; Gong Y; Wei B
    Dent Mater; 2014 Mar; 30(3):263-70. PubMed ID: 24388219
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Corrosion evaluation of recasting non-precious dental alloys.
    Khamis E; Seddik M
    Int Dent J; 1995 Jun; 45(3):209-17. PubMed ID: 7558360
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The in vitro toxicity of cobalt-chrome-molybdenum alloy and its constituent metals.
    Evans EJ; Thomas IT
    Biomaterials; 1986 Jan; 7(1):25-9. PubMed ID: 3955154
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.