These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 10191777)

  • 1. Technical evaluation of five glucose meters with data management capabilities.
    Chance JJ; Li DJ; Jones KA; Dyer KL; Nichols JH
    Am J Clin Pathol; 1999 Apr; 111(4):547-56. PubMed ID: 10191777
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laboratory and bedside evaluation of portable glucose meters.
    Nichols JH; Howard C; Loman K; Miller C; Nyberg D; Chan DW
    Am J Clin Pathol; 1995 Feb; 103(2):244-51. PubMed ID: 7856571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An evaluation of three glucose meter systems and their performance in relation to criteria of acceptability for neonatal specimens.
    St-Louis P; Ethier J
    Clin Chim Acta; 2002 Aug; 322(1-2):139-48. PubMed ID: 12104093
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interference studies with two hospital-grade and two home-grade glucose meters.
    Lyon ME; Baskin LB; Braakman S; Presti S; Dubois J; Shirey T
    Diabetes Technol Ther; 2009 Oct; 11(10):641-7. PubMed ID: 19821756
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of blood glucose monitoring devices.
    Chen ET; Nichols JH; Duh SH; Hortin G
    Diabetes Technol Ther; 2003; 5(5):749-68. PubMed ID: 14633341
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A mathematical model to assess the influence of hematocrit on point of care glucose meter performance.
    Lyon ME; Gray D; Baskin LB; Dubois JA; Lyon AW
    Clin Biochem; 2010 Jul; 43(10-11):905-9. PubMed ID: 20346933
    [TBL] [Abstract][Full Text] [Related]  

  • 7. SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use.
    Jansen RT; Slingerland RJ
    Clin Chem Lab Med; 2010 Jul; 48(7):1021-7. PubMed ID: 20459353
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters.
    Karon BS; Griesmann L; Scott R; Bryant SC; Dubois JA; Shirey TL; Presti S; Santrach PJ
    Diabetes Technol Ther; 2008 Apr; 10(2):111-20. PubMed ID: 18260774
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The variability of results between point-of-care testing glucose meters and the central laboratory analyzer.
    Khan AI; Vasquez Y; Gray J; Wians FH; Kroll MH
    Arch Pathol Lab Med; 2006 Oct; 130(10):1527-32. PubMed ID: 17090196
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plasma-equivalent glucose at the point-of-care: evaluation of Roche Accu-Chek Inform and Abbott Precision PCx glucose meters.
    Ghys T; Goedhuys W; Spincemaille K; Gorus F; Gerlo E
    Clin Chim Acta; 2007; 386(1-2):63-8. PubMed ID: 17727831
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction.
    Rao LV; Jakubiak F; Sidwell JS; Winkelman JW; Snyder ML
    Clin Chim Acta; 2005 Jun; 356(1-2):178-83. PubMed ID: 15936315
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of GLUCOCARD X-METER glucose monitoring system].
    Kwon MJ; Lee SY
    Korean J Lab Med; 2008 Feb; 28(1):8-15. PubMed ID: 18309250
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ambulatory patients in the United States and Canada.
    Kost GJ; Vu HT; Lee JH; Bourgeois P; Kiechle FL; Martin C; Miller SS; Okorodudu AO; Podczasy JJ; Webster R; Whitlow KJ
    Crit Care Med; 1998 Mar; 26(3):581-90. PubMed ID: 9504590
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative Accuracy Evaluation of a Blood Glucose Meter With Novel Hematocrit Correction Technology, With Three Currently Used Commercially Available Blood Glucose Monitoring Systems.
    Dunseath GJ; Bright D; Luzio SD
    J Diabetes Sci Technol; 2019 May; 13(3):568-574. PubMed ID: 30623673
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Maltose interference-free test strips for blood glucose testing at point-of-care: a laboratory performance evaluation.
    Ng WY; Tiong CC; Jacob E
    Diabetes Technol Ther; 2010 Nov; 12(11):889-93. PubMed ID: 20879959
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of a new interference-resistant glucose meter.
    Vanavanan S; Santanirand P; Chaichanajarernkul U; Chittamma A; Dubois JA; Shirey T; Heinz M
    Clin Biochem; 2010 Jan; 43(1-2):186-92. PubMed ID: 19769953
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Can one point-of-care glucose meter be used for all pediatric and adult hospital patients? Evaluation of three meters, including recently modified test strips.
    Warner JV; Wu JY; Buckingham N; McLeod DS; Mottram B; Carter AC
    Diabetes Technol Ther; 2011 Jan; 13(1):55-62. PubMed ID: 21175272
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Estimates of total analytical error in consumer and hospital glucose meters contributed by hematocrit, maltose, and ascorbate.
    Lyon ME; DuBois JA; Fick GH; Lyon AW
    J Diabetes Sci Technol; 2010 Nov; 4(6):1479-94. PubMed ID: 21129345
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing.
    Tang Z; Lee JH; Louie RF; Kost GJ
    Arch Pathol Lab Med; 2000 Aug; 124(8):1135-40. PubMed ID: 10923072
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of blood glucose meters in Australia.
    Cohen M; Boyle E; Delaney C; Shaw J
    Diabetes Res Clin Pract; 2006 Feb; 71(2):113-8. PubMed ID: 16011856
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.