109 related articles for article (PubMed ID: 10195009)
1. The diagnostic X-ray protection characteristics of Ytong, an aerated concrete based building material.
Tsalafoutas IA; Yakoumakis E; Manetou A; Flioni-Vyza A
Br J Radiol; 1998 Sep; 71(849):944-9. PubMed ID: 10195009
[TBL] [Abstract][Full Text] [Related]
2. The diagnostic X-ray protection characteristics of Panelcrete, Aquapanel, Betopan and Gypsoplak Superboard.
Tsalafoutas IA; Yakoumakis E; Sandilos P; Vlahos L; Proukakis C
Br J Radiol; 2001 Apr; 74(880):351-7. PubMed ID: 11387154
[TBL] [Abstract][Full Text] [Related]
3. Shielding requirements for mammography.
Simpkin DJ
Health Phys; 1987 Sep; 53(3):267-79. PubMed ID: 3623916
[TBL] [Abstract][Full Text] [Related]
4. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
Jaradat AK; Biggs PJ
Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of transmission data of diagnostic X rays through concrete using Monte Carlo simulation.
Noto K; Koshida K; Iida H; Fukuda A
Radiat Prot Dosimetry; 2009 Feb; 133(3):144-52. PubMed ID: 19307234
[TBL] [Abstract][Full Text] [Related]
6. Monte Carlo simulation of photon buildup factors for shielding materials in diagnostic x-ray facilities.
Kharrati H; Agrebi A; Karoui MK
Med Phys; 2012 Oct; 39(10):6014-21. PubMed ID: 23039639
[TBL] [Abstract][Full Text] [Related]
7. Attenuation characteristics of MagnaDense high-density concrete at 6, 10 and 15 mv for use in radiotherapy bunker design.
Jones MR; Peet DJ; Horton PW
Health Phys; 2009 Jan; 96(1):67-75. PubMed ID: 19066488
[TBL] [Abstract][Full Text] [Related]
8. Broad beam transmission properties of some common shielding materials for use in diagnostic radiology.
Rossi RP; Ritenour R; Christodoulou E
Health Phys; 1991 Nov; 61(5):601-8. PubMed ID: 1752742
[TBL] [Abstract][Full Text] [Related]
9. Surveyed data for structural shielding calculations of radiographic x-ray installations in Taiwan.
Chen TR; Tyan YS; Chu CH; Wu MC; Tung CJ
Health Phys; 2013 May; 104(5 Suppl 2):S60-7. PubMed ID: 23528275
[TBL] [Abstract][Full Text] [Related]
10. On the primary barrier in diagnostic x-ray shielding.
Dixon RL
Med Phys; 1994 Nov; 21(11):1785-93. PubMed ID: 7891641
[TBL] [Abstract][Full Text] [Related]
11. Derivation of factors for estimating the scatter of diagnostic x-rays from walls and ceiling slabs.
Martin CJ; Sutton DG; Magee J; McVey S; Williams JR; Peet D
J Radiol Prot; 2012 Dec; 32(4):373-96. PubMed ID: 23006642
[TBL] [Abstract][Full Text] [Related]
12. A model for calculating shielding requirements in diagnostic X-ray facilities.
Tsalafoutas IA; Yakoumakis E; Sandilos P
Br J Radiol; 2003 Oct; 76(910):731-7. PubMed ID: 14512334
[TBL] [Abstract][Full Text] [Related]
13. STUDIES ON RADIATION SHIELDING PROPERTIES OF NEWLY DEVELOPED HIGH-DENSITY CONCRETE FOR ADVANCED RADIOTHERAPY FACILITIES.
Kaur A; Sahani G; Mudgal M; Chouhan RK; Srivastava AK; Pawaskar PN
Radiat Prot Dosimetry; 2023 Apr; 199(5):399-409. PubMed ID: 36702799
[TBL] [Abstract][Full Text] [Related]
14. Primary shielding barriers for diagnostic x-ray facilities: a new model.
Dixon RL; Simpkin DJ
Health Phys; 1998 Feb; 74(2):181-9. PubMed ID: 9450588
[TBL] [Abstract][Full Text] [Related]
15. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
Rodgers JE
Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
[TBL] [Abstract][Full Text] [Related]
16. Ulexite-galena intermediate-weight concrete as a novel design for overcoming space and weight limitations in the construction of efficient shields against neutrons and photons.
Aghamiri SM; Mortazavi SM; Razi Z; Mosleh-Shirazi MA; Baradaran-Ghahfarokhi M; Rahmani F; Faeghi F
Radiat Prot Dosimetry; 2013; 154(3):375-80. PubMed ID: 23019599
[TBL] [Abstract][Full Text] [Related]
17. Attenuation properties of diagnostic x-ray shielding materials.
Archer BR; Fewell TR; Conway BJ; Quinn PW
Med Phys; 1994 Sep; 21(9):1499-507. PubMed ID: 7838062
[TBL] [Abstract][Full Text] [Related]
18. Investigation of photon shielding property changes in curing high density concrete.
Marsh MB; Peters C; Rawluk N; Schreiner LJ
Health Phys; 2013 Oct; 105(4):318-25. PubMed ID: 23982607
[TBL] [Abstract][Full Text] [Related]
19. Calculation of conversion coefficients for air kerma to ambient dose equivalent using transmitted spectra of megavoltage X-rays through concrete.
Cordeiro TP; Silva AX
Radiat Prot Dosimetry; 2012 Dec; 152(4):455-62. PubMed ID: 22683619
[TBL] [Abstract][Full Text] [Related]
20. Broad beam attenuation in Leca for 50-140 kVp x-rays.
Wøhni T
Health Phys; 1981 Feb; 40(2):205-9. PubMed ID: 7216798
[No Abstract] [Full Text] [Related]
[Next] [New Search]