These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 10198714)
1. The development of a control method for a total artificial heart using mixed venous oxygen saturation. Nakamura M; Masuzawa T; Tatsumi E; Taenaka Y; Nakamura T; Zhang B; Nakatani T; Takano H; Ohno T Artif Organs; 1999 Mar; 23(3):235-41. PubMed ID: 10198714 [TBL] [Abstract][Full Text] [Related]
2. Control of a total artificial heart using mixed venous oxygen saturation. Nakamura M; Masuzawa T; Tatsumi E; Taenaka Y; Ohno T; Nakamura T; Zhang B; Kakuta Y; Nakatani T; Takano H ASAIO J; 1999; 45(5):460-5. PubMed ID: 10503626 [TBL] [Abstract][Full Text] [Related]
3. Mixed venous oxygen saturation as a promising parameter for physiologic control of total artificial heart. Nakamura M; Homma A; Tatsumi E; Uesho K; Taenaka Y; Masuzawa T; Nakamura T; Zhang B; Kakuta Y; Imada K; Nakatani T; Takano H ASAIO J; 2000; 46(6):761-6. PubMed ID: 11110277 [TBL] [Abstract][Full Text] [Related]
4. Characteristics of mixed venous oxygen saturation and physical activity as parameters for artificial heart control. Ohno T; Masuzawa T; Nakamura M; Tatsumi E; Taenaka Y; Nakatani T; Wakisaka Y; Nishimura T; Takewa Y; Takano H; Fukui Y ASAIO J; 1997; 43(5):M677-81. PubMed ID: 9360132 [TBL] [Abstract][Full Text] [Related]
5. Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: quantification of chronotropic behavior during daily activities and maximal exercise. Lau CP; Tai YT; Leung WH; Leung SK; Li JP; Wong CK; Lee IS; Yerich C; Erickson M Pacing Clin Electrophysiol; 1994 Dec; 17(12 Pt 1):2236-46. PubMed ID: 7885930 [TBL] [Abstract][Full Text] [Related]
6. Positive Correlation Between Regional Cerebral Oxygen Saturation and Mixed Venous Oxygen Saturation During Off-Pump Coronary Artery Bypass Surgery. Guan Z; Liu JJ; Yuan H; Gao YF Respir Care; 2018 Aug; 63(8):988-993. PubMed ID: 29844213 [TBL] [Abstract][Full Text] [Related]
7. Open-loop analysis of circulatory system in awake live animals: relations between mixed venous saturation (SvO2) and hemodynamic parameters. Takatani S Artif Organs; 1993 Feb; 17(2):79-91. PubMed ID: 8439273 [TBL] [Abstract][Full Text] [Related]
8. [Cardiac output control of total artificial heart during exercise--a predictive control method based on objective functions obtained from changes in cardiac output of the natural heart with respect to time]. Maeda K Nihon Kyobu Geka Gakkai Zasshi; 1990 Nov; 38(11):2244-56. PubMed ID: 2280098 [TBL] [Abstract][Full Text] [Related]
9. Utility of an implantable right ventricular oxygen saturation-sensing pacemaker for ambulatory cardiopulmonary monitoring. Lau CP; Tai YT; Lee IS; Erickson M; Yerich C Chest; 1995 Apr; 107(4):1089-94. PubMed ID: 7705121 [TBL] [Abstract][Full Text] [Related]
10. Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake. Nakanishi N; Yoshioka T; Okano Y; Nishimura T Chest; 1993 Aug; 104(2):419-26. PubMed ID: 8339630 [TBL] [Abstract][Full Text] [Related]
11. [Continuous monitoring of mixed venous oxygen saturation during exercise using fiberoptic pulmonary artery catheter]. Nakanishi N; Yoshioka T; Hashizume T; Nonogi H; Okubo S; Shimouchi A; Saito M Kokyu To Junkan; 1990 Aug; 38(8):799-804. PubMed ID: 2218089 [TBL] [Abstract][Full Text] [Related]
12. Continuous in-line monitoring of oxygen delivery to control artificial heart output. Takatani S; Noda H; Takano H; Akutsu T Artif Organs; 1990 Dec; 14(6):458-65. PubMed ID: 2281996 [TBL] [Abstract][Full Text] [Related]
13. Comparison between mixed venous oxygen saturation and thermodilution cardiac output in monitoring patients with severe heart failure treated with milrinone and dobutamine. Nuñez S; Maisel A Am Heart J; 1998 Mar; 135(3):383-8. PubMed ID: 9580093 [TBL] [Abstract][Full Text] [Related]
15. Predictive control by physical activity rate of a total artificial heart during exercise. Maeda K; Chinzei T; Imachi K; Mabuchi K; Abe Y; Yonezawa T; Imanishi K; Fujimasa I; Atsumi K ASAIO Trans; 1988; 34(3):480-4. PubMed ID: 3196549 [TBL] [Abstract][Full Text] [Related]
16. Overshoot in mixed venous oxygen saturation during recovery from supine bicycle exercise in patients with recent myocardial infarction. Sumimoto T; Sugiura T; Takeuchi M; Yuasa F; Iwasaka T; Inada M Chest; 1993 Feb; 103(2):514-20. PubMed ID: 8432146 [TBL] [Abstract][Full Text] [Related]
17. The effect of graded exercise on cardiac output of the Jarvik-7-70 total artificial heart in humans. Everett J; Murray K; Brown V; Watson K; Lowe P; Howanitz EP; Galbraith T; Myerowitz P ASAIO Trans; 1989; 35(3):231-4. PubMed ID: 2597451 [TBL] [Abstract][Full Text] [Related]