These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
274 related articles for article (PubMed ID: 10198737)
1. NC100100, a new echo contrast agent for the assessment of myocardial perfusion--safety and comparison with technetium-99m sestamibi single-photon emission computed tomography in a randomized multicenter study. Binder T; Assayag P; Baer F; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Piérard L; Steg G; Vanoverschelde JL; Van der Wouw P; Meland N; Marelli C; Lindvall K Clin Cardiol; 1999 Apr; 22(4):273-82. PubMed ID: 10198737 [TBL] [Abstract][Full Text] [Related]
2. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators. Marwick TH; Brunken R; Meland N; Brochet E; Baer FM; Binder T; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Pierard L; Vanoverschelde JL; van der Wouw P; Lindvall K J Am Coll Cardiol; 1998 Nov; 32(5):1260-9. PubMed ID: 9809934 [TBL] [Abstract][Full Text] [Related]
3. Comparison of myocardial contrast echocardiography with NC100100 and (99m)Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction. Jucquois I; Nihoyannopoulos P; D'Hondt AM; Roelants V; Robert A; Melin JA; Glass D; Vanoverschelde JL Heart; 2000 May; 83(5):518-24. PubMed ID: 10768900 [TBL] [Abstract][Full Text] [Related]
4. Effect of color coding and subtraction on the accuracy of contrast echocardiography. Pasquet A; Greenberg N; Brunken R; Thomas JD; Marwick TH Int J Cardiol; 1999 Aug; 70(3):223-31. PubMed ID: 10501335 [TBL] [Abstract][Full Text] [Related]
5. Assessment of resting perfusion defects in patients with acute myocardial infarction: comparison of myocardial contrast echocardiography, combined first-pass/delayed contrast-enhanced magnetic resonance imaging and 99mTC-sestamibi SPECT. Lombardo A; Rizzello V; Galiuto L; Natale L; Giordano A; Rebuzzi A; Loperfido F; Crea F; Maseri A Int J Cardiovasc Imaging; 2006; 22(3-4):417-28. PubMed ID: 16496094 [TBL] [Abstract][Full Text] [Related]
6. [Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography in the assessment of myocardial perfusion in patients with acute myocardial infarction]. Olszowska M; Tracz W; Kostkiewicz M; Hlawaty M; Podolec P; Przewłocki T Pol Merkur Lekarski; 2006 Mar; 20(117):282-4. PubMed ID: 16780255 [TBL] [Abstract][Full Text] [Related]
7. The value of myocardial contrast echocardiography compared with SPECT in detecting myocardial perfusion abnormalities in patients with anterior acute myocardial infarction. Olszowska M; Tracz W; Przewłocki T; Kostkiewicz M; Podolec P; Zalewski J; Zmudka K Kardiol Pol; 2004 Jan; 60(1):27-38. PubMed ID: 15004629 [TBL] [Abstract][Full Text] [Related]
9. Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results). Wei K; Crouse L; Weiss J; Villanueva F; Schiller NB; Naqvi TZ; Siegel R; Monaghan M; Goldman J; Aggarwal P; Feigenbaum H; DeMaria A Am J Cardiol; 2003 Jun; 91(11):1293-8. PubMed ID: 12767419 [TBL] [Abstract][Full Text] [Related]
10. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study. Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168 [TBL] [Abstract][Full Text] [Related]
11. Myocardial contrast echocardiography in human beings: correlation of resting perfusion defects to sestamibi single photon emission computed tomography. Meza MF; Mobarek S; Sonnemaker R; Shuler S; Ramee SR; Collins TJ; White CJ; Aristizabal D; Murgo JP; Cheirif J Am Heart J; 1996 Sep; 132(3):528-35. PubMed ID: 8800021 [TBL] [Abstract][Full Text] [Related]
12. Assessment of infarcted myocardium with real time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single photon emission computed tomography. Tousek P; Orban M; Martinoff S; Firschke C Heart; 2005 Dec; 91(12):1568-72. PubMed ID: 15774606 [TBL] [Abstract][Full Text] [Related]
13. Real-time myocardial contrast echocardiography for the detection of stress-induced myocardial ischemia. Comparison with 99mTc-sestamibi single photon emission computed tomography. Dubart AE; Carvalho da Silva KG; Korosoglou G; Bekeredjian R; Hansen A; Hardt S; Rosenberg M; Ferrari N; Hoerig B; Zehelein J; Kuecherer H Z Kardiol; 2004 Nov; 93(11):890-6. PubMed ID: 15568149 [TBL] [Abstract][Full Text] [Related]
14. Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: comparison with quantitative gated Technetium 99m sestamibi single photon emission computed tomography. Dawson D; Rinkevich D; Belcik T; Jayaweera AR; Rafter P; Kaul S; Wei K J Am Soc Echocardiogr; 2003 Nov; 16(11):1171-7. PubMed ID: 14608289 [TBL] [Abstract][Full Text] [Related]
15. Correlation between myocardial perfusion abnormalities detected with intermittent imaging using intravenous perfluorocarbon microbubbles and radioisotope imaging during high-dose dipyridamole stress echo. Ronderos RE; Boskis M; Chung N; Corneli DB; Escudero EM; Ha JW; Charlante C; Rim SJ; Portis M; Fabris N; Camilletti J; Mele AA; Otero F; Porter TR Clin Cardiol; 2002 Mar; 25(3):103-11. PubMed ID: 11890368 [TBL] [Abstract][Full Text] [Related]
16. Assessment of myocardial perfusion in patients with coronary artery disease. Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography. Olszowska M; Kostkiewicz M; Tracz W; Przewlocki T Int J Cardiol; 2003 Jul; 90(1):49-55. PubMed ID: 12821219 [TBL] [Abstract][Full Text] [Related]
17. Long-Term Association of Dipyridamole Stress Myocardial Contrast Echocardiography versus Single-Photon Emission Computed Tomography with Clinical Outcomes in Patients with Known or Suspected Coronary Artery Disease. Karogiannis N; Vamvakidou A; Gurunathan S; Pabla J; Young G; Senior R J Am Soc Echocardiogr; 2018 Aug; 31(8):860-869. PubMed ID: 29861279 [TBL] [Abstract][Full Text] [Related]
18. Comparison between myocardial contrast echocardiography and (99m)technetium sestamibi single photon emission computed tomography determined myocardial viability in predicting hard cardiac events following acute myocardial infarction. Dwivedi G; Janardhanan R; Hayat SA; Lim TK; Senior R Am J Cardiol; 2009 Nov; 104(9):1184-8. PubMed ID: 19840559 [TBL] [Abstract][Full Text] [Related]
19. Quantitative evaluation of myocardial perfusion in patients with revascularized myocardial infarction: comparison between intravenous myocardial contrast echocardiography and 99mTc-sestamibi single photon emission computed tomography. Sieswerda GT; Klein LJ; Kamp O; Aiazian EA; Lepper W; Visser FC; Hanrath P; Visser CA Eur J Echocardiogr; 2004 Jan; 5(1):41-50. PubMed ID: 15113011 [TBL] [Abstract][Full Text] [Related]
20. Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography. Abdelmoneim SS; Bernier M; Dhoble A; Moir S; Hagen ME; Ness SA; Pellikka PA; Abdel-Kader SS; Mulvagh SL Heart Vessels; 2010 Mar; 25(2):121-30. PubMed ID: 20339973 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]