These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 10208197)

  • 1. Routine intraoperative angiography improves the early patency of coronary grafts performed on the beating heart.
    Izzat MB; Khaw KS; Atassi W; Yim AP; Wan S; El-Zufari MH
    Chest; 1999 Apr; 115(4):987-90. PubMed ID: 10208197
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts.
    Kim KB; Lim C; Lee C; Chae IH; Oh BH; Lee MM; Park YB
    Ann Thorac Surg; 2001 Sep; 72(3):S1033-7. PubMed ID: 11565721
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rationale for off-pump coronary revascularization to small branches--angiographic study of 1,283 anastomoses in 408 patients.
    Matsuura K; Kobayashi J; Tagusari O; Bando K; Niwaya K; Nakajima H; Yagihara T; Kitamura S
    Ann Thorac Surg; 2004 May; 77(5):1530-4. PubMed ID: 15111137
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Beating heart coronary artery bypass grafting: results from 402 patients and the usefulness of gastroepiploic artery composite grafting.
    Takemura H; Watanabe G; Takahashi M; Tomita S; Higashidani K
    Jpn J Thorac Cardiovasc Surg; 2003 May; 51(5):173-7. PubMed ID: 12776947
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Graft patency and completeness of revascularization in minimally invasive multivessel coronary artery bypass surgery.
    Zhang L; Fu Y; Gong Y; Zhao H; Wu S; Yang H; Zhang Z; Ling Y
    J Card Surg; 2021 Mar; 36(3):992-997. PubMed ID: 33533054
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermal coronary angiography for intraoperative patency control of arterial and saphenous vein coronary artery bypass grafts: results in 370 patients.
    Falk V; Walther T; Philippi A; Autschbach R; Krieger H; Dalichau H; Mohr FW
    J Card Surg; 1995 Mar; 10(2):147-60. PubMed ID: 7772879
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ten-year experience with off-pump coronary artery bypass grafting: lessons learned from early postoperative angiography.
    Kim KB; Kim JS; Kang HJ; Koo BK; Kim HS; Oh BH; Park YB
    J Thorac Cardiovasc Surg; 2010 Feb; 139(2):256-62. PubMed ID: 20106389
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device.
    Bergsland J; Hol PK; Lingås PS; Lundblad R; Rein KA; Andersen R; Mørk BE; Halvorsen S; Mujanovic E; Kabil E; Svennevig JL; Fosse E
    J Thorac Cardiovasc Surg; 2004 Nov; 128(5):718-23. PubMed ID: 15514599
    [TBL] [Abstract][Full Text] [Related]  

  • 9. One-year coronary bypass graft patency: a randomized comparison between off-pump and on-pump surgery angiographic results of the PRAGUE-4 trial.
    Widimsky P; Straka Z; Stros P; Jirasek K; Dvorak J; Votava J; Lisa L; Budesinsky T; Kolesar M; Vanek T; Brucek P
    Circulation; 2004 Nov; 110(22):3418-23. PubMed ID: 15557371
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Results of the Minimally Invasive Coronary Artery Bypass Grafting Angiographic Patency Study.
    Ruel M; Shariff MA; Lapierre H; Goyal N; Dennie C; Sadel SM; Sohmer B; McGinn JT
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):203-8. PubMed ID: 24183338
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Results of graft patency by immediate angiography in minimally invasive coronary artery surgery.
    Mack MJ; Magovern JA; Acuff TA; Landreneau RJ; Tennison DM; Tinnerman EJ; Osborne JA
    Ann Thorac Surg; 1999 Aug; 68(2):383-9; discussion 389-90. PubMed ID: 10475401
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radial artery grafts vs saphenous vein grafts in coronary artery bypass surgery: a randomized trial.
    Goldman S; Sethi GK; Holman W; Thai H; McFalls E; Ward HB; Kelly RF; Rhenman B; Tobler GH; Bakaeen FG; Huh J; Soltero E; Moursi M; Haime M; Crittenden M; Kasirajan V; Ratliff M; Pett S; Irimpen A; Gunnar W; Thomas D; Fremes S; Moritz T; Reda D; Harrison L; Wagner TH; Wang Y; Planting L; Miller M; Rodriguez Y; Juneman E; Morrison D; Pierce MK; Kreamer S; Shih MC; Lee K
    JAMA; 2011 Jan; 305(2):167-74. PubMed ID: 21224458
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aortocoronary bypass graft patency assessed by coronary computed tomography angiography--unicentric study.
    Luca C; Chistol R; Corciovă F; Iliescu A; Tinică G
    Rev Med Chir Soc Med Nat Iasi; 2014; 118(4):1054-61. PubMed ID: 25581969
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a novel 2 mm internal diameter stainless steel saphenous vein to coronary artery connector: laboratory studies of on-pump and off-pump revascularization.
    Zehr KJ; Hamner CE; Bonilla LF; Berg T; Cornelius R; Hindrichs P; Schaff HV
    Eur J Cardiothorac Surg; 2003 Jun; 23(6):925-33; discussion 933-4. PubMed ID: 12829068
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new technique for intraoperative graft angiography utilizing the radial artery stump.
    Lazzara RR; Kidwell FE; Griffith R
    Heart Surg Forum; 2000; 3(2):123-5; discussion 125-6. PubMed ID: 11074966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative angiography leads to graft revision in coronary artery bypass surgery.
    Hol PK; Lingaas PS; Lundblad R; Rein KA; Vatne K; Smith HJ; Nitter-Hauge S; Fosse E
    Ann Thorac Surg; 2004 Aug; 78(2):502-5; discussion 505. PubMed ID: 15276506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fractional flow reserve-guided coronary artery bypass grafting: can intraoperative physiologic imaging guide decision making?
    Ferguson TB; Chen C; Babb JD; Efird JT; Daggubati R; Cahill JM
    J Thorac Cardiovasc Surg; 2013 Oct; 146(4):824-835.e1. PubMed ID: 23915918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. No-Touch Saphenous Vein Harvesting May Improve Further the Patency of Saphenous Vein Composite Grafts: Early Outcomes and 1-Year Angiographic Results.
    Kim YH; Oh HC; Choi JW; Hwang HY; Kim KB
    Ann Thorac Surg; 2017 May; 103(5):1489-1497. PubMed ID: 27916241
    [TBL] [Abstract][Full Text] [Related]  

  • 19. One-year patency control and risk analysis of eSVS®-mesh-supported coronary saphenous vein grafts.
    Inderbitzin DT; Bremerich J; Matt P; Grapow MT; Eckstein FS; Reuthebuch O
    J Cardiothorac Surg; 2015 Aug; 10():108. PubMed ID: 26253565
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft.
    Waseda K; Ako J; Hasegawa T; Shimada Y; Ikeno F; Ishikawa T; Demura Y; Hatada K; Yock PG; Honda Y; Fitzgerald PJ; Takahashi M
    JACC Cardiovasc Imaging; 2009 May; 2(5):604-12. PubMed ID: 19442948
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.