These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 1021041)

  • 21. STUDIES ON INDOLEPYRUVIC ACID. II. ULTRAVIOLET SPECTROPHOTOMETRY.
    KAPER JM; GEBHARD O; VAN DEN BERG CJ; VELDSTRA H
    Arch Biochem Biophys; 1963 Dec; 103():475-87. PubMed ID: 14099561
    [No Abstract]   [Full Text] [Related]  

  • 22. [Critical study of the application of the Jaffé reaction to the determination of creatinine in blood and urine].
    KAYSER F; MOLITOR A
    Ann Pharm Fr; 1956 Mar; 14(3):197-208. PubMed ID: 13340462
    [No Abstract]   [Full Text] [Related]  

  • 23. An alternative, single-point method for creatinine determination in urine samples with optoelectronic detector. Critical comparison to Jaffé method.
    Lewińska I; Tymecki Ł; Michalec M
    Talanta; 2019 Apr; 195():865-869. PubMed ID: 30625629
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of temperature and wavelength on the measurement of creatinine with the Jaffe procedure.
    Spierto FW; MacNeil ML; Burtis CA
    Clin Biochem; 1979 Feb; 12(1):18-21. PubMed ID: 36238
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Nitromethane interferes in assay of creatinine by the Jaffé reaction.
    De Leacy EA; Brown NN; Clague AE
    Clin Chem; 1989 Aug; 35(8):1772-4. PubMed ID: 2758650
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Formation of a mutagen, 2-amino-1-methyl-6-phenylimidazo[4,5-b]-pyridine (PhIP) in cooked beef, by heating a mixture containing creatinine, phenylalanine and glucose.
    Shioya M; Wakabayashi K; Sato S; Nagao M; Sugimura T
    Mutat Res; 1987; 191(3-4):133-8. PubMed ID: 3627151
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Variation among instruments in interference by cephalosporin in the Jaffé reaction for creatinine.
    Hickman PE; Mather P; Boyne P
    Clin Chem; 1988 Jan; 34(1):215-6. PubMed ID: 3338179
    [No Abstract]   [Full Text] [Related]  

  • 28. Creatinine VII: Determination of saliva creatinine by high-performance liquid chromatography.
    Pu FS; Chiou WL
    J Pharm Sci; 1979 Apr; 68(4):534-5. PubMed ID: 438990
    [No Abstract]   [Full Text] [Related]  

  • 29. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.
    Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C
    Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A procedure increasing the specificity of the Jaffe reaction for the determination of creatine and creatinine in urine and plasma.
    TAUSSKY HH
    Clin Chim Acta; 1956; 1(3):210-24. PubMed ID: 13343522
    [No Abstract]   [Full Text] [Related]  

  • 31. [A kinetic method of determining creatinine using the Jaffé reaction].
    Lipitskaia IIa; Kotkina TI; Tarasov AV; Titov VN
    Lab Delo; 1989; (2):37-42. PubMed ID: 2467057
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Simple high-performance liquid chromatographic method to analyze serum creatinine has several advantages over the Jaffé picric acid reaction as demonstrated with a cimetidine dose response in rhesus monkeys.
    Johns BA; Broten T; Stranieri MT; Holahan MA; Cook JJ
    J Chromatogr B Biomed Sci Appl; 2001 Aug; 759(2):343-8. PubMed ID: 11499488
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Diethylamine prevents precipitation in the alkaline buffer reagent for the kinetic Jaffé determination of serum creatinine.
    Schifreen RS; Sindab J; Bologna D; Cameron C; Burnett RW
    Clin Chem; 1981 Jan; 27(1):196-7. PubMed ID: 7449107
    [No Abstract]   [Full Text] [Related]  

  • 34. Simultaneous determination of creatinine, hypoxanthine and uric acid in biological samples by column-switching liquid chromatography with ultraviolet detection.
    Seki T; Orita Y; Yamaji K; Shinoda A
    J Pharm Biomed Anal; 1997 Jun; 15(9-10):1621-6. PubMed ID: 9226596
    [No Abstract]   [Full Text] [Related]  

  • 35. Creatinine. XIII. Micro high-performance liquid chromatographic assay of creatinine in biological fluids using fixed- or variable-wavelength UV detector.
    Chiou WL; Pu FS; Prueksaritanont T
    J Chromatogr; 1983 Oct; 277():436-8. PubMed ID: 6643635
    [No Abstract]   [Full Text] [Related]  

  • 36. A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.
    Lindbäck B; Bergman A
    Clin Chem; 1989 May; 35(5):835-7. PubMed ID: 2541950
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of serum creatinine by Jaffe method and how to calibrate to eliminate matrix interference problems.
    Chromý V; Rozkosná K; Sedlák P
    Clin Chem Lab Med; 2008; 46(8):1127-33. PubMed ID: 18724810
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Kinetic approach for the enzymic determination of creatinine.
    Perakis N; Wolff CM
    Clin Chem; 1984 Nov; 30(11):1792-6. PubMed ID: 6488523
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Study on the determination of creatinine with the beckman creatinine analyzer 2. Comparison with the Jaffé method in protein-free solution (author's transl)].
    Liappis N
    Klin Padiatr; 1979 Jan; 191(1):66-71. PubMed ID: 569735
    [No Abstract]   [Full Text] [Related]  

  • 40. GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assays.
    Tsikas D; Wolf A; Mitschke A; Gutzki FM; Will W; Bader M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Oct; 878(27):2582-92. PubMed ID: 20462809
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.