These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 10214704)

  • 1. Determination of a calibration factor for the nondestructive assay of Guidant 32P brachytherapy sources.
    Collé R; Zimmerman BE; Soares CG; Coursey BM
    Appl Radiat Isot; 1999 May; 50(5):835-41. PubMed ID: 10214704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chemical digestion and radionuclidic assay of TiNi-encapsulated 32P intravascular brachytherapy sources.
    Collé R
    Appl Radiat Isot; 1999 May; 50(5):811-33. PubMed ID: 10214703
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration of 32P "hot-wall" angioplasty-balloon-catheter sources by liquid-scintillation-spectrometry-based destructive radionuclidic assays.
    Collé R
    Appl Radiat Isot; 2001 Apr; 54(4):611-22. PubMed ID: 11225697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental investigation of dose calibrator response for 125I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass.
    Zimmerman BE; Cessna JT; Dorton JA
    Med Phys; 2002 Jul; 29(7):1547-55. PubMed ID: 12148737
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental dosimetry of a 32P catheter-based endovascular brachytherapy source.
    Piermattei A; Fidanzio A; Perrone F; Azario L; Grimaldi L; Viola P; Capote R
    Phys Med Biol; 2003 Aug; 48(15):2283-96. PubMed ID: 12953898
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose-rate distribution of 32P-glass microspheres for intra-arterial brachytherapy.
    Guimarães CC; Moralles M; Sene FF; Martinelli JR
    Med Phys; 2010 Feb; 37(2):532-9. PubMed ID: 20229861
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation dose from a phosphorous-32 impregnated wire mesh vascular stent.
    Janicki C; Duggan DM; Coffey CW; Fischell DR; Fischell TA
    Med Phys; 1997 Mar; 24(3):437-45. PubMed ID: 9089595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assay of 32P-sodium phosphate using a commercial dose calibrator.
    Zimmer AM; Silverstein EA; Holmes RA
    J Nucl Med; 1976 May; 17(5):404-5. PubMed ID: 1262947
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.
    Esquinas PL; Tanguay J; Gonzalez M; Vuckovic M; Rodríguez-Rodríguez C; Häfeli UO; Celler A
    Med Phys; 2016 Dec; 43(12):6309. PubMed ID: 27908190
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose distribution for endovascular brachytherapy using Ir-192 sources: comparison of Monte Carlo calculations with radiochromic film measurements.
    Sureka CS; Sunny CS; Subbaiah KV; Aruna P; Ganesan S
    Phys Med Biol; 2007 Jan; 52(2):525-37. PubMed ID: 17202631
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dose effects of guide wires for catheter-based intravascular brachytherapy.
    Li XA; Shih R
    Int J Radiat Oncol Biol Phys; 2001 Nov; 51(4):1103-10. PubMed ID: 11704335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetry of 192Ir sources used for endovascular brachytherapy.
    Reynaert N; Van Eijkeren M; Taeymans Y; Thierens H
    Phys Med Biol; 2001 Feb; 46(2):499-516. PubMed ID: 11229729
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Routine calibration of brachytherapy sources with a well-type dose calibrator using standard calibrated sources.
    Niroomand-Rad A
    Radiat Med; 1990; 8(6):238-45. PubMed ID: 2093945
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calibration and characterization of beta-particle sources for intravascular brachytherapy.
    Soares CG; Halpern DG; Wang CK
    Med Phys; 1998 Mar; 25(3):339-46. PubMed ID: 9547501
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations.
    Bohm TD; Mourtada FA; Das RK
    Med Phys; 2001 Aug; 28(8):1770-5. PubMed ID: 11548948
    [TBL] [Abstract][Full Text] [Related]  

  • 16. IVBTMC, a Monte Carlo dose calculation tool for intravascular brachytherapy.
    Chibani O; Li XA
    Med Phys; 2003 Jan; 30(1):44-51. PubMed ID: 12557978
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A segmented 32P source Monte Carlo model to derive AAPM TG-60 dosimetric parameters used for intravascular brachytherapy.
    Mourtada F; Soares CG; Horton JL
    Med Phys; 2004 Mar; 31(3):602-8. PubMed ID: 15070260
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radial dose function of a 90Sr-90Y seed in water and A150: comment on "Calibration and characterization of beta-particle sources for intravascular brachytherapy".
    Asenjo J; Fernández-Varea JM; Sánchez-Reyes A; Wang CK
    Med Phys; 2002 Nov; 29(11):2737-8. PubMed ID: 12462742
    [No Abstract]   [Full Text] [Related]  

  • 19. Comment on "Self-absorption correction for 32P, 198Au, and 188Re stents: dose point kernel calculations versus Monte Carlo".
    Janicki C
    Med Phys; 2002 Feb; 29(2):260-1. PubMed ID: 11865998
    [No Abstract]   [Full Text] [Related]  

  • 20. In-water calibration of PDR 192Ir brachytherapy sources with an NE2571 ionization chamber.
    Reynaert N; Verhaegen F; Thierens H
    Phys Med Biol; 1998 Aug; 43(8):2095-107. PubMed ID: 9725592
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.