These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 10216009)

  • 1. Transcatheter occlusion of the patent ductus arteriosus: use of the retrievable coil device.
    Johnston TA; Stern HJ; O'Laughlin MP
    Catheter Cardiovasc Interv; 1999 Apr; 46(4):434-7. PubMed ID: 10216009
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcatheter closure of patent ductus arteriosus and aorto-pulmonary vessels using non-ferromagnetic Inconel MReye embolization coils.
    Grifka RG; Fenrich AL; Tapio JB
    Catheter Cardiovasc Interv; 2008 Nov; 72(5):691-5. PubMed ID: 18798238
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter coil occlusion of patent ductus arteriosus.
    Lertsapcharoen P; Chottivitayatarakorn P; Benjacholamas V; Thisyakorn C; Pathmanand C; Sueblinvong V
    J Med Assoc Thai; 1999 Mar; 82(3):290-6. PubMed ID: 10410485
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Transcatheter occlusion of the patent ductus arteriosus with detachable coils: immediate results and intermediate-term follow-up].
    Parra-Bravo JR; Acosta-Valdez JL; Girón-Vargas AL; Beirana-Palencia LG; Rodríguez-Hernández L; Estrada-Loza Mde J; Galicia-Galicia JA; Lazo-Cárdenas C; Santillán-Pérez L
    Arch Cardiol Mex; 2005; 75(4):413-20. PubMed ID: 16544765
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Residual patent ductus arteriosus shunting after single Gianturco coil occluding.
    Khowsathit P; Khositseth A; Pongpanich B
    J Med Assoc Thai; 1999 Nov; 82 Suppl 1():S5-9. PubMed ID: 10730510
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Selection of coil for transcatheter closure of small patent ductus arteriosus.
    Lertsapcharoen P; Muangmingsuk S; Chottivittayatarakorn P; Khongphattanayothin A; Thisyakorn C; Sueblinvong V
    J Med Assoc Thai; 2003 Jun; 86 Suppl 2():S208-14. PubMed ID: 12929991
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bioptome-assisted coil occlusion of moderate-large patent ductus arteriosus in infants and small children.
    Kumar RK; Anil SR; Kannan BR; Philip A; Sivakumar K
    Catheter Cardiovasc Interv; 2004 Jun; 62(2):266-71. PubMed ID: 15170724
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A comparative study of Rashkind, Grifka and coil devices in percutaneous closing of patent ductus arteriosus].
    Lázaro Castillo JL; Munayer Calderón J; Aldana Pérez T; San Luis Miranda R; Maza Juárez G; Ramírez Reyes H; Arias Monroy L; Campos Gómez A; Amaya Hernández A
    Arch Inst Cardiol Mex; 2000; 70(2):167-72. PubMed ID: 10932802
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retrograde transcatheter occlusion of patent ductus arteriosus: preliminary experience in Gianturco coil technique without heparinization.
    Liang CD; Wu CJ; Fang CY; Ko SF; Wu YT
    J Invasive Cardiol; 2001 Jan; 13(1):31-5. PubMed ID: 11146685
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Patent ductal arteriosus occlusion by Rashkind umbrella and by detachable coil].
    Mahayni MN; Pépin-Donat M; Saillant D; Poinsot J; Vaillant MC; Chantepie A
    Arch Mal Coeur Vaiss; 2002 May; 95(5):418-24. PubMed ID: 12085739
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Vocal cord paralysis after transcatheter coil embolization of patent ductus arteriosus.
    Liang CD; Ko SF; Huang SC; Huang CF; Niu CK
    Am Heart J; 2003 Aug; 146(2):367-71. PubMed ID: 12891209
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Failures and complications of transcatheter coil occlusion of patent ductus arteriosus].
    Borisov AA; Tsytko AS; Il'in AS; Aleksandrov KIu; Borisova NA
    Vestn Khir Im I I Grek; 2004; 163(3):55-8. PubMed ID: 15317163
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcatheter coil occlusion of persistent ductus arteriosus using detachable steel coils: short-term results.
    Arora R; Verma PK; Trehan V; Passey R; Nigam M; Kalra GS
    Indian Heart J; 1997; 49(1):60-4. PubMed ID: 9130427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcatheter closure in 354 pediatric cases of patent ductus arteriosus using five different devices.
    Zhang Z; Qian M; Wang H; Li Y
    Chin Med J (Engl); 2001 May; 114(5):456-8. PubMed ID: 11780402
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Transcatheter closure of patent ductus arteriosus with Rashkind's occluder. Experience during 3.7 years].
    Ledesma Velasco M; David Gómez F; Alva Espinoza C; Montoya Guerrero SA; Antezana Castro J; Garrido Garduño MH; Argüero Sánchez R
    Arch Inst Cardiol Mex; 1995; 65(4):349-58. PubMed ID: 8561656
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcatheter closure of moderate to large patent ductus arteriosus with the Amplatzer duct occluder.
    Wang JK; Wu MH; Hwang JJ; Chiang FT; Lin MT; Lue HC
    Catheter Cardiovasc Interv; 2007 Mar; 69(4):572-8. PubMed ID: 17323360
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcatheter closure of small-to-large patent ductus arteriosus with different devices: queries and challenges.
    Atiq M; Aslam N; Kazmi KA
    J Invasive Cardiol; 2007 Jul; 19(7):295-8. PubMed ID: 17620673
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcatheter closure of the patent ductus arteriosus with new-generation devices: comparative data and follow-up results.
    Donti A; Formigari R; Bonvicini M; Prandstraller D; Bronzetti G; Picchio FM
    Ital Heart J; 2002 Feb; 3(2):122-7. PubMed ID: 11926010
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Angiographic and hemodynamic predictors for successful outcome of transcatheter occlusion of patent ductus arteriosus in infants less than 8 kilograms.
    Forbes TJ; Harahsheh A; Rodriguez-Cruz E; Morrow WR; Thomas R; Turner D; Vincent JA
    Catheter Cardiovasc Interv; 2004 Jan; 61(1):117-22. PubMed ID: 14696170
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder in children: initial and one-year results].
    Parra-Bravo JR; Cruz-Ramírez A; Toxqui-Terán A; Juan-Martínez E; Chávez-Fernández AA; Lazo-Cárdenas C; Beirana-Palencia L; Estrada-Flores J
    Arch Cardiol Mex; 2009; 79(2):114-20. PubMed ID: 19722381
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.