BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

755 related articles for article (PubMed ID: 10218014)

  • 1. The effect of disinfecting alginate and addition cured silicone rubber impression materials on the physical properties of impressions and resultant casts.
    al-Omari WM; Jones JC; Wood DJ
    Eur J Prosthodont Restor Dent; 1998 Sep; 6(3):103-10. PubMed ID: 10218014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A microbiological investigation following the disinfection of alginate and addition cured silicone rubber impression materials.
    al-Omari WM; Jones JC; Hart P
    Eur J Prosthodont Restor Dent; 1998 Sep; 6(3):97-101. PubMed ID: 10218013
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of immersion disinfection with Perform-ID on alginate, an alginate alternative, an addition-cured silicone and resultant type III gypsum casts.
    Ahmad S; Tredwin CJ; Nesbit M; Moles DR
    Br Dent J; 2007 Jan; 202(1):E1; discussion 36-7. PubMed ID: 17220826
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Factors affecting the accuracy of elastometric impression materials.
    Chen SY; Liang WM; Chen FN
    J Dent; 2004 Nov; 32(8):603-9. PubMed ID: 15476954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Some effects of disinfecting solutions on the properties of alginate impression material and dental stone.
    Boden J; Likeman P; Clark R
    Eur J Prosthodont Restor Dent; 2001; 9(3-4):131-5. PubMed ID: 12192949
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dimensional accuracy of dental casts: influence of tray material, impression material, and time.
    Thongthammachat S; Moore BK; Barco MT; Hovijitra S; Brown DT; Andres CJ
    J Prosthodont; 2002 Jun; 11(2):98-108. PubMed ID: 12087547
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of disinfection on irreversible hydrocolloid and type III gypsum casts.
    Hussain SM; Tredwin CJ; Nesbit M; Moles DR
    Eur J Prosthodont Restor Dent; 2006 Jun; 14(2):50-4. PubMed ID: 16808104
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physical properties of casts prepared from disinfected alginate.
    Abour MA; O'Neilly PJ; Setchell DJ; Pearson GJ
    Eur J Prosthodont Restor Dent; 1996 Jun; 4(2):87-91. PubMed ID: 9181899
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effectiveness of Disinfectants on Antimicrobial and Physical Properties of Dental Impression Materials.
    Demajo JK; Cassar V; Farrugia C; Millan-Sango D; Sammut C; Valdramidis V; Camilleri J
    Int J Prosthodont; 2016; 29(1):63-7. PubMed ID: 26757331
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of different disinfectants on primary impression materials.
    Bock JJ; Fuhrmann RA; Setz J
    Quintessence Int; 2008 Mar; 39(3):e93-8. PubMed ID: 18618030
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Immersion disinfection of irreversible hydrocolloid impressions in pH-adjusted sodium hypochlorite. Part 2: Effect on gypsum casts.
    Hutchings ML; Vandewalle KS; Schwartz RS; Charlton DG
    Int J Prosthodont; 1996; 9(3):223-9. PubMed ID: 8957856
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion.
    Johnson GH; Chellis KD; Gordon GE; Lepe X
    J Prosthet Dent; 1998 Apr; 79(4):446-53. PubMed ID: 9576321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of disinfectant agents on dimensional stability and surface roughness of a tissue conditioner material.
    Khaledi A; Borhanihaghighi Z; Vojdani M
    Indian J Dent Res; 2011; 22(4):499-504. PubMed ID: 22124041
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of a range of disinfectants on the dimensional accuracy of some impression materials.
    Jagger DC; Al Jabra O; Harrison A; Vowles RW; McNally L
    Eur J Prosthodont Restor Dent; 2004 Dec; 12(4):154-60. PubMed ID: 15691188
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of disinfection and a wetting agent on the wettability of addition-polymerized silicone impression materials.
    Milward PJ; Waters MG
    J Prosthet Dent; 2001 Aug; 86(2):165-7. PubMed ID: 11514803
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids.
    Sedda M; Casarotto A; Raustia A; Borracchini A
    J Contemp Dent Pract; 2008 May; 9(4):59-66. PubMed ID: 18473028
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Irreversible hydrocolloids for crown and bridge impressions: effect of different treatments on compatibility of irreversible hydrocolloid impression material with type IV gypsums.
    Eriksson A; Ockert-Eriksson G; Lockowandt P; Lindén LA
    Dent Mater; 1996 Mar; 12(2):74-82. PubMed ID: 9002847
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Disinfection procedures: their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material.
    Rentzia A; Coleman DC; O'Donnell MJ; Dowling AH; O'Sullivan M
    J Dent; 2011 Feb; 39(2):133-40. PubMed ID: 21093528
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The dimensional stability of self-disinfecting alginate impressions compared to various immersion regimes.
    Jones ML; Newcombe RG; Bellis H; Bottomley J
    Angle Orthod; 1990; 60(2):123-8. PubMed ID: 2111646
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Immersion disinfection of irreversible hydrocolloid impressions with sodium hypochlorite. Part II: Effect on gypsum.
    Vandewalle KS; Charlton DG; Schwartz RS; Reagan SE; Koeppen RG
    Int J Prosthodont; 1994; 7(4):315-22. PubMed ID: 7993542
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 38.