3. [Disposable transducers for invasive blood pressure measurement. A test of the dynamic characteristics]. Nielsen LH Ugeskr Laeger; 1994 Aug; 156(31):4454-5. PubMed ID: 8066949 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of blood-pressure transducers. J Med Eng Technol; 1983; 7(2):74-7. PubMed ID: 6864762 [No Abstract] [Full Text] [Related]
5. Measurement of the volume displacement of blood-pressure transducers. Geddes LA; Athens W; Aronson S Med Biol Eng Comput; 1984 Nov; 22(6):613-4. PubMed ID: 6503394 [No Abstract] [Full Text] [Related]
6. A pathway for air entrainment through pressure transducers. Hensler T; Jablonski J; Dhamee S J Clin Monit; 1987 Apr; 3(2):145-7. PubMed ID: 3585435 [No Abstract] [Full Text] [Related]
7. Zero stability of disposable and reusable pressure transducers. Gordon VL; Welch JP; Carley D; Teplick R; Newbower RS Med Instrum; 1987 Apr; 21(2):87-91. PubMed ID: 3614036 [TBL] [Abstract][Full Text] [Related]
8. [Clinical experiences with a new reusable pressure transducer]. Brandt L; Dick W Anaesthesist; 1987 Aug; 36(8):450-4. PubMed ID: 3661958 [TBL] [Abstract][Full Text] [Related]
9. Nosocomial bacteremia associated with contaminated blood pressure transducers: report of an outbreak and a review of the literature. Aduan RP; Iannini PB; Salaki J Am J Infect Control; 1980 May; 8(2):33-40. PubMed ID: 10297850 [No Abstract] [Full Text] [Related]
10. Potential patient risk from vented caps on pressure transducer. McCormick S; Lloyd A; Kapur S Br J Hosp Med (Lond); 2014 Mar; 75(3):176-7. PubMed ID: 24621640 [No Abstract] [Full Text] [Related]
11. Sweep-frequency marker generator for blood pressure transducer testing. Lee AS J Clin Eng; 1983; 8(3):248-52. PubMed ID: 10263340 [TBL] [Abstract][Full Text] [Related]
12. [Basic study of a catheter-tip micromanometer utilizing a single polarization fiber]. Kobayashi K; Miyaji H; Yasuda T; Matsumoto H Iyodenshi To Seitai Kogaku; 1983 Aug; 21(4):256-60. PubMed ID: 6668736 [No Abstract] [Full Text] [Related]
14. High blood pressure during breath-hold diving is not a physiological absurdity. Ferrigno M; Lundgren CE J Appl Physiol (1985); 2010 Nov; 109(5):1567; author reply 1568. PubMed ID: 21060136 [No Abstract] [Full Text] [Related]
16. [A new modification to an indirect method of recording the arterial pressure in the tail artery of rats]. Lapshin DN; Koshelev VB Fiziol Zh SSSR Im I M Sechenova; 1989 Feb; 75(2):282-6. PubMed ID: 2721772 [No Abstract] [Full Text] [Related]
17. Use of Pressure Transducers. Ortega R; Connor C; Kotova F; Deng W; Lacerra C N Engl J Med; 2017 Apr; 376(14):e26. PubMed ID: 28379806 [No Abstract] [Full Text] [Related]
18. Extended use of disposable pressure transducers. A bacteriologic evaluation. Luskin RL; Weinstein RA; Nathan C; Chamberlin WH; Kabins SA JAMA; 1986 Feb; 255(7):916-20. PubMed ID: 3944997 [TBL] [Abstract][Full Text] [Related]
19. Falsely low arterial blood pressure due to transducer slippage. Barringer C; Tilakaratna P Anaesthesia; 2013 Oct; 68(10):1077-8. PubMed ID: 24047299 [No Abstract] [Full Text] [Related]
20. An evaluation of the BD RT2000 reusable transducer system for invasive blood pressure monitoring. Ng KG; Chua TK; Tan C; Cole J; Quickel G Blood Press Monit; 2007 Feb; 12(1):35-43. PubMed ID: 17303986 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]