These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
80 related articles for article (PubMed ID: 1028976)
21. [Determination of the degree of saturation of hemoglobin with oxygen in blood microsamples]. Mosolova LA; Maksimovich NA; Dremza IK Anesteziol Reanimatol; 1990; (5):67-9. PubMed ID: 2288434 [TBL] [Abstract][Full Text] [Related]
22. Detection of pulpal circulation in vitro by pulse oximetry. Noblett WC; Wilcox LR; Scamman F; Johnson WT; Diaz-Arnold A J Endod; 1996 Jan; 22(1):1-5. PubMed ID: 8618078 [TBL] [Abstract][Full Text] [Related]
23. An electrically actuated left ventricular assist device (E-A LVAD) in vivo testing. Aldrich JG; Chambers JA; Daly BD; Migliore JJ; Newgard P; Huffman FN; Norman JC Trans Am Soc Artif Intern Organs; 1974; 20 B():655-9. PubMed ID: 4450313 [No Abstract] [Full Text] [Related]
24. Acute hemodynamic studies of a modified peristaltic bypass type of hear assist device. Takano H; Takagi H; Akutsu T; Farish CA J Thorac Cardiovasc Surg; 1970 Dec; 60(6):796-806. PubMed ID: 5488070 [No Abstract] [Full Text] [Related]
26. Energy transmission through intact skin. Laub DR; Newgard P; Eilers GJ; Ploeg C Surg Forum; 1969; 20():508-9. PubMed ID: 5383132 [No Abstract] [Full Text] [Related]
27. In vitro evaluation of the CeVOX continuous central venous oxygenation monitoring system. Baulig W; Dullenkopf A; Hasenclever P; Schmid ER; Weiss M Anaesthesia; 2008 Apr; 63(4):412-7. PubMed ID: 18336492 [TBL] [Abstract][Full Text] [Related]
28. Instillation of normal saline during endotracheal suctioning: effects on mixed venous oxygen saturation. Kinloch D Am J Crit Care; 1999 Jul; 8(4):231-40; quiz 241-2. PubMed ID: 10392222 [TBL] [Abstract][Full Text] [Related]
29. Electromagnetic power transfer system. Brueschke EE; Hauser R; McNally R; Haklin M; Giuffre V; Mayerhofer K; Welsh T; English K Trans Am Soc Artif Intern Organs; 1981; 27():84-9. PubMed ID: 7331166 [No Abstract] [Full Text] [Related]
30. The clinical value of the haemoglobin concentration analysis (g/L) and the calculation of oxyhaemoglobin saturation (%) in an automatic blood gas analyser (ABL2, Radiometer A/S, Denmark). Sjöberg F; Vegfors M; Lennmarken C Scand J Clin Lab Invest Suppl; 1990; 203():241-5. PubMed ID: 2089617 [TBL] [Abstract][Full Text] [Related]
31. [Effect of the ratio of separation of a gaseous mixture on the calibration of blood-gas pressure meters in lung function laboratories]. Klein J Z Erkr Atmungsorgane Folia Bronchol; 1971; 134(2):267-71. PubMed ID: 5206959 [No Abstract] [Full Text] [Related]
32. Oxygen electrode syringe as an instrument for determining oxygen-hemoglobin dissociation curves. Knight VA J Appl Physiol; 1976 Mar; 40(3):441-2. PubMed ID: 931860 [TBL] [Abstract][Full Text] [Related]
34. STUDIES ON THE LIGHT TRANSMISSION OF NONHEMOLYZED WHOLE BLOOD. DETERMINATION OF OXYGEN SATURATION. ANDERSON NM; SEKELJ P J Lab Clin Med; 1965 Jan; 65():153-66. PubMed ID: 14260689 [No Abstract] [Full Text] [Related]
35. Experiences with a new direct-reading oxygen saturation photometer using ultrasound for hemolyzing the blood. Siggaard-Andersen O Scand J Clin Lab Invest Suppl; 1977; 146():45-50. PubMed ID: 834960 [TBL] [Abstract][Full Text] [Related]
36. Simple, accurate solid-state diode photometer for use in measuring oxygen saturation of whole blood. Fesler R; Clerbaux T Clin Chem; 1974 Sep; 20(9):1135-7. PubMed ID: 4415775 [No Abstract] [Full Text] [Related]