These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 10325152)

  • 1. Characteristics of MA-1 ventilator.
    Fluck RR
    Respir Care; 1977 Aug; 22(8):804, 806. PubMed ID: 10325152
    [No Abstract]   [Full Text] [Related]  

  • 2. Flow measurements with the Bennett MA-1 ventilator.
    Burns TG
    Crit Care Med; 1977; 5(2):120-1. PubMed ID: 265204
    [No Abstract]   [Full Text] [Related]  

  • 3. Interdependence of flowrate, I/E ratio, and expiratory resistance with the Bennett MA-1 ventilator.
    Abbot D; Parenteau S; Demers RR; Saklad M
    Respir Care; 1976 May; 21(5):404-9. PubMed ID: 10315786
    [No Abstract]   [Full Text] [Related]  

  • 4. More on constant-flow and pressure-generating ventilators.
    Sullivan MJ
    Respir Care; 1977 Nov; 22(11):1187. PubMed ID: 10315798
    [No Abstract]   [Full Text] [Related]  

  • 5. Relationships between ventilator waveform and tidal-volume distribution.
    Sullivan M; Saklad M; Demers RR
    Respir Care; 1977 Apr; 22(4):386-93. PubMed ID: 10315784
    [No Abstract]   [Full Text] [Related]  

  • 6. Optimizing patient-ventilator interaction: how we sync about it?
    Tanios MA; Epstein SK
    Crit Care Med; 2008 Feb; 36(2):631-3. PubMed ID: 18216620
    [No Abstract]   [Full Text] [Related]  

  • 7. No square wave from MA-1 ventilator.
    Burns TG
    Respir Care; 1976 Nov; 21(11):1094, 1098. PubMed ID: 10315788
    [No Abstract]   [Full Text] [Related]  

  • 8. Effects of face mask ventilation in apneic patients with a resuscitation ventilator in comparison with a bag-valve-mask.
    von Goedecke A; Wenzel V; Hörmann C; Voelckel WG; Wagner-Berger HG; Zecha-Stallinger A; Luger TJ; Keller C
    J Emerg Med; 2006 Jan; 30(1):63-7. PubMed ID: 16434338
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Resistance to gas-flow of endobronchial tubes.
    Aalto-Setälä M; Heinonen J
    Ann Chir Gynaecol Fenn; 1973; 62(5):271-6. PubMed ID: 4592558
    [No Abstract]   [Full Text] [Related]  

  • 11. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Mechanical interaction between patient and ventilator in biphasic positive airway pressure (BIPAP)--digital and mechanical simulations].
    Maisch S; Reissmann H; Katzenstein O; Böhm S; Füllekrug B; Schulte Am Esch J
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2002 Nov; 37(11):665-73. PubMed ID: 12404143
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detecting ineffective triggering in the expiratory phase in mechanically ventilated patients based on airway flow and pressure deflection: feasibility of using a computer algorithm.
    Chen CW; Lin WC; Hsu CH; Cheng KS; Lo CS
    Crit Care Med; 2008 Feb; 36(2):455-61. PubMed ID: 18091543
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Peak pressures during manual ventilation.
    Turki M; Young MP; Wagers SS; Bates JH
    Respir Care; 2005 Mar; 50(3):340-4. PubMed ID: 15737243
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Theoretical consideration of MA-1 ventilator flow waveform.
    Ichikawa I
    Respir Care; 1977 Aug; 22(8):784-5. PubMed ID: 10315799
    [No Abstract]   [Full Text] [Related]  

  • 16. A pressure-controlled rat ventilator with electronically preset respirations.
    Ordodi VL; Paunescu V; Mic AA; Gabor L; Ionac M; Toma O; Sandesc D; Mic FA
    Artif Organs; 2006 Dec; 30(12):965-8. PubMed ID: 17181839
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Respiratory mechanics derived from signals in the ventilator circuit.
    Lucangelo U; Bernabé F; Blanch L
    Respir Care; 2005 Jan; 50(1):55-65; discussion 65-7. PubMed ID: 15636645
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Patient-ventilator interaction during the triggering phase.
    Racca F; Squadrone V; Ranieri VM
    Respir Care Clin N Am; 2005 Jun; 11(2):225-45. PubMed ID: 15936691
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Battery duration of portable ventilators: effects of control variable, positive end-expiratory pressure, and inspired oxygen concentration.
    Campbell RS; Johannigman JA; Branson RD; Austin PN; Matacia G; Banks GR
    Respir Care; 2002 Oct; 47(10):1173-83. PubMed ID: 12354337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators.
    Lit LM; Doelken P; Mayo PH
    Respir Care; 2004 Sep; 49(9):1022-8. PubMed ID: 15329173
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.