These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 10327102)

  • 21. Comparison of thallium-201 single-photon emission computed tomography and electrocardiographic response during exercise in patients with normal rest electrocardiographic results.
    Nallamothu N; Ghods M; Heo J; Iskandrian AS
    J Am Coll Cardiol; 1995 Mar; 25(4):830-6. PubMed ID: 7884084
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Diagnostic accuracy of dipyridamole technetium 99m-labeled sestamibi myocardial tomography for detection of coronary artery disease.
    Miller DD; Younis LT; Chaitman BR; Stratmann H
    J Nucl Cardiol; 1997; 4(1 Pt 1):18-24. PubMed ID: 9138835
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Diagnostic accuracy of semi-automatic quantitative metrics as an alternative to expert reading of CT myocardial perfusion in the CORE320 study.
    Ostovaneh MR; Vavere AL; Mehra VC; Kofoed KF; Matheson MB; Arbab-Zadeh A; Fujisawa Y; Schuijf JD; Rochitte CE; Scholte AJ; Kitagawa K; Dewey M; Cox C; DiCarli MF; George RT; Lima JAC
    J Cardiovasc Comput Tomogr; 2018; 12(3):212-219. PubMed ID: 29730016
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An incremental evaluation of the diagnostic value of thallium single-photon emission computed tomographic imaging and lung/heart ratio concerning both the presence and extent of coronary artery disease.
    Morise AP
    J Nucl Cardiol; 1995; 2(3):238-45. PubMed ID: 9420794
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease.
    Stewart RE; Schwaiger M; Molina E; Popma J; Gacioch GM; Kalus M; Squicciarini S; al-Aouar ZR; Schork A; Kuhl DE
    Am J Cardiol; 1991 Jun; 67(16):1303-10. PubMed ID: 2042560
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease.
    Chouraqui P; Livschitz S; Sharir T; Wainer N; Wilk M; Moalem I; Baron J
    J Nucl Cardiol; 1998; 5(4):369-77. PubMed ID: 9715981
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A new algorithm for the quantitation of myocardial perfusion SPECT. II: validation and diagnostic yield.
    Sharir T; Germano G; Waechter PB; Kavanagh PB; Areeda JS; Gerlach J; Kang X; Lewin HC; Berman DS
    J Nucl Med; 2000 Apr; 41(4):720-7. PubMed ID: 10768575
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Underestimation of extent and severity of coronary artery disease by dipyridamole stress thallium-201 single-photon emission computed tomographic myocardial perfusion imaging in patients taking antianginal drugs.
    Sharir T; Rabinowitz B; Livschitz S; Moalem I; Baron J; Kaplinsky E; Chouraqui P
    J Am Coll Cardiol; 1998 Jun; 31(7):1540-6. PubMed ID: 9626832
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects.
    Siebelink HM; Natale D; Sinusas AJ; Wackers FJ
    J Nucl Cardiol; 1996; 3(6 Pt 1):483-93. PubMed ID: 8989673
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intracoronary Doppler guide wire versus stress single-photon emission computed tomographic thallium-201 imaging in assessment of intermediate coronary stenoses.
    Joye JD; Schulman DS; Lasorda D; Farah T; Donohue BC; Reichek N
    J Am Coll Cardiol; 1994 Oct; 24(4):940-7. PubMed ID: 7930228
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system.
    Utsunomiya D; Tomiguchi S; Shiraishi S; Yamada K; Honda T; Kawanaka K; Kojima A; Awai K; Yamashita Y
    Ann Nucl Med; 2005 Sep; 19(6):485-9. PubMed ID: 16248385
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: influence of tracer, gender, and acquisition camera.
    Ababneh AA; Sciacca RR; Kim B; Bergmann SR
    J Nucl Cardiol; 2000; 7(6):661-8. PubMed ID: 11144482
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy of Computed Tomographic Angiography and Single-Photon Emission Computed Tomography-Acquired Myocardial Perfusion Imaging for the Diagnosis of Coronary Artery Disease.
    Arbab-Zadeh A; Di Carli MF; Cerci R; George RT; Chen MY; Dewey M; Niinuma H; Vavere AL; Betoko A; Plotkin M; Cox C; Clouse ME; Arai AE; Rochitte CE; Lima JA; Brinker J; Miller JM
    Circ Cardiovasc Imaging; 2015 Oct; 8(10):e003533. PubMed ID: 26467105
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Detection of coronary artery disease: comparison between technetium 99m-labeled sestamibi single-photon emission computed tomography and two-dimensional echocardiography with dipyridamole low-level exercise-stress.
    Cramer MJ; van der Wall EE; Jaarsma W; Verzijlbergen JF; Niemeyer MG; Zwinderman AH; Pauwels EK
    J Nucl Cardiol; 1996; 3(5):389-94. PubMed ID: 8902670
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Magnetic resonance imaging of regional myocardial perfusion in patients with single-vessel coronary artery disease: quantitative comparison with (201)Thallium-SPECT and coronary angiography.
    Keijer JT; van Rossum AC; van Eenige MJ; Bax JJ; Visser FC; Teule JJ; Visser CA
    J Magn Reson Imaging; 2000 Jun; 11(6):607-15. PubMed ID: 10862059
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Assessment of coronary artery disease in women by dobutamine stress echocardiography: comparison with stress thallium-201 single-photon emission computed tomography and exercise electrocardiography.
    Ho YL; Wu CC; Huang PJ; Lin LC; Chieng PU; Chen WJ; Chen MF; Lee YT
    Am Heart J; 1998 Apr; 135(4):655-62. PubMed ID: 9539482
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Arbutamine stress thallium-201 single-photon emission computed tomography using a computerized closed-loop delivery system. Multicenter trial for evaluation of safety and diagnostic accuracy. The International Arbutamine Study Group.
    Kiat H; Iskandrian AS; Villegas BJ; Starling MR; Berman DS
    J Am Coll Cardiol; 1995 Nov; 26(5):1159-67. PubMed ID: 7594027
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Tl-201 myocardial perfusion SPECT: role of nitrate-augmented redistribution.
    Wadhwa SS; Mansberg R; Fernandes VB
    Clin Nucl Med; 1999 Jan; 24(1):1-5. PubMed ID: 9890484
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Identification of viable myocardium in patients with chronic coronary artery disease using rest-redistribution thallium-201 tomography: optimal image analysis.
    Pace L; Perrone-Filardi P; Mainenti P; Cuocolo A; Vezzuto P; Prastaro M; Varrone A; De Luca G; Soricelli A; Betocchi S; Chiariello M; Salvatore M
    J Nucl Med; 1998 Nov; 39(11):1869-74. PubMed ID: 9829573
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison between the end-diastolic images and the summed images of gated 99mTc-sestamibi SPECT perfusion study in detection of coronary artery disease in women.
    Taillefer R; DePuey EG; Udelson JE; Beller GA; Benjamin C; Gagnon A
    J Nucl Cardiol; 1999; 6(2):169-76. PubMed ID: 10327101
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.