375 related articles for article (PubMed ID: 10327315)
1. Left ventricular dysfunction during dobutamine stress echocardiography in patients with syndrome X and positive myocardial perfusion scintigraphy.
Fragasso G; Chierchia SL; Lu C; Dabrowski P; Pagnotta P; Rosano GM
G Ital Cardiol; 1999 Apr; 29(4):383-90. PubMed ID: 10327315
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of post-stress left ventricular dysfunction and its relationship with perfusion abnormalities using gated SPECT in patients with cardiac syndrome X.
Demir H; Kahraman G; Isgoren S; Tan YZ; Kilic T; Berk F
Nucl Med Commun; 2008 Mar; 29(3):208-14. PubMed ID: 18349790
[TBL] [Abstract][Full Text] [Related]
3. Dobutamine-induced hypoperfusion without transient wall motion abnormalities: less severe ischemia or less severe stress?
Elhendy A; Geleijnse ML; Roelandt JR; van Domburg RT; TenCate FJ; Cornel JH; Reijs AE; el-Said GM; Fioretti PM
J Am Coll Cardiol; 1996 Feb; 27(2):323-9. PubMed ID: 8557901
[TBL] [Abstract][Full Text] [Related]
4. Comparison of stress/rest myocardial perfusion tomography, dipyridamole and dobutamine stress echocardiography for the detection of coronary disease in hypertensive patients with chest pain and positive exercise test.
Fragasso G; Lu C; Dabrowski P; Pagnotta P; Sheiban I; Chierchia SL
J Am Coll Cardiol; 1999 Aug; 34(2):441-7. PubMed ID: 10440157
[TBL] [Abstract][Full Text] [Related]
5. Dobutamine stress echocardiography and technetium-99m-tetrofosmin/fluorine 18-fluorodeoxyglucose single-photon emission computed tomography and influence of resting ejection fraction to assess myocardial viability in patients with severe left ventricular dysfunction and healed myocardial infarction.
Rambaldi R; Poldermans D; Bax JJ; Boersma E; Valkema R; Elhendy A; Vletter WB; Fioretti PM; Roelandt JR; Krenning EP
Am J Cardiol; 1999 Jul; 84(2):130-4. PubMed ID: 10426327
[TBL] [Abstract][Full Text] [Related]
6. Comparison of ischemic patterns in myocardial bridge and syndrome X: evaluation by dobutamine stress echocardiography and stress thallium-201 SPECT.
Ho YL; Wu CC; Yen RF; Hung SR; Chen MF; Huang PJ
J Formos Med Assoc; 2001 Feb; 100(2):83-8. PubMed ID: 11393106
[TBL] [Abstract][Full Text] [Related]
7. Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities.
Takeuchi M; Otani S; Weinert L; Spencer KT; Lang RM
J Am Soc Echocardiogr; 2006 Mar; 19(3):294-9. PubMed ID: 16500492
[TBL] [Abstract][Full Text] [Related]
8. Comparison of dobutamine echocardiography, dobutamine sestamibi, and rest-redistribution thallium-201 single-photon emission computed tomography for determining contractile reserve and myocardial ischemia in ischemic cardiomyopathy.
Amanullah AM; Chaudhry FA; Heo J; Galatro K; Dourdoufis P; Brozena S; Narula J; Iskandrian AE
Am J Cardiol; 1999 Sep; 84(6):626-31. PubMed ID: 10498129
[TBL] [Abstract][Full Text] [Related]
9. The grade of worsening of regional function during dobutamine stress echocardiography predicts the extent of myocardial perfusion abnormalities.
Elhendy A; van Domburg RT; Bax JJ; Poldermans D; Nierop PR; Geleijnse ML; Roelandt JR
Heart; 2000 Jan; 83(1):35-9. PubMed ID: 10618333
[TBL] [Abstract][Full Text] [Related]
10. Noninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mTc sestamibi single-photon emission CT.
Elhendy A; van Domburg RT; Bax JJ; Nierop PR; Geleijnse ML; Ibrahim MM; Roelandt JR
Chest; 1998 Oct; 114(4):1097-104. PubMed ID: 9792583
[TBL] [Abstract][Full Text] [Related]
11. [Usefulness of dobutamine stress echocardiography in qualification of patients to angioplasty of infarct related artery].
Michałek P; Klisiewicz A; Witkowski A; Ruzyłło W; Rydlewska-Sadowska W
Pol Arch Med Wewn; 1999 Dec; 102(6):1055-62. PubMed ID: 11072541
[TBL] [Abstract][Full Text] [Related]
12. Mechanisms of regional wall motion abnormalities in contrast-enhanced dobutamine stress echocardiography.
Heinicke N; Benesch B; Kaiser T; Debl K; Segmüller M; Schönberger J; Marienhagen J; Eilles C; Riegger GA; Holmer S; Luchner A
Clin Res Cardiol; 2006 Dec; 95(12):650-6. PubMed ID: 16998740
[TBL] [Abstract][Full Text] [Related]
13. Identification of hibernating myocardium: a comparison between dobutamine echocardiography and study of perfusion and metabolism in patients with severe left ventricular dysfunction.
Mariani MA; Palagi C; Donatelli F; Mengozzi G; Biadi O; Vanoli G; Landoni C; Paolini G; Lucignani G; Fazio F
Am J Card Imaging; 1995 Jan; 9(1):1-8. PubMed ID: 7894227
[TBL] [Abstract][Full Text] [Related]
14. Differential effects of dobutamine versus treadmill exercise on left ventricular volume and wall stress.
Mehrotra P; Labib SB; Schick EC
J Am Soc Echocardiogr; 2012 Aug; 25(8):911-8. PubMed ID: 22658422
[TBL] [Abstract][Full Text] [Related]
15. Comparison of dobutamine stress echocardiography and technetium-99m sestamibi single-photon emission tomography for the diagnosis of coronary artery disease in hypertensive patients with and without left ventricular hypertrophy.
Elhendy A; Geleijnse ML; van Domburg RT; Bax JJ; Nierop PR; Beerens SA; Valkema R; Krenning EP; Mohsen Ibrahim M; Roelandt JR
Eur J Nucl Med; 1998 Jan; 25(1):69-78. PubMed ID: 9396877
[TBL] [Abstract][Full Text] [Related]
16. Prognostic value of myocardial viability in medically treated patients with global left ventricular dysfunction early after an acute uncomplicated myocardial infarction: a dobutamine stress echocardiographic study.
Picano E; Sicari R; Landi P; Cortigiani L; Bigi R; Coletta C; Galati A; Heyman J; Mattioli R; Previtali M; Mathias W; Dodi C; Minardi G; Lowenstein J; Seveso G; Pingitore A; Salustri A; Raciti M
Circulation; 1998 Sep; 98(11):1078-84. PubMed ID: 9736594
[TBL] [Abstract][Full Text] [Related]
17. Feasibility of myocardial performance index for evaluation of left ventricular function during dobutamine stress echocardiography before and after coronary artery bypass grafting.
Hashemi N; Samad BA; Hedman A; Brodin LÅ; Alam M
Echocardiography; 2014 Sep; 31(8):989-95. PubMed ID: 24354348
[TBL] [Abstract][Full Text] [Related]
18. Detection of viable myocardium: comparison of dobutamine echocardiography and echocardiography after hyperbaric oxygenation.
Veselka J; Mates M; Dolezal V
Undersea Hyperb Med; 1999; 26(1):9-13. PubMed ID: 10353179
[TBL] [Abstract][Full Text] [Related]
19. Accuracy of dobutamine technetium 99m sestamibi SPECT imaging for the diagnosis of single-vessel coronary artery disease: comparison with echocardiography.
Elhendy A; van Domburg RT; Bax JJ; Poldermans D; Sozzi FB; Roelandt JR
Am Heart J; 2000 Feb; 139(2 Pt 1):224-30. PubMed ID: 10650294
[TBL] [Abstract][Full Text] [Related]
20. Abnormal BMIPP uptake in chronically dysfunctional myocardial segments: correlation with contractile response to low-dose dobutamine.
Hambÿe AS; Vaerenberg MM; Dobbeleir AA; Van den Heuvel PA; Franken PR
J Nucl Med; 1998 Nov; 39(11):1845-50. PubMed ID: 9829568
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]