These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 10343211)

  • 1. Prospective comparative evaluation of video US endoscope.
    Chak A; Isenberg G; Mallery S; Van Dam J; Cooper GS; Sivak MV
    Gastrointest Endosc; 1999 Jun; 49(6):695-9. PubMed ID: 10343211
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Initial experience with an electronic radial array echoendoscope: randomized comparison with a mechanical sector scanning echoendoscope in humans.
    Anderson MA; Scheiman JM
    Gastrointest Endosc; 2002 Oct; 56(4):573-7. PubMed ID: 12297781
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Newly-developed, forward-viewing echoendoscope: a comparative pilot study to the standard echoendoscope in the imaging of abdominal organs and feasibility of endoscopic ultrasound-guided interventions.
    Iwashita T; Nakai Y; Lee JG; Park DH; Muthusamy VR; Chang KJ
    J Gastroenterol Hepatol; 2012 Feb; 27(2):362-7. PubMed ID: 21916990
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Forward-viewing versus oblique-viewing echoendoscopes in transluminal drainage of pancreatic fluid collections: a multicenter, randomized, controlled trial.
    Voermans RP; Ponchon T; Schumacher B; Fumex F; Bergman JJ; Larghi A; Neuhaus H; Costamagna G; Fockens P
    Gastrointest Endosc; 2011 Dec; 74(6):1285-93. PubMed ID: 21981813
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Forward-viewing echoendoscope versus standard echoendoscope for endoscopic ultrasound-guided tissue acquisition of solid lesions: a randomized, multicenter study.
    Larghi A; Ibrahim M; Fuccio L; Lekkerkerker S; Eisendrath P; Frazzoni L; Fockens P; La Marca M; van Hooft JE; Deviere J; Costamagna G
    Endoscopy; 2019 May; 51(5):444-451. PubMed ID: 30497087
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Newly developed all in one EUS system: one cart system, forward-viewing optics type 360 degrees electronic radial array echoendoscope and oblique-viewing type convex array echoendoscope.
    Akahoshi K; Tanaka T; Matsui N; Kubokawa M; Motomura Y; Honda K; Murata A; Ouchi J; Kimura M; Endo S
    Fukuoka Igaku Zasshi; 2007 Mar; 98(3):82-9. PubMed ID: 17461033
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Forward-viewing linear echoendoscope: a new option in the endoscopic ultrasound armamentarium (with video).
    Fuccio L; Attili F; Larghi A
    J Hepatobiliary Pancreat Sci; 2015 Jan; 22(1):27-34. PubMed ID: 25345848
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new radial mechanical puncture echoendoscope: prospective comparison with standard linear and radial echoendoscopes in assessment of focal pancreatic lesions.
    Brand B; Ponnudurai R; Ryozawa S; Mendes KL; Yang AM; Bohnacker S; Seitz U; Seewald S; Soehendra N
    Gastrointest Endosc; 2002 Feb; 55(2):249-54. PubMed ID: 11818934
    [TBL] [Abstract][Full Text] [Related]  

  • 9. EUS-guided, fine-needle aspiration biopsy using a new mechanical scanning puncture echoendoscope.
    Binmoeller KF; Brand B; Thul R; Rathod V; Soehendra N
    Gastrointest Endosc; 1998 May; 47(5):335-40. PubMed ID: 9609423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Forward-viewing versus oblique-viewing echoendoscopes in the diagnosis of upper GI subepithelial lesions with EUS-guided FNA: a prospective, randomized, crossover study.
    Matsuzaki I; Miyahara R; Hirooka Y; Funasaka K; Ohno E; Nakamura M; Kawashima H; Nukaga A; Shimoyama Y; Goto H
    Gastrointest Endosc; 2015 Aug; 82(2):287-95. PubMed ID: 25816723
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EUS compared with endoscopy plus transabdominal US in the initial diagnostic evaluation of patients with upper abdominal pain.
    Chang KJ; Erickson RA; Chak A; Lightdale C; Chen YK; Binmoeller KF; Albers GC; Chen WP; McLaren CE; Sivak MV; Lee JG; Isenberg GA; Wong RC
    Gastrointest Endosc; 2010 Nov; 72(5):967-74. PubMed ID: 20650452
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of the front-view forward-array echoendoscope to evaluate right colonic subepithelial lesions.
    Nguyen-Tang T; Shah JN; Sanchez-Yague A; Binmoeller KF
    Gastrointest Endosc; 2010 Sep; 72(3):606-10. PubMed ID: 20561620
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pancreatic pseudocyst drainage performed with a new prototype forward-viewing linear echoendoscope.
    Fernández de Castro C; Cañete Á; Sanz de Villalobos E; Ferreiro R; Albillos Martínez A; Vázquez Sequeiros E
    Rev Esp Enferm Dig; 2016 Oct; 108(10):680-683. PubMed ID: 27650893
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial evaluation of the forward-viewing echoendoscope prototype for performing fine-needle aspiration, Tru-cut biopsy, and celiac plexus neurolysis.
    Eloubeidi MA
    J Gastroenterol Hepatol; 2011 Jan; 26(1):63-7. PubMed ID: 21175795
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of a phased vector array US catheter for EUS.
    Shamoun DK; Norton ID; Levy MJ; Vazquez-Sequeiros E; Wiersema MJ
    Gastrointest Endosc; 2002 Sep; 56(3):430-5. PubMed ID: 12196790
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Increased rate of complete EUS staging of patients with esophageal cancer using the nonoptical, wire-guided echoendoscope.
    Mallery S; Van Dam J
    Gastrointest Endosc; 1999 Jul; 50(1):53-7. PubMed ID: 10385722
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An electronic radial scanning echoendoscope is superior to a mechanical radial scanning echoendoscope in ultrasound image quality for gastrointestinal tract and pancreaticobiliary lesions.
    Hikichi T; Irisawa A; Takagi T; Shibukawa G; Wakatsuki T; Imamura H; Takahashi Y; Sato A; Sato M; Ikeda T; Suzuki R; Watanabe K; Nakamura J; Ohira H; Obara K
    Fukushima J Med Sci; 2010 Dec; 56(2):99-106. PubMed ID: 21502709
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single-step EUS-guided pancreatic pseudocyst drainage using a large channel linear array echoendoscope and cystotome: results in 11 patients.
    Ahlawat SK; Charabaty-Pishvaian A; Jackson PG; Haddad NG
    JOP; 2006 Nov; 7(6):616-24. PubMed ID: 17095841
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endosonographic diagnosis of submucosal upper gastrointestinal tract lesions and large fold gastropathies by catheter ultrasound probe.
    Buscarini E; Stasi MD; Rossi S; Silva M; Giangregorio F; Adriano Z; Buscarini L
    Gastrointest Endosc; 1999 Feb; 49(2):184-91. PubMed ID: 9925696
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prospective evaluation of balloon-sheathed catheter US system.
    Schembre D; Chak A; Stevens P; Isenberg G; Sivak MV; Lightdale CJ
    Gastrointest Endosc; 2001 Jun; 53(7):758-63. PubMed ID: 11375584
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.