These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 10343260)

  • 1. Percutaneous balloon fenestration and stenting for life-threatening ischemic complications in patients with acute aortic dissection.
    Slonim SM; Miller DC; Mitchell RS; Semba CP; Razavi MK; Dake MD
    J Thorac Cardiovasc Surg; 1999 Jun; 117(6):1118-26. PubMed ID: 10343260
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aortic dissection: percutaneous management of ischemic complications with endovascular stents and balloon fenestration.
    Slonim SM; Nyman U; Semba CP; Miller DC; Mitchell RS; Dake MD
    J Vasc Surg; 1996 Feb; 23(2):241-51; discussion 251-3. PubMed ID: 8637101
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous management of ischemic complications in patients with type-B aortic dissection.
    Vedantham S; Picus D; Sanchez LA; Braverman A; Moon MR; Sundt T; Kim P; Rubin B; Sicard GA
    J Vasc Interv Radiol; 2003 Feb; 14(2 Pt 1):181-94. PubMed ID: 12582186
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic intimal dehiscence: a complication of percutaneous balloon fenestration for aortic dissection.
    Lookstein RA; Mitty H; Falk A; Guller J; Nowakowski FS
    J Vasc Interv Radiol; 2001 Nov; 12(11):1347-50. PubMed ID: 11698636
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Ischemic complications in aortic dissection--percutaneous treatment with balloon fenestration and stent implantation].
    Manke C; Strotzer M; Seitz J; Lenhart M; Aebert H; Kasprzak P; Kaiser B; Feuerbach S
    Rofo; 1999 Feb; 170(2):198-204. PubMed ID: 10101362
    [TBL] [Abstract][Full Text] [Related]  

  • 6. True lumen obliteration in complicated aortic dissection: endovascular treatment.
    Slonim SM; Nyman UR; Semba CP; Miller DC; Mitchell RS; Dake MD
    Radiology; 1996 Oct; 201(1):161-6. PubMed ID: 8816538
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The dissected aorta: percutaneous treatment of ischemic complications--principles and results.
    Williams DM; Lee DY; Hamilton BH; Marx MV; Narasimham DL; Kazanjian SN; Prince MR; Andrews JC; Cho KJ; Deeb GM
    J Vasc Interv Radiol; 1997; 8(4):605-25. PubMed ID: 9232578
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relationship of intimal flap position to endovascular treatment of malperfusion syndromes in aortic dissection.
    Gaxotte V; Cocheteux B; Haulon S; Vincentelli A; Lions C; Koussa M; Willoteaux S; Asseman P; Prat A; Beregi JP
    J Endovasc Ther; 2003 Aug; 10(4):719-27. PubMed ID: 14533972
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A single-center experience treating renal malperfusion after aortic dissection with central aortic fenestration and renal artery stenting.
    Barnes DM; Williams DM; Dasika NL; Patel HJ; Weder AB; Stanley JC; Deeb GM; Upchurch GR
    J Vasc Surg; 2008 May; 47(5):903-910; discussion 910-1. PubMed ID: 18455638
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Percutaneous balloon fenestration and stent placement for lower limb ischemia complicated with type B aortic dissection.
    Yamaguchi M; Sugimoto K; Tsuji Y; Ozaki N; Tsurusaki M; Taniguchi T; Zamora CA; Okita Y; Sugimura K
    Radiat Med; 2006 Apr; 24(3):233-7. PubMed ID: 16875314
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Endovascular Therapy for Nonischemic vs Ischemic Complicated Acute Type B Aortic Dissection.
    Eleshra A; Kölbel T; Panuccio G; Rohlffs F; Debus ES; Tsilimparis N
    J Endovasc Ther; 2020 Feb; 27(1):145-152. PubMed ID: 31797707
    [No Abstract]   [Full Text] [Related]  

  • 12. Relief of acute lower limb ischemia with percutaneous fenestration of intimal flap in a patient with type III aortic dissection--a case report.
    Kato N; Sakuma H; Takeda K; Hirano T; Nakagawa T
    Angiology; 1993 Sep; 44(9):755-9. PubMed ID: 8357106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Long-term outcomes of surgical aortic fenestration for complicated acute type B aortic dissections.
    Trimarchi S; Jonker FH; Muhs BE; Grassi V; Righini P; Upchurch GR; Rampoldi V
    J Vasc Surg; 2010 Aug; 52(2):261-6. PubMed ID: 20573474
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endovascular stent placement for acute type-B aortic dissection with malperfusion--an intentional surgical delay and a possible 'bridging therapy'.
    Fujita W; Daitoku K; Taniguchi S; Fukuda I
    Interact Cardiovasc Thorac Surg; 2009 Feb; 8(2):266-8. PubMed ID: 19010940
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endovascular Fenestration/Stenting First Followed by Delayed Open Aortic Repair for Acute Type A Aortic Dissection With Malperfusion Syndrome.
    Yang B; Rosati CM; Norton EL; Kim KM; Khaja MS; Dasika N; Wu X; Hornsby WE; Patel HJ; Deeb GM; Williams DM
    Circulation; 2018 Nov; 138(19):2091-2103. PubMed ID: 30474418
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of endovascular techniques for the treatment of complications of aortic dissection.
    Walker PJ; Dake MD; Mitchell RS; Miller DC
    J Vasc Surg; 1993 Dec; 18(6):1042-51. PubMed ID: 8264033
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Management of vital organ malperfusion in acute aortic dissection: proposal of a mechanism-specific approach.
    Shiiya N; Matsuzaki K; Kunihara T; Murashita T; Matsui Y
    Gen Thorac Cardiovasc Surg; 2007 Mar; 55(3):85-90. PubMed ID: 17447505
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Percutaneous interventions for treating ischemic complications of aortic dissection.
    Chavan A; Rosenthal H; Luthe L; Pfingsten S; Kutschka I; Easo J; Piepenbrock S; Dapunt O; Haverich A; Galanski M
    Eur Radiol; 2009 Feb; 19(2):488-94. PubMed ID: 18690447
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-term results of percutaneous management of malperfusion in acute type B aortic dissection: implications for thoracic aortic endovascular repair.
    Patel HJ; Williams DM; Meerkov M; Dasika NL; Upchurch GR; Deeb GM
    J Thorac Cardiovasc Surg; 2009 Aug; 138(2):300-8. PubMed ID: 19619770
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fenestration revisited. A safe and effective procedure for descending aortic dissection.
    Elefteriades JA; Hammond GL; Gusberg RJ; Kopf GS; Baldwin JC
    Arch Surg; 1990 Jun; 125(6):786-90. PubMed ID: 2346378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.