These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 10347356)

  • 21. Stress distribution of abutments and base displacement with precision attachment- and telescopic crown-retained removable partial dentures.
    Saito M; Miura Y; Notani K; Kawasaki T
    J Oral Rehabil; 2003 May; 30(5):482-7. PubMed ID: 12752927
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical performance of cements as luting agents for telescopic double crown-retained removable partial and complete overdentures.
    Behr M; Kolbeck C; Lang R; Hahnel S; Dirschl L; Handel G
    Int J Prosthodont; 2009; 22(5):479-87. PubMed ID: 20095198
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical retention force development of double crowns.
    Bayer S; Stark H; Gölz L; Keilig L; Kraus D; Hansen A; Enkling N
    Clin Oral Investig; 2012 Apr; 16(2):407-11. PubMed ID: 21360104
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Changes in retention of various telescope crown assemblies over long-term use.
    Ohkawa S; Okane H; Nagasawa T; Tsuru H
    J Prosthet Dent; 1990 Aug; 64(2):153-8. PubMed ID: 2202814
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Telescopic crown-retained removable partial dentures: review and case report.
    Beschnidt SM; Chitmongkolsuk S; Prull R
    Compend Contin Educ Dent; 2001 Nov; 22(11):927-8, 929-32, 934 passim; quiz 942. PubMed ID: 11803658
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system.
    Al-Ghafli SA; Michalakis KX; Hirayama H; Kang K
    J Prosthet Dent; 2009 Sep; 102(3):140-7. PubMed ID: 19703620
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of retentive forces between telescopic crowns made of poly(ether ether ketone) and type 4 gold alloy.
    Nakamura M; Tanaka A; Tasaka A; Yoshinari M; Takemoto S; Yamashita S
    Dent Mater J; 2021 Jan; 40(1):129-135. PubMed ID: 32863374
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The Use of Telescopic Crowns in Removable Partial Denture Treatment for Patients with Severe Periodontal Disease: Two Patient Case History Reports.
    Cho JH; Cho SA
    Int J Prosthodont; 2016; 29(2):175-8. PubMed ID: 26929960
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Double-Crown Prosthesis Retention Using Polyetherketoneketone (PEKK): An In Vitro Study.
    Igarashi K; Katagiri H; Abou-Ayash S; Schimmel M; Afrashtehfar KI
    J Prosthodont; 2023 Feb; 32(2):154-161. PubMed ID: 35343624
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Removable four implant-supported mandibular overdentures rigidly retained with telescopic crowns or milled bars: a 3-year prospective study.
    Krennmair G; Sütö D; Seemann R; Piehslinger E
    Clin Oral Implants Res; 2012 Apr; 23(4):481-8. PubMed ID: 21504478
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analysis of veneer failure of removable prosthodontics.
    Hahnel S; Bürgers R; Rosentritt M; Handel G; Behr M
    Gerodontology; 2012 Jun; 29(2):e1125-8. PubMed ID: 21054505
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The evaluation of the removal forces on the conus crowned telescopic prostheses with the finite element analysis (FEA).
    Güngör MA; Artunç C; Sonugelen M; Toparli M
    J Oral Rehabil; 2002 Nov; 29(11):1069-75. PubMed ID: 12453261
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Technical failure rates of double crown-retained removable partial dentures.
    Behr M; Hofmann E; Rosentritt M; Lang R; Handel G
    Clin Oral Investig; 2000 Jun; 4(2):87-90. PubMed ID: 11218506
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of clasp retention forces and abrasion on different cast crowns.
    Jiang N; Gao WM; Zhang H; Zheng DX
    J Prosthet Dent; 2014 Jun; 111(6):493-8. PubMed ID: 24423460
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study.
    Stober T; Bermejo JL; Beck-Mussoter J; Seche AC; Lehmann F; Koob J; Rammelsberg P
    Int J Prosthodont; 2012; 25(3):209-16. PubMed ID: 22545249
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of the effects of friction varnish and electroforming on the retention of telescopic crowns.
    Özyemişci-Cebeci N; Yavuzyilmaz H
    J Prosthet Dent; 2013 Jun; 109(6):392-6. PubMed ID: 23763784
    [TBL] [Abstract][Full Text] [Related]  

  • 37. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures.
    Türk PE; Geckili O; Türk Y; Günay V; Bilgin T
    Int J Oral Maxillofac Implants; 2014; 29(5):1106-13. PubMed ID: 25216136
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Case reports of removable partial dentures with crown and sleeve-coping telescopic retainers].
    Yamauchi M; Kawano J
    Gifu Shika Gakkai Zasshi; 1985 Feb; 12(1):78-86. PubMed ID: 3897358
    [No Abstract]   [Full Text] [Related]  

  • 39. Frictional telescopic crowns in severely reduced dentitions: a 5-year clinical outcome study.
    Szentpetery V; Lautenschlager C; Setz JM
    Int J Prosthodont; 2012; 25(3):217-20. PubMed ID: 22545250
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments.
    Kamel A; Yamazaki T; Murakami N; Lyu H; Komine K; Badr A; Fekry G; Takahashi H; Wakabayashi N
    Dent Mater J; 2023 May; 42(3):336-342. PubMed ID: 36709987
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.