These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
214 related articles for article (PubMed ID: 10351967)
21. Phantom evaluation of scatter and attenuation correction in thallium-201/technetium-99m acquisition in myocardial perfusion single-photon emission computed tomography. Ohyama Y; Tomiguchi S; Kira T; Kojima A; Matsumoto M; Nishi J; Katsuda N; Takahashi M; Motomura N Radiat Med; 2001; 19(2):81-7. PubMed ID: 11383647 [TBL] [Abstract][Full Text] [Related]
22. Attenuation correction of myocardial SPECT perfusion images with low-dose CT: evaluation of the method by comparison with perfusion PET. Fricke E; Fricke H; Weise R; Kammeier A; Hagedorn R; Lotz N; Lindner O; Tschoepe D; Burchert W J Nucl Med; 2005 May; 46(5):736-44. PubMed ID: 15872344 [TBL] [Abstract][Full Text] [Related]
23. Effect of attenuation correction on normal (99)mTc-MIBI myocardial perfusion scintigrams acquired with a hybrid SPECT/CT camera. Płachcińska A; Siennicki J; Kovacevic-Kuśmierek K; Bieńkiewicz M; Kuśmierek J Nucl Med Rev Cent East Eur; 2008; 11(2):59-66. PubMed ID: 19585456 [TBL] [Abstract][Full Text] [Related]
24. Attenuation correction for myocardial perfusion imaging. A comparison between SPECT and PET imaging by polar map analysis. Graf S; Khorsand A; Stix G; Nekolla S; Becherer A; Kletter K; Dudczak R; Sochor H; Maurer G; Porenta G Nuklearmedizin; 2006; 45(4):171-6. PubMed ID: 16964343 [TBL] [Abstract][Full Text] [Related]
25. Monte Carlo-based down-scatter correction of SPECT attenuation maps. Bokulić T; Vastenhouw B; de Jong HW; van Dongen AJ; van Rijk PP; Beekman FJ Eur J Nucl Med Mol Imaging; 2004 Aug; 31(8):1173-81. PubMed ID: 15034678 [TBL] [Abstract][Full Text] [Related]
26. A modified TEW approach to scatter correction for In-111 and Tc-99m dual-isotope small-animal SPECT. Prior P; Timmins R; Petryk J; Strydhorst J; Duan Y; Wei L; Glenn Wells R Med Phys; 2016 Oct; 43(10):5503. PubMed ID: 27782731 [TBL] [Abstract][Full Text] [Related]
27. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration. Goetze S; Brown TL; Lavely WC; Zhang Z; Bengel FM J Nucl Med; 2007 Jul; 48(7):1090-5. PubMed ID: 17574985 [TBL] [Abstract][Full Text] [Related]
28. Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease. Lee DS; So Y; Cheon GJ; Kim KM; Lee MM; Chung JK; Lee MC J Nucl Med; 2000 May; 41(5):852-9; discussion 860-2. PubMed ID: 10809202 [TBL] [Abstract][Full Text] [Related]
29. Clinical usefulness of attenuation and scatter correction in Tl-201 SPECT studies using coronary angiography as a reference. Velidaki A; Perisinakis K; Koukouraki S; Koutsikos J; Vardas P; Karkavitsas N Hellenic J Cardiol; 2007; 48(4):211-7. PubMed ID: 17715612 [TBL] [Abstract][Full Text] [Related]
30. Attenuation compensation in 99mTc SPECT brain imaging: a comparison of the use of attenuation maps derived from transmission versus emission data in normal scans. Licho R; Glick SJ; Xia W; Pan TS; Penney BC; King MA J Nucl Med; 1999 Mar; 40(3):456-63. PubMed ID: 10086711 [TBL] [Abstract][Full Text] [Related]
31. [Combined scatter and attenuation correction for 201Tl myocardial perfusion SPECT using OS-EM algorithm]. Matsuoka S; Shinohara H; Yamamoto T; Niio Y; Shima H; Yamada M; Hasebe S; Uchiyama K; Kuniyasu Y; Takahashi M; Yokoi T Nihon Igaku Hoshasen Gakkai Zasshi; 1998 Nov; 58(13):751-7. PubMed ID: 9866992 [TBL] [Abstract][Full Text] [Related]
32. Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT. El Fakhri G; Buvat I; Benali H; Todd-Pokropek A; Di Paola R J Nucl Med; 2000 Aug; 41(8):1400-8. PubMed ID: 10945534 [TBL] [Abstract][Full Text] [Related]
33. [Clinical utility of attenuation correction with X-rays in myocardial perfusion SPECT studies]. Bajén MT; Ricart Y; Rodríguez-Gasén A; Mora J; Quintana ME; Benítez A; Domènech A; Ruiz-Mayoral A; Puchal R; Pallarés C; Martín-Comín J Rev Esp Med Nucl; 2007; 26(6):359-66. PubMed ID: 18021690 [TBL] [Abstract][Full Text] [Related]
34. Attenuation correction in cardiac SPECT without a transmission measurement. Wallis JW; Miller TR; Koppel P J Nucl Med; 1995 Mar; 36(3):506-12. PubMed ID: 7884518 [TBL] [Abstract][Full Text] [Related]
35. [Correction measured by attenuation in tomographic heart studies with single photon emission with thallium 201. Comparison with positron- emission tomographic studies with ammonium marked with nitrogen]. Savi A; Rossetti C; Gilardi MC; Landoni C; Rizzo G; Ippolito M; Garraffa G; Lucignani G Radiol Med; 1999; 98(1-2):36-42. PubMed ID: 10566294 [TBL] [Abstract][Full Text] [Related]
37. Effect of scatter and attenuation correction in ROI analysis of brain perfusion scintigraphy: phantom experiment and clinical study in patients with unilateral cerebrovascular disease. Bai J; Hashimoto J; Ogawa K; Kubo A; Fukunaga A; Onozuka S Nuklearmedizin; 2007; 46(3):101-6. PubMed ID: 17549321 [TBL] [Abstract][Full Text] [Related]
38. Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease. Maddahi J; Kiat H; Van Train KF; Prigent F; Friedman J; Garcia EV; Alazraki N; DePuey EG; Nichols K; Berman DS Am J Cardiol; 1990 Oct; 66(13):55E-62E. PubMed ID: 2145748 [TBL] [Abstract][Full Text] [Related]
39. Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for (201)Tl studies. Harel F; Génin R; Daou D; Lebtahi R; Delahaye N; Helal BO; Le Guludec D; Faraggi M J Nucl Med; 2001 Oct; 42(10):1451-6. PubMed ID: 11585856 [TBL] [Abstract][Full Text] [Related]