These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 10358989)

  • 1. Mesh-and-glue technique to prevent leakage of cerebrospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute--technical note.
    Nagata K; Kawamoto S; Sashida J; Abe T; Mukasa A; Imaizumi Y
    Neurol Med Chir (Tokyo); 1999 Apr; 39(4):316-8; discussion 318-9. PubMed ID: 10358989
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.
    Ito K; Aoyama T; Horiuchi T; Hongo K
    J Neurosurg Spine; 2015 Dec; 23(6):812-9. PubMed ID: 26315957
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Mesh and glue technique as a new sealing technique for the use of expanded polytetrafluoroethylene dura substitute: the experimental studies of its tolerance for pressure and long-term histological changes].
    Nagata K; Shiobara Y; Kobayashi H; Shiba T; Yanagisawa A; Maruyama S
    No Shinkei Geka; 1999 Dec; 27(12):1097-103. PubMed ID: 10629890
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dural substitute with polyglycolic acid mesh and fibrin glue for dural repair: technical note and preliminary results.
    Shimada Y; Hongo M; Miyakoshi N; Sugawara T; Kasukawa Y; Ando S; Ishikawa Y; Itoi E
    J Orthop Sci; 2006 Oct; 11(5):454-8. PubMed ID: 17013732
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes.
    Nakajima S; Fukuda T; Hasue M; Sengoku Y; Haraoka J; Uchida T
    Neurosurgery; 2001 Jul; 49(1):117-23. PubMed ID: 11440432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: clinical application to spinal surgery.
    Hida K; Yamaguchi S; Seki T; Yano S; Akino M; Terasaka S; Uchida T; Iwasaki Y
    Surg Neurol; 2006 Feb; 65(2):136-42; discussion 142-3. PubMed ID: 16427404
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Direct suture technique of normal gland edge on the incised dura margin to repair the intraoperative cerebrospinal fluid leakage from the arachnoid recess during transsphenoidal pituitary tumor surgery.
    Kim EH; Roh TH; Park HH; Moon JH; Hong JB; Kim SH
    Neurosurgery; 2015 Mar; 11 Suppl 2():26-31; discussion 31. PubMed ID: 25584954
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Risk factors for postoperative CSF leakage after elective craniotomy and the efficacy of fleece-bound tissue sealing against dural suturing alone: a randomized controlled trial.
    Hutter G; von Felten S; Sailer MH; Schulz M; Mariani L
    J Neurosurg; 2014 Sep; 121(3):735-44. PubMed ID: 25036199
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial.
    Terasaka S; Taoka T; Kuroda S; Mikuni N; Nishi T; Nakase H; Fujii Y; Hayashi Y; Murata JI; Kikuta KI; Kuroiwa T; Shimokawa S; Houkin K
    J Mater Sci Mater Med; 2017 May; 28(5):69. PubMed ID: 28357687
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Sealing effect of fibrin glue spray on protection of cerebrospinal fluid leakage through the dura mata].
    Terasaka S; Sawamura Y; Abe H
    No Shinkei Geka; 1994 Nov; 22(11):1015-9. PubMed ID: 7816169
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New technique for decompressive duraplasty using expanded polytetrafluoroethylene dura substitute--technical note.
    Miyake S; Fujita A; Aihara H; Kohmura E
    Neurol Med Chir (Tokyo); 2006 Feb; 46(2):104-6; discussion 106. PubMed ID: 16498223
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Novel dural closure technique using polyglactin acid sheet prevents cerebrospinal fluid leakage after spinal surgery.
    Sugawara T; Itoh Y; Hirano Y; Higashiyama N; Shimada Y; Kinouchi H; Mizoi K
    Neurosurgery; 2005 Oct; 57(4 Suppl):290-4; discussion 290-4. PubMed ID: 16234677
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial.
    Nakamura H; Matsuyama Y; Yoshihara H; Sakai Y; Katayama Y; Nakashima S; Takamatsu J; Ishiguro N
    Spine (Phila Pa 1976); 2005 Jul; 30(13):E347-51. PubMed ID: 15990651
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Subdural patch graft technique for watertight closure of large dural defects in extended transsphenoidal surgery.
    Kitano M; Taneda M
    Neurosurgery; 2004 Mar; 54(3):653-60; discussion 660-1. PubMed ID: 15028140
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Duraplasty using autologous fascia lata reenforced by on-site pedicled muscle flap: technical note.
    Abuzayed B; Kafadar AM; Oğuzoğlu SA; Canbaz B; Kaynar MY
    J Craniofac Surg; 2009 Mar; 20(2):435-8. PubMed ID: 19326487
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Biocompatibility of ePTFE modified by ion beam irradiation].
    Takahashi N; Ujiie H; Suzuki Y; Iwaki M; Hori T
    No Shinkei Geka; 2004 Apr; 32(4):339-44. PubMed ID: 15227840
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Natura abhorret a vacuo--use of fibrin glue as a filler and sealant in neurosurgical "dead spaces". Technical note.
    Cappabianca P; Esposito F; Magro F; Cavallo LM; Solari D; Stella L; de Divitiis O
    Acta Neurochir (Wien); 2010 May; 152(5):897-904. PubMed ID: 20049488
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The dural repair using the combination of polyglycolic acid mesh and fibrin glue and postoperative management in spine surgery.
    Masuda S; Fujibayashi S; Otsuki B; Kimura H; Neo M; Matsuda S
    J Orthop Sci; 2016 Sep; 21(5):586-90. PubMed ID: 27519623
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new technique of dural closure--experience with a vicryl mesh.
    Verheggen R; Schulte-Baumann WJ; Hahm G; Lang J; Freudenthaler S; Schaake T; Markakis E
    Acta Neurochir (Wien); 1997; 139(11):1074-9. PubMed ID: 9442223
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effectiveness of fibrin glue for preventing postoperative extradural fluid leakage.
    Yoshimoto T; Sawamura Y; Houkin K; Abe H
    Neurol Med Chir (Tokyo); 1997 Dec; 37(12):886-9; discussion 889-90. PubMed ID: 9465586
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.