These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 10376065)

  • 1. In vivo evaluation of the adjustable temporary venous spring filter and the RF02 temporary filter: comparative study.
    Hosaka J; Roy S; Kvernebo K; Enge I; Laerum F
    Acad Radiol; 1999 Jun; 6(6):343-51. PubMed ID: 10376065
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro function of an adjustable temporary venous spring filter: comparison with the temporary RF02 filter and the permanent Greenfield vena cava filter.
    Hosaka J; Roy S; Kvernebo K; Enge I; Laerum F
    Acad Radiol; 1998 Sep; 5(9):620-5. PubMed ID: 9750891
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adjustable temporary venous spring filter: in vitro assessment.
    Hosaka J; Roy S; Kvernebo K; Enge I; Laerum F
    Acad Radiol; 1997 Jul; 4(7):513-8. PubMed ID: 9232172
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Role of prophylactic temporary inferior vena cava filters placed at the ICU bedside under intravascular ultrasound guidance in patients with multiple trauma.
    Rosenthal D; Wellons ED; Levitt AB; Shuler FW; O'Conner RE; Henderson VJ
    J Vasc Surg; 2004 Nov; 40(5):958-64. PubMed ID: 15557911
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Temporary inferior vena cava filters: in vitro comparison with permanent IVC filters.
    Stoneham GW; Burbridge BE; Millward SF
    J Vasc Interv Radiol; 1995; 6(5):731-6. PubMed ID: 8541676
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a spiral nitinol temporary inferior vena caval filter.
    Stecker MS; Barnhart WH; Lang EV
    Acad Radiol; 2001 Jun; 8(6):484-93. PubMed ID: 11394541
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New optional IVC filter for percutaneous retrieval--in vitro evaluation of embolus capturing efficiency.
    Günther RW; Neuerburg J; Mossdorf A; Pfeffer J; Høj AR; Mølgaard-Nielsen A; Bücker A; Schmitz-Rode T
    Rofo; 2005 May; 177(5):632-6. PubMed ID: 15871077
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro evaluation of a new temporary venous filter: the Spring filter.
    Xian ZY; Roy S; Hosaka J; Kuroki K; Kvernebo K; Enge I; Laerum F
    Cardiovasc Intervent Radiol; 1995; 18(5):315-20. PubMed ID: 8846472
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro evaluation of clot capture efficiency of an absorbable vena cava filter.
    Dria SJ; Eggers MD
    J Vasc Surg Venous Lymphat Disord; 2016 Oct; 4(4):472-8. PubMed ID: 27639002
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multiple emboli and filter function: an in vitro comparison of three vena cava filters.
    Xian ZY; Roy S; Hosaka J; Kvernebo K; Laerum F
    J Vasc Interv Radiol; 1995; 6(6):887-93. PubMed ID: 8850665
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro and in vivo experimental evaluation of a new vena caval filter.
    Qian Z; Yasui K; Nazarian GK; Vlodaver Z; Hunter DW; Castaneda-Zuniga WR; Amplatz K
    J Vasc Interv Radiol; 1994; 5(3):513-8. PubMed ID: 8054757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical thrombolysis of venous thrombosis in an animal model with use of temporary caval filtration.
    Trerotola SO; McLennan G; Eclavea AC; Salis A; Davidson D; Dreesen RG; Tennery J
    J Vasc Interv Radiol; 2001 Sep; 12(9):1075-85. PubMed ID: 11535771
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of a TrapEase device as a temporary caval filter.
    Nutting C; Coldwell D
    J Vasc Interv Radiol; 2001 Aug; 12(8):991-3. PubMed ID: 11487681
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Double-filter technique for deployment of a permanent inferior vena cava filter while avoiding the risk of pulmonary embolism from a thrombus trapped by a temporary filter.
    Nomura T; Komatsu S; Arihara M; Hayashi H; Syudo T; Harada Y; Hosomi Y; Hirano S; Matsubara H
    Heart Vessels; 2007 May; 22(3):199-201. PubMed ID: 17533525
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early technical and clinical results with retrievable inferior vena caval filters.
    Lam RC; Bush RL; Lin PH; Lumsden AB
    Vascular; 2004; 12(4):233-7. PubMed ID: 15704317
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A retrievable nitinol vena cava filter: experimental and initial clinical results.
    Nakagawa N; Cragg AH; Smith TP; Castaneda F; Barnhart WH; DeJong SC
    J Vasc Interv Radiol; 1994; 5(3):507-12. PubMed ID: 8054756
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pilot in vivo study of an absorbable polydioxanone vena cava filter.
    Eggers MD; McArthur MJ; Figueira TA; Abdelsalam ME; Dixon KP; Pageon LR; Wallace MJ; Huang SY
    J Vasc Surg Venous Lymphat Disord; 2015 Oct; 3(4):409-420. PubMed ID: 26992619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acute clot-trapping efficiency in dogs with compacted versus elongated wires in bird's nest filters.
    Carlson JE; Yedlicka JW; Castaneda-Zuniga WR; Hunter DW; Amplatz K
    J Vasc Interv Radiol; 1993; 4(4):513-6. PubMed ID: 8353348
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Placement of a spring filter during interventional treatment of deep venous thrombosis to reduce the risk of pulmonary embolism.
    Hosaka J; Roy S; Kuroki K; Xian Z; Kvernebo K; Enge I; Laerum F
    Acta Radiol; 1999 Sep; 40(5):545-51. PubMed ID: 10485246
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Numerical analysis of the hemodynamics and embolus capture of a greenfield vena cava filter.
    Swaminathan TN; Hu HH; Patel AA
    J Biomech Eng; 2006 Jun; 128(3):360-70. PubMed ID: 16706585
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.