  • 1. Nonsurgical transvenous retrieval of fractured implantable central venous access device.
    Huang CH; Chen WJ; Ho YL; Wu CC; Lee YT
    J Formos Med Assoc; 1999 Apr; 98(4):265-70. PubMed ID: 10389371
    [TBL] [Abstract][Full Text] [Related]  

  • 2. ["Pinch-off sign" and spontaneous fracture of an implanted central venous catheter: report of a case].
    Hou WY; Sun WZ; Chen YA; Wu SM; Lin SY
    J Formos Med Assoc; 1994 Mar; 93 Suppl 1():S65-9. PubMed ID: 7920098
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Pinch-off syndrome].
    Staniscia G; Perenze B; De Nicola E; Potì O
    Ann Ital Chir; 2008; 79(6):463-5. PubMed ID: 19354044
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Catheter fracture: a rare complication of totally implantable subclavian venous access devices.
    Klotz HP; Schöpke W; Kohler A; Pestalozzi B; Largiadèr F
    J Surg Oncol; 1996 Jul; 62(3):222-5. PubMed ID: 8667632
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Catheter fracture and embolization: a rare complication of a permanent implanted intravenous catheter system].
    Mazel JW; Idenburg FJ; van Delden OM
    Ned Tijdschr Geneeskd; 2000 Jul; 144(28):1360-3. PubMed ID: 10923159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients.
    Bessoud B; de Baere T; Kuoch V; Desruennes E; Cosset MF; Lassau N; Roche A
    AJR Am J Roentgenol; 2003 Feb; 180(2):527-32. PubMed ID: 12540466
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pinch-off syndrome: case report and collective review of the literature.
    Mirza B; Vanek VW; Kupensky DT
    Am Surg; 2004 Jul; 70(7):635-44. PubMed ID: 15279190
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Catheter embolization from implanted venous access devices: case reports.
    Carr ME
    Angiology; 1989 Apr; 40(4 Pt 1):319-23. PubMed ID: 2705640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Pinch-off syndrome and rupture of totally implanted venous access. Report of a case].
    Ferrari A; Nahas S; Maccaferri R; Malacarne P
    Recenti Prog Med; 2000 Jun; 91(6):297-300. PubMed ID: 11512387
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pinch-off syndrome: a complication of implantable subclavian venous access devices.
    Hinke DH; Zandt-Stastny DA; Goodman LR; Quebbeman EJ; Krzywda EA; Andris DA
    Radiology; 1990 Nov; 177(2):353-6. PubMed ID: 2217768
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Pinch-off syndrome. Case report and review of the literature].
    Morales-Victorino N; Damas de los Santos F; Kuri-Ayache M; López-Aguilar C
    Gac Med Mex; 2015; 151(4):529-32. PubMed ID: 26290031
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Catheter fracture and cardiac migration--an unusual fracture site of totally implantable venous devices: report of two cases.
    Chang CL; Chen HH; Lin SE
    Chang Gung Med J; 2005 Jun; 28(6):425-30. PubMed ID: 16124159
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Case report: the malfunctioning implanted venous access device.
    Schummer W; Schummer C; Schelenz C
    Br J Nurs; 2003 Feb 27-Mar 12; 12(4):210, 212-4. PubMed ID: 12671566
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pinch-off syndrome: transection of implantable central venous access device.
    Sugimoto T; Nagata H; Hayashi K; Kano N
    BMJ Case Rep; 2012 Nov; 2012():. PubMed ID: 23203173
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port].
    Rebahi H; El Adib AG; Mouaffak Y; El Hattaoui M; Chaara A; Sadek H; Khouchani M; Mahmal L; Younous S
    Rev Med Interne; 2015 Jan; 36(1):42-6. PubMed ID: 24050786
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Retained Fractured Fragment of A Central Venous Catheter: A Minimally Invasive Approach to Safe Retrieval.
    Hamad M; Rajan R; Kosai N; Sutton P; Das S; Harunarashid H
    Ethiop J Health Sci; 2016 Jan; 26(1):85-8. PubMed ID: 26949321
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Chest pain due to Pinch-off syndrome: radiological findings and endovascular rescue.
    Viviani E; Giribono AM; Ferrara D; Santagata A; Narese D; Midiri F; Albano D; Porcellini M
    Clin Ter; 2016; 167(1):13-5. PubMed ID: 26980633
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Successful percutaneous transvenous retrieval of intravascular fractured port catheter: a single center experience.
    Li Y; Chen J; Li Z; Lu H; Ren K; Ren J; Han X
    J Cardiothorac Surg; 2020 May; 15(1):101. PubMed ID: 32423421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The mechanisms of failure of totally implantable central venous access system: analysis of 73 cases with fracture of catheter.
    Lin CH; Wu HS; Chan DC; Hsieh CB; Huang MH; Yu JC
    Eur J Surg Oncol; 2010 Jan; 36(1):100-3. PubMed ID: 19709847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Complications and management of percutaneous central venous access catheter].
    Hou WY; Suseceto L; Lin SY; Sun WZ
    J Formos Med Assoc; 1994 Sep; 93 Suppl 2():S109-14. PubMed ID: 7719163
    [TBL] [Abstract][Full Text] [Related]  