BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 10392496)

  • 1. Adjustable antisiphon shunt.
    Sood S; Canady AI; Ham SD
    Childs Nerv Syst; 1999 May; 15(5):246-9. PubMed ID: 10392496
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The delta valve: how does its clinical performance compare with two other pressure differential valves without antisiphon control?
    Davis SE; Levy ML; McComb JG; Sposto R
    Pediatr Neurosurg; 2000 Aug; 33(2):58-63. PubMed ID: 11070430
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Addressing the siphoning effect in new shunt designs by decoupling the activation pressure and the pressure gradient across the valve.
    Mattei TA; Morris M; Nowak K; Smith D; Yee J; Goulart CR; Zborowski A; Lin JJ
    J Neurosurg Pediatr; 2013 Feb; 11(2):181-7. PubMed ID: 23215676
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ventriculoperitoneal Shunt Drainage Increases With Gravity and Cerebrospinal Fluid Pressure Pulsations: Benchtop Model.
    Koueik J; Iskandar BJ; Yang Z; Kraemer MR; Armstrong S; Wakim V; Broman AT; Medow J; Luzzio C; Hsu DA
    Neurosurgery; 2021 Nov; 89(6):1141-1147. PubMed ID: 34528096
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Laboratory testing of hydrocephalus shunts -- conclusion of the U.K. Shunt evaluation programme.
    Czosnyka Z; Czosnyka M; Richards HK; Pickard JD
    Acta Neurochir (Wien); 2002 Jun; 144(6):525-38; discussion 538. PubMed ID: 12111485
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro performance of the fixed and adjustable gravity-assisted unit with and without motion-evidence of motion-induced flow.
    Kimura T; Schulz M; Shimoji K; Miyajima M; Arai H; Thomale UW
    Acta Neurochir (Wien); 2016 Oct; 158(10):2011-8. PubMed ID: 27553048
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The treatment of infantile hydrocephalus: "differential-pressure" or "flow-control" valves. A pilot study.
    Jain H; Sgouros S; Walsh AR; Hockley AD
    Childs Nerv Syst; 2000 Apr; 16(4):242-6. PubMed ID: 10855523
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Revision to an adjustable non-siphon control valve in low pressure hydrocephalus: therapeutic siphoning and a new perspective on NPH: series of 3 cases and review of the literature.
    Trinh VT; Duckworth EA
    Clin Neurol Neurosurg; 2013 Feb; 115(2):175-8. PubMed ID: 22770726
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Posture-independent piston valve: a novel valve mechanism that actuates based on intracranial pressure alone.
    Medow JE; Luzzio CC
    J Neurosurg Pediatr; 2012 Jan; 9(1):64-8. PubMed ID: 22208323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The programmable adult Codman Hakim valve is useful even in very small children with hydrocephalus. A 7-year retrospective study with special focus on cost/benefit analysis.
    Arnell K; Eriksson E; Olsen L
    Eur J Pediatr Surg; 2006 Feb; 16(1):1-7. PubMed ID: 16544218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of antisiphon devices on ventriculoperitoneal shunt drainage dynamics in growing children.
    Tachatos N; Fernandes Dias S; Jehli E; Lübben D; Schuhmann MU; Schmid Daners M
    J Neurosurg Pediatr; 2023 Jul; 32(1):50-59. PubMed ID: 37119102
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rationale and methodology of the multicenter pediatric cerebrospinal fluid shunt design trial. Pediatric Hydrocephalus Treatment Evaluation Group.
    Drake JM; Kestle J
    Childs Nerv Syst; 1996 Aug; 12(8):434-47. PubMed ID: 8891361
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Shunt survival rates by using the adjustable differential pressure valve combined with a gravitational unit (proGAV) in pediatric neurosurgery.
    Thomale UW; Gebert AF; Haberl H; Schulz M
    Childs Nerv Syst; 2013 Mar; 29(3):425-31. PubMed ID: 23135777
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of fixed-pressure valve with antisiphon device SPHERA(®) in hydrocephalus treatment and overdrainage prevention.
    Pinto FC; Pereira RM; Saad F; Teixeira MJ
    Arq Neuropsiquiatr; 2012 Sep; 70(9):704-9. PubMed ID: 22990728
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of anti-siphon devices-how do they affect CSF dynamics in supine and upright posture?
    Gehlen M; Eklund A; Kurtcuoglu V; Malm J; Schmid Daners M
    Acta Neurochir (Wien); 2017 Aug; 159(8):1389-1397. PubMed ID: 28660395
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus.
    Drake JM; Kestle JR; Milner R; Cinalli G; Boop F; Piatt J; Haines S; Schiff SJ; Cochrane DD; Steinbok P; MacNeil N
    Neurosurgery; 1998 Aug; 43(2):294-303; discussion 303-5. PubMed ID: 9696082
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of alignment on the pressure/flow characteristics of flow control shunt valves.
    Francel PC; Honeycutt J; Tompkins P
    Childs Nerv Syst; 2001 Aug; 17(8):467-70; discussion 471. PubMed ID: 11508535
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Treatment of refractory low-pressure hydrocephalus with an active pumping negative-pressure shunt system.
    Kalani MY; Turner JD; Nakaji P
    J Clin Neurosci; 2013 Mar; 20(3):462-6. PubMed ID: 23380444
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Posture-related overdrainage: comparison of the performance of 10 hydrocephalus shunts in vitro.
    Czosnyka Z; Czosnyka M; Richards HK; Pickard JD
    Neurosurgery; 1998 Feb; 42(2):327-33; discussion 333-4. PubMed ID: 9482183
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An adjustable CSF shunt: advices for clinical use.
    Lundkvist B; Eklund A; Koskinen LO; Malm J
    Acta Neurol Scand; 2003 Jul; 108(1):38-42. PubMed ID: 12807391
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.