  • 1. [Loading on internal spinal fixation devices].
    Rohlmann A; Bergmann G; Graichen F; Weber U
    Orthopade; 1999 May; 28(5):451-7. PubMed ID: 10394604
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Loads on internal spinal fixation devices.
    Rohlmann A; Bergmann G; Graichen F; Weber U
    Orthopade; 1999 May; 28(5):451-457. PubMed ID: 28246960
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Braces do not reduce loads on internal spinal fixation devices.
    Rohlmann A; Bergmann G; Graichen F; Neff G
    Clin Biomech (Bristol); 1999 Feb; 14(2):97-102. PubMed ID: 10619096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Loads on a telemeterized vertebral body replacement measured in two patients.
    Rohlmann A; Graichen F; Kayser R; Bender A; Bergmann G
    Spine (Phila Pa 1976); 2008 May; 33(11):1170-9. PubMed ID: 18469689
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Stress measurements with an instrumented internal spinal fixator].
    Rohlmann A; Eick O; Bergmann G; Graichen F
    Biomed Tech (Berl); 1993 Oct; 38(10):255-9. PubMed ID: 8268404
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month.
    Rohlmann A; Graichen F; Bender A; Kayser R; Bergmann G
    Clin Biomech (Bristol); 2008 Feb; 23(2):147-58. PubMed ID: 17983694
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability.
    Rohlmann A; Bergmann G; Graichen F; Mayer HM
    Spine (Phila Pa 1976); 1995 Dec; 20(24):2683-9. PubMed ID: 8747246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro fixator rod loading after transforaminal compared to anterior lumbar interbody fusion.
    Kettler A; Niemeyer T; Issler L; Merk U; Mahalingam M; Werner K; Claes L; Wilke HJ
    Clin Biomech (Bristol); 2006 Jun; 21(5):435-42. PubMed ID: 16442678
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients.
    Oertel J; Niendorf WR; Darwish N; Schroeder HW; Gaab MR
    Acta Neurochir (Wien); 2004 Aug; 146(8):771-7. PubMed ID: 15254799
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 2000 Volvo Award winner in biomechanical studies: Monitoring in vivo implant loads with a telemeterized internal spinal fixation device.
    Rohlmann A; Graichen F; Weber U; Bergmann G
    Spine (Phila Pa 1976); 2000 Dec; 25(23):2981-6. PubMed ID: 11145808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [In-vitro measurement of loading using an instrumented vertebral internal fixator].
    Rohlmann A; Eick O; Bergmann G; Graichen F
    Z Orthop Ihre Grenzgeb; 1995; 133(2):136-40. PubMed ID: 7754660
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column.
    Rohlmann A; Gabel U; Graichen F; Bender A; Bergmann G
    Med Eng Phys; 2007 Jun; 29(5):580-5. PubMed ID: 16931099
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Loads on internal spinal fixators measured in different body positions.
    Rohlmann A; Bergmann G; Graichen F
    Eur Spine J; 1999; 8(5):354-9. PubMed ID: 10552317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Loads on an internal spinal fixation device during physical therapy.
    Rohlmann A; Graichen F; Bergmann G
    Phys Ther; 2002 Jan; 82(1):44-52. PubMed ID: 11784277
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Treatment of thoracolumbar spinal fractures using internal fixators (evaluation of 120 cases)].
    Krbec M; StulĂ­k J
    Acta Chir Orthop Traumatol Cech; 2001; 68(2):77-84. PubMed ID: 11706721
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model.
    Gerber M; Crawford NR; Chamberlain RH; Fifield MS; LeHuec JC; Dickman CA
    Spine (Phila Pa 1976); 2006 Apr; 31(7):762-8. PubMed ID: 16582849
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises.
    Rohlmannt A; Claes LE; Bergmannt G; Graichen F; Neef P; Wilke HJ
    Ergonomics; 2001 Jun; 44(8):781-94. PubMed ID: 11450876
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Clinical features and strategies for treatment of spinal fracture complicating ankylosing spondylitis].
    Qian BP; Qiu Y; Wang B; Yu Y; Zhu ZZ
    Zhonghua Yi Xue Za Zhi; 2007 Nov; 87(41):2893-8. PubMed ID: 18261302
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measured loads on a vertebral body replacement during sitting.
    Rohlmann A; Zander T; Graichen F; Dreischarf M; Bergmann G
    Spine J; 2011 Sep; 11(9):870-5. PubMed ID: 21775218
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Loads on an internal spinal fixation device during walking.
    Rohlmann A; Bergmann G; Graichen F
    J Biomech; 1997 Jan; 30(1):41-7. PubMed ID: 8970923
    [TBL] [Abstract][Full Text] [Related]  