110 related articles for article (PubMed ID: 10398043)
1. Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: effect of starting resin and forming method.
James SP; Lee KR; Beauregard GP; Rentfrow ED; McLaughlin JR
J Biomed Mater Res; 1999; 48(3):374-84. PubMed ID: 10398043
[TBL] [Abstract][Full Text] [Related]
2. Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
Rentfrow ED; James SP; Beauregard GP; Lee KR; McLaughlin JR
Biomed Sci Instrum; 1996; 32():135-41. PubMed ID: 8672661
[TBL] [Abstract][Full Text] [Related]
3. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.
Benson LC; DesJardins JD; LaBerge M
J Biomed Mater Res; 2001; 58(5):496-504. PubMed ID: 11505423
[TBL] [Abstract][Full Text] [Related]
4. Comparison of polyethylene wear in machined versus molded polyethylene.
Bankston AB; Keating EM; Ranawat C; Faris PM; Ritter MA
Clin Orthop Relat Res; 1995 Aug; (317):37-43. PubMed ID: 7671494
[TBL] [Abstract][Full Text] [Related]
5. Acetabular UHMWPE survival and wear changes with different manufacturing techniques.
Meding JB; Keating EM; Davis KE
Clin Orthop Relat Res; 2011 Feb; 469(2):405-11. PubMed ID: 20852973
[TBL] [Abstract][Full Text] [Related]
6. Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements.
Berzins A; Jacobs JJ; Berger R; Ed C; Natarajan R; Andriacchi T; Galante JO
J Bone Joint Surg Am; 2002 Sep; 84(9):1534-40. PubMed ID: 12208909
[TBL] [Abstract][Full Text] [Related]
7. [Radiographic assessment of polyethylene wear in machined versus molded polyethylene in total hip prosthesis].
Courpied J; Delhoume J; Kerboull L; Kerboull M
Rev Chir Orthop Reparatrice Appar Mot; 2000 Feb; 86(1):10-4. PubMed ID: 10669819
[TBL] [Abstract][Full Text] [Related]
8. Polyethylene wear in total hip arthroplasty.
Bankston AB; Cates H; Ritter MA; Keating EM; Faris PM
Clin Orthop Relat Res; 1995 Aug; (317):7-13. PubMed ID: 7671498
[TBL] [Abstract][Full Text] [Related]
9. Wear testing of materials and surfaces for total knee replacement.
Walker PS; Blunn GW; Lilley PA
J Biomed Mater Res; 1996; 33(3):159-75. PubMed ID: 8864888
[TBL] [Abstract][Full Text] [Related]
10. Implant wear mechanisms--basic approach.
Bhatt H; Goswami T
Biomed Mater; 2008 Dec; 3(4):042001. PubMed ID: 18824778
[TBL] [Abstract][Full Text] [Related]
11. Delamination and adhesive wear behavior of alpha-tocopherol-stabilized irradiated ultrahigh-molecular-weight polyethylene.
Wannomae KK; Christensen SD; Micheli BR; Rowell SL; Schroeder DW; Muratoglu OK
J Arthroplasty; 2010 Jun; 25(4):635-43. PubMed ID: 19493652
[TBL] [Abstract][Full Text] [Related]
12. Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement. Ultra-high-molecular-weight polyethylene.
Edidin AA; Pruitt L; Jewett CW; Crane DJ; Roberts D; Kurtz SM
J Arthroplasty; 1999 Aug; 14(5):616-27. PubMed ID: 10475563
[TBL] [Abstract][Full Text] [Related]
13. The influence of irradiation dose on mechanical properties and wear resistance of molded and extruded ultra high molecular weight polyethylene.
Xiong L; Xiong D
J Mech Behav Biomed Mater; 2012 May; 9():73-82. PubMed ID: 22498285
[TBL] [Abstract][Full Text] [Related]
14. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.
Korduba LA; Essner A; Pivec R; Lancin P; Mont MA; Wang A; Delanois RE
Am J Orthop (Belle Mead NJ); 2014 Oct; 43(10):466-71. PubMed ID: 25303445
[TBL] [Abstract][Full Text] [Related]
15. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations.
Jasty M; Goetz DD; Bragdon CR; Lee KR; Hanson AE; Elder JR; Harris WH
J Bone Joint Surg Am; 1997 Mar; 79(3):349-58. PubMed ID: 9070522
[TBL] [Abstract][Full Text] [Related]
16. Polyethylene sterilization and production affects wear in total hip arthroplasties.
Faris PM; Ritter MA; Pierce AL; Davis KE; Faris GW
Clin Orthop Relat Res; 2006 Dec; 453():305-8. PubMed ID: 16906113
[TBL] [Abstract][Full Text] [Related]
17. Radiographic measurement of wear in 5 cohorts of patients observed for 5 to 22 years.
Callaghan JJ; Pedersen DR; Olejniczak JP; Goetz DD; Johnston RC
Clin Orthop Relat Res; 1995 Aug; (317):14-8. PubMed ID: 7671468
[TBL] [Abstract][Full Text] [Related]
18. [Analysis of Oxidative Damage to Components Removed from Beznoska/Poldi Total Hip Replacements].
Fulín P; Pokorný D; Šlouf M; Nevoralová M; Vacková T; Dybal J; Kaspříková N; Landor I
Acta Chir Orthop Traumatol Cech; 2016; 83(3):155-62. PubMed ID: 27484072
[TBL] [Abstract][Full Text] [Related]
19. Wear data and clinical results for a compression molded monoblock elliptical acetabular component: 5- to 9-year data.
Mayman DJ; Anderson JA; Su EP; Sculco TP
J Arthroplasty; 2007 Sep; 22(6 Suppl 2):130-3. PubMed ID: 17823031
[TBL] [Abstract][Full Text] [Related]
20. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients: a prospective randomised controlled trial.
Atrey A; Ward SE; Khoshbin A; Hussain N; Bogoch E; Schemitsch EH; Waddell JP
Bone Joint J; 2017 Dec; 99-B(12):1590-1595. PubMed ID: 29212681
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]