These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
140 related articles for article (PubMed ID: 10404383)
1. Bilateral microcornea and unilateral macrophthalmia resulting in incorrect intraocular lens selection. Brannan SO; Kyle G J Cataract Refract Surg; 1999 Jul; 25(7):1016-8. PubMed ID: 10404383 [TBL] [Abstract][Full Text] [Related]
2. Posterior chamber intraocular lens implantation in pediatric cataract with microcornea and/or microphthalmos. Yu YS; Kim SJ; Choung HK Korean J Ophthalmol; 2006 Sep; 20(3):151-5. PubMed ID: 17004628 [TBL] [Abstract][Full Text] [Related]
3. Intraocular lens exchange due to incorrect lens power. Jin GJ; Crandall AS; Jones JJ Ophthalmology; 2007 Mar; 114(3):417-24. PubMed ID: 17123608 [TBL] [Abstract][Full Text] [Related]
4. Intraocular lens power calculation for microphthalmos. Inatomi M; Ishii K; Koide R; Kora Y; Ozawa T J Cataract Refract Surg; 1997 Oct; 23(8):1208-12. PubMed ID: 9368166 [TBL] [Abstract][Full Text] [Related]
5. Significant postoperative refractive errors in vivo with the Mentor Memorylens intraocular lens. Nelson TD; Zabriskie NA; Brodstein DE; Baker MR; Alder SC; Richards BW J Cataract Refract Surg; 2002 Apr; 28(4):656-61. PubMed ID: 11955907 [TBL] [Abstract][Full Text] [Related]
6. [The analysis of refractive error of long axial high myopic eyes after IOL implantation]. Zheng Q; Zhao Z; Lian H; Zhao Y Zhonghua Yan Ke Za Zhi; 2015 Apr; 51(4):276-81. PubMed ID: 26081231 [TBL] [Abstract][Full Text] [Related]
7. Intraocular lens power calculation for lens exchange. Kora Y; Shimizu K; Yoshida M; Inatomi M; Ozawa T J Cataract Refract Surg; 2001 Apr; 27(4):543-8. PubMed ID: 11311621 [TBL] [Abstract][Full Text] [Related]
9. Comparison of intraocular lens power calculation by the IOLMaster in phakic and eyes with hydrophobic acrylic lenses. Chang SW; Yu CY; Chen DP Ophthalmology; 2009 Jul; 116(7):1336-42. PubMed ID: 19427697 [TBL] [Abstract][Full Text] [Related]
10. Refractive and visual outcome of hyperopic cataract cases operated on before and after implementation of the Holladay II formula. Fenzl RE; Gills JP; Cherchio M Ophthalmology; 1998 Sep; 105(9):1759-64. PubMed ID: 9754188 [TBL] [Abstract][Full Text] [Related]
12. Influence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgery. Choi Y; Eom Y; Song JS; Kim HM BMC Ophthalmol; 2017 Dec; 17(1):261. PubMed ID: 29282016 [TBL] [Abstract][Full Text] [Related]
13. [Intraocular lens power calculation for high myopic eyes with cataract: comparison of three formulas]. Zhu XJ; He WW; Du Y; Qian DJ; Dai JH; Lu Y Zhonghua Yan Ke Za Zhi; 2017 Apr; 53(4):260-265. PubMed ID: 28412798 [No Abstract] [Full Text] [Related]
14. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths. Karabela Y; Eliacik M; Kaya F BMC Ophthalmol; 2016 Jul; 16():96. PubMed ID: 27391470 [TBL] [Abstract][Full Text] [Related]
15. Pseudophakic ametropia managed with a phakic posterior chamber intraocular lens. Chiou AG; Bovet J; de Courten C J Cataract Refract Surg; 2001 Sep; 27(9):1516-8. PubMed ID: 11566542 [TBL] [Abstract][Full Text] [Related]
16. Refractive outcomes in nanophthalmic eyes after phacoemulsification and implantation of a high-refractive-power foldable intraocular lens. Singh H; Wang JC; Desjardins DC; Baig K; Gagné S; Ahmed II J Cataract Refract Surg; 2015 Nov; 41(11):2394-402. PubMed ID: 26703488 [TBL] [Abstract][Full Text] [Related]
17. Reliability of intraocular lens power calculation after cataract surgery in patients with relative anterior microphthalmos. Bartke TU; Auffarth GU; Uhl JC; Völcker HE Graefes Arch Clin Exp Ophthalmol; 2000 Feb; 238(2):138-42. PubMed ID: 10766282 [TBL] [Abstract][Full Text] [Related]