These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 10404771)

  • 61. European Concerted Action on Anticoagulation (ECAA). Minimum number of centres for reliable International Sensitivity Index calibration of CoaguChek and TAS point-of-care whole blood monitors.
    Poller L; Keown M; Chauhan N; van den Besselaar AM; Tripodi A; Shiach C; Jespersen J;
    Thromb Res; 2002 Jul; 107(1-2):61-6. PubMed ID: 12413591
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Local INR calibration of the Owren type prothrombin assay greatly improves the intra- and interlaboratory variation. A three-year follow-up from the Swedish national external quality assessment scheme.
    Hillarp A; Egberg N; Nordin G; Stigendal L; Fagerberg I; Lindahl TL
    Thromb Haemost; 2004 Feb; 91(2):300-7. PubMed ID: 14961158
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents.
    van den Besselaar AM; Hoekstra MM; Witteveen E; Didden JH; van der Meer FJ
    Am J Clin Pathol; 2007 May; 127(5):724-9. PubMed ID: 17439830
    [TBL] [Abstract][Full Text] [Related]  

  • 64. European Concerted Action on Anticoagulation. Evaluation of a method for International Sensitivity Index calibration of two point-of-care prothrombin time (PT) monitoring systems (CoaguChek Mini and TAS PT-NC) with fresh plasmas based on whole-blood equivalent PT.
    Poller L; Keown M; Chauhan N; van den Besselaar AM; Tripodi A; Shiach C; Jespersen J
    Clin Chem; 2002 Oct; 48(10):1672-80. PubMed ID: 12324483
    [TBL] [Abstract][Full Text] [Related]  

  • 65. System ISI calibration: a universally applicable scheme is possible only when coumarin plasma calibrants are used.
    Stevenson KJ; Craig S; Dufty JM; Taberner DA
    Br J Haematol; 1997 Mar; 96(3):435-41. PubMed ID: 9054644
    [TBL] [Abstract][Full Text] [Related]  

  • 66. European Concerted Action on Anticoagulation (ECAA): multicentre international sensitivity index calibration of two types of point-of-care prothrombin time monitor systems.
    Poller L; Keown M; Chauhan N; van Den Besselaar AM; Tripodi A; Jespersen J; Shiach C; Horellou MH; Dias D; Egberg N; Iriarte JA; Kontopoulou-Griva I; Otridge B
    Br J Haematol; 2002 Mar; 116(4):844-50. PubMed ID: 11886390
    [TBL] [Abstract][Full Text] [Related]  

  • 67. European concerted action on anticoagulation. Quality assessment of the CoaguChek Mini and TAS PT-NC point-of-care whole-blood prothrombin time monitors.
    Poller L; Keown M; Chauhan N; van den Besselaar AM; Tripodi A; Shiach C; Jespersen J
    Clin Chem; 2004 Mar; 50(3):537-44. PubMed ID: 14709449
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Effect of plasma pooling on the International Sensitivity Index of prothrombin time systems.
    van den Besselaar AM; Witteveen E; Schaefer-van Mansfeld H; van Rijn C; van der Meer FJ
    Blood Coagul Fibrinolysis; 1998 Oct; 9(7):645-51. PubMed ID: 9863714
    [TBL] [Abstract][Full Text] [Related]  

  • 69. A comparison of INRs determined with a whole blood prothrombin time device and two international reference preparations for thromboplastin.
    van den Besselaar AM
    Thromb Haemost; 2000 Sep; 84(3):410-2. PubMed ID: 11019963
    [TBL] [Abstract][Full Text] [Related]  

  • 70. The effect of sample size on fresh plasma thromboplastin ISI determination.
    Poller L; Van Den Besselaar AM; Jespersen J; Tripodi A; Houghton D
    Br J Haematol; 1999 Jun; 105(3):655-63. PubMed ID: 10354126
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Interaction of daptomycin with two recombinant thromboplastin reagents leads to falsely prolonged patient prothrombin time/International Normalized Ratio results.
    Webster PS; Oleson FB; Paterson DL; Arkin CF; Mangili A; Craven DE; Adcock DM; Lindfield KC; Knapp AG; Martone WJ
    Blood Coagul Fibrinolysis; 2008 Jan; 19(1):32-8. PubMed ID: 18180613
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Has the Quick or the Owren prothrombin time method the advantage in harmonization for the International Normalized Ratio system?
    Horsti J
    Blood Coagul Fibrinolysis; 2002 Oct; 13(7):641-6. PubMed ID: 12439151
    [TBL] [Abstract][Full Text] [Related]  

  • 73. [Determination of the international normalized ratio (INR)].
    Sousa SR
    Acta Med Port; 1998; 11(8-9):773-7. PubMed ID: 9951071
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Local INR correction: justification for a simplified approach.
    Craig S; Stevenson KJ; Dufty JM; Taberner DA
    J Clin Pathol; 1997 Sep; 50(9):783-9. PubMed ID: 9389982
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Local international normalised ratio (INR) derivation simplified using the European concerted action on anticoagulation (ECAA) prothrombin time/INR line.
    Poller L; Jespersen J
    Thromb Res; 2011 Aug; 128(2):101-2. PubMed ID: 21658749
    [No Abstract]   [Full Text] [Related]  

  • 76. International sensitivity index calibration of the near-patient testing prothrombin time monitor, ProTime.
    Tripodi A; Chantarangkul V; Bressi C; Mannucci PM
    Am J Clin Pathol; 2003 Feb; 119(2):241-5. PubMed ID: 12579994
    [TBL] [Abstract][Full Text] [Related]  

  • 77. International collaborative study for the calibration of a proposed international standard for thromboplastin, rabbit, plain.
    Chantarangkul V; van den Besselaar AM; Witteveen E; Tripodi A
    J Thromb Haemost; 2006 Jun; 4(6):1339-45. PubMed ID: 16706980
    [TBL] [Abstract][Full Text] [Related]  

  • 78. [Less variation in laboratory results after the introduction of INR. Differences between hospital laboratories and laboratories within primary health care are levelled out].
    Hillarp A; Egberg N; Fagerberg I; Lindahl TL; Nordin G; Stigendal L
    Lakartidningen; 2002 Dec; 99(50):5068-70, 5073-4. PubMed ID: 12572298
    [TBL] [Abstract][Full Text] [Related]  

  • 79. [Prothrombin time and its standardization].
    Kagawa K
    Rinsho Byori; 2002 Aug; 50(8):779-85. PubMed ID: 12373814
    [TBL] [Abstract][Full Text] [Related]  

  • 80. European concerted action on anticoagulation. Use of plasma samples to derive international sensitivity index for whole-blood prothrombin time monitors.
    Poller L; Keown M; Chauhan N; van den Besselaar AM; Meeuwisse-Braun J; Tripodi A; Clerici M; Jespersen J
    Clin Chem; 2002 Feb; 48(2):255-60. PubMed ID: 11805005
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.