These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 10408054)

  • 1. [Comparative static biomechanical studies of tripod surface structures of cementless endoprostheses].
    Mittelmeier W; Grunwald I; Schäfer R; Steinhauser E; Gradinger R
    Z Orthop Ihre Grenzgeb; 1999; 137(2):122-8. PubMed ID: 10408054
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Surface characterisation of shot peened implants with glas beads in total hip arthroplasty].
    Schuh A; Holzwarth U; Kachler W; Göske J; Zeiler G
    Zentralbl Chir; 2004 Jun; 129(3):225-9. PubMed ID: 15237332
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Technology of cementless hip endoprosthetics].
    Ungethüm M; Blömer W
    Orthopade; 1987 Jun; 16(3):170-84. PubMed ID: 3627790
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Silicate coating of cemented titanium-based shafts in hip prosthetics reduces high aseptic loosening].
    Marx R; Faramarzi R; Jungwirth F; Kleffner BV; Mumme T; Weber M; Wirtz DC
    Z Orthop Unfall; 2009; 147(2):175-82. PubMed ID: 19358071
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Cementless total hip arthroplasty--results of 8-year follow-up study].
    Wall A; Dragan S
    Wiad Lek; 2006; 59(5-6):336-40. PubMed ID: 17017478
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro.
    Kassi JP; Heller MO; Stoeckle U; Perka C; Duda GN
    J Biomech; 2005 May; 38(5):1143-54. PubMed ID: 15797595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Drive principles of a triaxial physiological hip joint simulator for wear testing of hip endoprostheses].
    Springstein D; Wendt Z; Boenick U
    Biomed Tech (Berl); 2003 Apr; 48(4):106-9. PubMed ID: 12749289
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Improved osseointegration of titanium implants of different surface characteristics by the use of bone morphogenetic protein (BMP-3): an animal study performed at the metaphyseal bone bed in dogs].
    Hartwig CH; Esenwein SA; Pfund A; Küsswetter Dagger W; Herr G
    Z Orthop Ihre Grenzgeb; 2003; 141(6):705-11. PubMed ID: 14679438
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Experiences with a hydroxyapatite-coated, macroporous surface hip endoprosthesis].
    Kinner B; Willmann G; Storz S; Kinner J
    Z Orthop Ihre Grenzgeb; 1999; 137(2):114-21. PubMed ID: 10408053
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The hollow prosthesis. Reflections on cementless hip endoprosthesis anchorage].
    Quack G; Rischke B; Bensmann G; Krahl H; Maronna U; Singewald M
    Z Orthop Ihre Grenzgeb; 1991; 129(5):453-9. PubMed ID: 1836702
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Stress analysis of an anatomically-adapted femur shaft prosthesis (Lubinus SPII)].
    Alter P; Lengsfeld M; Schmitt J
    Z Orthop Ihre Grenzgeb; 1999; 137(2):129-35. PubMed ID: 10408055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation].
    Prymka M; Vogiatzis M; Hassenpflug J
    Z Orthop Ihre Grenzgeb; 2004; 142(3):303-8. PubMed ID: 15250002
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Biomechanics of cement-free endoprostheses].
    Plitz W
    Z Orthop Ihre Grenzgeb; 1993; 131(6):483-7. PubMed ID: 8310734
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cementless implant fixation--toward improved reliability.
    Pilliar RM
    Orthop Clin North Am; 2005 Jan; 36(1):113-9. PubMed ID: 15542130
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Experiences, requirements and development of cement-free hip endoprostheses].
    Morscher E
    Orthopade; 1987 Jun; 16(3):185-96. PubMed ID: 3627791
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Further development of the graded-shaft fixation principle].
    Stock D; Barfuss M; Zailskas T
    Z Orthop Ihre Grenzgeb; 1993; 131(6):558-61. PubMed ID: 8310747
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cementless femoral design concerns. Rationale for extensive porous coating.
    Nourbash PS; Paprosky WG
    Clin Orthop Relat Res; 1998 Oct; (355):189-99. PubMed ID: 9917604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cementless total hip arthroplasty.
    Morscher EW
    Clin Orthop Relat Res; 1983 Dec; (181):76-91. PubMed ID: 6357588
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.