138 related articles for article (PubMed ID: 10413747)
1. Four-gated transcranial Doppler ultrasound in the detection of circulating microemboli.
Droste DW; Dittrich R; Hermes S; Kemény V; Schulte-Altedorneburg G; Hansberg T; Ringelstein EB
Eur J Ultrasound; 1999 May; 9(2):117-25. PubMed ID: 10413747
[TBL] [Abstract][Full Text] [Related]
2. Comparison of a 1-MHz and a 2-MHz probe for microembolus detection using transcranial Doppler ultrasound.
Droste DW; Lerner T; Dittrich R; Ritter M; Ringelstein EB
Neurol Res; 2005 Jul; 27(5):471-6. PubMed ID: 15978172
[TBL] [Abstract][Full Text] [Related]
3. Intracranial microembolic signals in 500 patients with potential cardiac or carotid embolic source and in normal controls.
Georgiadis D; Lindner A; Manz M; Sonntag M; Zunker P; Zerkowski HR; Borggrefe M
Stroke; 1997 Jun; 28(6):1203-7. PubMed ID: 9183352
[TBL] [Abstract][Full Text] [Related]
4. Automatic embolus detection by a neural network.
Kemény V; Droste DW; Hermes S; Nabavi DG; Schulte-Altedorneburg G; Siebler M; Ringelstein EB
Stroke; 1999 Apr; 30(4):807-10. PubMed ID: 10187883
[TBL] [Abstract][Full Text] [Related]
5. Automatic embolus detection compared with human experts. A Doppler ultrasound study.
Van Zuilen EV; Mess WH; Jansen C; Van der Tweel I; Van Gijn J; Ackerstaff GA
Stroke; 1996 Oct; 27(10):1840-3. PubMed ID: 8841342
[TBL] [Abstract][Full Text] [Related]
6. Automated intraoperative detection of Doppler microembolic signals using the bigate approach.
Georgiadis D; Wenzel A; Zerkowski HR; Zierz S; Lindner A
Stroke; 1998 Jan; 29(1):137-9. PubMed ID: 9445342
[TBL] [Abstract][Full Text] [Related]
7. Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler.
Brucher R; Russell D
Stroke; 2002 Aug; 33(8):1969-74. PubMed ID: 12154247
[TBL] [Abstract][Full Text] [Related]
8. Feasibility and reliability of on-line automated microemboli detection after carotid endarterectomy. A transcranial Doppler study.
Munts AG; Mess WH; Bruggemans EF; Walda L; Ackerstaff RG
Eur J Vasc Endovasc Surg; 2003 Mar; 25(3):262-6. PubMed ID: 12623339
[TBL] [Abstract][Full Text] [Related]
9. Identification of Doppler microembolic signals with a bigate probe in patients with prosthetic heart valves.
Lindner A; Georgiadis D; Fischer G; Zerkowski HR; Zierz S
Eur J Med Res; 1997 Jul; 2(7):299-301. PubMed ID: 9233904
[TBL] [Abstract][Full Text] [Related]
10. Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves.
Droste DW; Hagedorn G; Nötzold A; Siemens HJ; Sievers HH; Kaps M
Stroke; 1997 Mar; 28(3):588-92. PubMed ID: 9056616
[TBL] [Abstract][Full Text] [Related]
11. A new algorithm for off-line automated emboli detection based on the pseudo-wigner power distribution and the dual gate TCD technique.
Mess WH; Titulaer BM; Ackerstaff RG
Ultrasound Med Biol; 2000 Mar; 26(3):413-8. PubMed ID: 10773371
[TBL] [Abstract][Full Text] [Related]
12. Variability of Doppler microembolic signal counts in patients with prosthetic cardiac valves.
Georgiadis D; Kaps M; Siebler M; Hill M; König M; Berg J; Kahl M; Zunker P; Diehl B; Ringelstein EB
Stroke; 1995 Mar; 26(3):439-43. PubMed ID: 7886722
[TBL] [Abstract][Full Text] [Related]
13. Detection of high intensity transient signals (HITS): how and why?
Droste DW; Ringelstein EB
Eur J Ultrasound; 1998 Feb; 7(1):23-9. PubMed ID: 9614287
[TBL] [Abstract][Full Text] [Related]
14. Prevalence and time course of microembolic signals in patients with acute stroke. A prospective study.
Sliwka U; Lingnau A; Stohlmann WD; Schmidt P; Mull M; Diehl RR; Noth J
Stroke; 1997 Feb; 28(2):358-63. PubMed ID: 9040690
[TBL] [Abstract][Full Text] [Related]
15. A combined power m-mode and single gate transcranial doppler ultrasound microemboli signal criteria for improving emboli detection and reliability.
Choi Y; Saqqur M; Asil T; Jin A; Stewart E; Stephenson C; Ibrahim M; Roy J; Boulanger JM; Coutts S; Khan F; Demchuk AM
J Neuroimaging; 2010 Oct; 20(4):359-67. PubMed ID: 19912481
[TBL] [Abstract][Full Text] [Related]
16. Doppler microembolic signals in children with prosthetic cardiac valves.
Georgiadis D; Preiss M; Lindner A; Gybels Y; Zierz S; Zerkowski HR
Stroke; 1997 Jul; 28(7):1328-9. PubMed ID: 9227678
[TBL] [Abstract][Full Text] [Related]
17. Transcranial Doppler detection of microemboli in prosthetic heart valve patients: dependency upon valve type.
Georgiadis D; Kaps M; Berg J; Mackay TG; Dapper F; Faichney A; Wheatley DJ; Lees KR
Eur J Cardiothorac Surg; 1996; 10(4):253-7; discussion 257-8. PubMed ID: 8740061
[TBL] [Abstract][Full Text] [Related]
18. Detection of microemboli by transcranial Doppler ultrasound.
Grosset DG; Georgiadis D; Kelman AW; Cowburn P; Stirling S; Lees KR; Faichney A; Mallinson A; Quin R; Bone I; Pettigrew L; Brodie E; MacKay T; Wheatley DJ
Tex Heart Inst J; 1996; 23(4):289-92. PubMed ID: 8969029
[TBL] [Abstract][Full Text] [Related]
19. Differentiation between emboli and artefacts using dual-gated transcranial Doppler ultrasound.
Smith JL; Evans DH; Fan L; Bell PR; Naylor AR
Ultrasound Med Biol; 1996; 22(8):1031-6. PubMed ID: 9004426
[TBL] [Abstract][Full Text] [Related]
20. Transcranial Doppler-detected microemboli in patients with acute stroke.
Tong DC; Albers GW
Stroke; 1995 Sep; 26(9):1588-92. PubMed ID: 7660403
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]