These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 10414897)

  • 1. Effect of catheter placement on 3-D velocity profiles in curved tubes resembling the human coronary system.
    Krams R; Wentzel JJ; Cespedes I; Vinke R; Carlier S; van der Steen AF; Lancee CT; Slager CJ
    Ultrasound Med Biol; 1999 Jun; 25(5):803-10. PubMed ID: 10414897
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The impact of scaled boundary conditions on wall shear stress computations in atherosclerotic human coronary bifurcations.
    Schrauwen JT; Schwarz JC; Wentzel JJ; van der Steen AF; Siebes M; Gijsen FJ
    Am J Physiol Heart Circ Physiol; 2016 May; 310(10):H1304-12. PubMed ID: 26945083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of vessel curvature on Doppler derived velocity profiles and fluid flow.
    Krams R; Bambi G; Guidi F; Helderman F; van der Steen AF; Tortoli P
    Ultrasound Med Biol; 2005 May; 31(5):663-71. PubMed ID: 15866416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Relation between plaque type, plaque thickness, blood shear stress, and plaque stress in coronary arteries assessed by X-ray angiography and intravascular ultrasound.
    Balocco S; Gatta C; Alberti M; Carrillo X; Rigla J; Radeva P
    Med Phys; 2012 Dec; 39(12):7430-45. PubMed ID: 23231293
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Forward-viewing estimation of 3D blood flow velocity fields by intravascular ultrasound: Influence of the catheter on velocity estimation in stenoses.
    Kim S; Jing B; Lindsey BD
    Ultrasonics; 2021 Dec; 117():106558. PubMed ID: 34461527
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of model boundary conditions on blood flow patterns in a patient specific stenotic right coronary artery.
    Liu B; Zheng J; Bach R; Tang D
    Biomed Eng Online; 2015; 14 Suppl 1(Suppl 1):S6. PubMed ID: 25602370
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The influence of curvature wall on the blood flow in stenosed artery: A computational study.
    Ahamad NA; Kamangar S; Badruddin IA
    Biomed Mater Eng; 2018; 29(3):319-332. PubMed ID: 29578467
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A numerical calculation of flow in a curved tube model of the left main coronary artery.
    Perktold K; Nerem RM; Peter RO
    J Biomech; 1991; 24(3-4):175-89. PubMed ID: 2055907
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation.
    van Liebergen RA; Piek JJ; Koch KT; Peters RJ; de Winter RJ; Schotborgh CE; Lie KI
    J Am Coll Cardiol; 1999 Dec; 34(7):1899-906. PubMed ID: 10588201
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow.
    Madhavan S; Kemmerling EMC
    Biomed Eng Online; 2018 May; 17(1):66. PubMed ID: 29843730
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of curvature and stenosis-like narrowing on wall shear stress in a coronary artery model with phasic flow.
    Nosovitsky VA; Ilegbusi OJ; Jiang J; Stone PH; Feldman CL
    Comput Biomed Res; 1997 Feb; 30(1):61-82. PubMed ID: 9134307
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A computational study on the influence of catheter-delivered intravascular probes on blood flow in a coronary artery model.
    Torii R; Wood NB; Hughes AD; Thom SA; Aguado-Sierra J; Davies JE; Francis DP; Parker KH; Xu XY
    J Biomech; 2007; 40(11):2501-9. PubMed ID: 17258750
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flow in a catheterized curved artery with stenosis.
    Dash RK; Jayaraman G; Mehta KN
    J Biomech; 1999 Jan; 32(1):49-61. PubMed ID: 10050951
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A numerical study of flow in curved tubes simulating coronary arteries.
    Chang LJ; Tarbell JM
    J Biomech; 1988; 21(11):927-37. PubMed ID: 3253279
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Plaque rupture: plaque stress, shear stress, and pressure drop.
    Li ZY; Gillard JH
    J Am Coll Cardiol; 2008 Aug; 52(6):499-500; author reply 500. PubMed ID: 18672176
    [No Abstract]   [Full Text] [Related]  

  • 17. Influence of stenosis on hemodynamic parameters in the realistic left coronary artery under hyperemic conditions.
    Kamangar S; Badruddin IA; Badarudin A; Nik-Ghazali N; Govindaraju K; Salman Ahmed NJ; Yunus Khan TM
    Comput Methods Biomech Biomed Engin; 2017 Mar; 20(4):365-372. PubMed ID: 27612619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational model of blood flow in the aorto-coronary bypass graft.
    Sankaranarayanan M; Chua LP; Ghista DN; Tan YS
    Biomed Eng Online; 2005 Mar; 4():14. PubMed ID: 15745458
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of angiographic and IVUS derived coronary geometric reconstructions for evaluation of the association of hemodynamics with coronary artery disease progression.
    Timmins LH; Suo J; Eshtehardi P; Molony DS; McDaniel MC; Oshinski JN; Giddens DP; Samady H
    Int J Cardiovasc Imaging; 2016 Sep; 32(9):1327-1336. PubMed ID: 27229349
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does the inflow velocity profile influence physiologically relevant flow patterns in computational hemodynamic models of left anterior descending coronary artery?
    Lodi Rizzini M; Gallo D; De Nisco G; D'Ascenzo F; Chiastra C; Bocchino PP; Piroli F; De Ferrari GM; Morbiducci U
    Med Eng Phys; 2020 Aug; 82():58-69. PubMed ID: 32709266
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.