These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 10416415)
1. The osseous response to corundum blasted implant surfaces in a canine hip model. Hacking SA; Bobyn JD; Tanzer M; Krygier JJ Clin Orthop Relat Res; 1999 Jul; (364):240-53. PubMed ID: 10416415 [TBL] [Abstract][Full Text] [Related]
2. The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model. Feighan JE; Goldberg VM; Davy D; Parr JA; Stevenson S J Bone Joint Surg Am; 1995 Sep; 77(9):1380-95. PubMed ID: 7673290 [TBL] [Abstract][Full Text] [Related]
3. Effects of calcium ion implantation on osseointegration of surface-blasted titanium alloy femoral implants in a canine total hip arthroplasty model. Jinno T; Kirk SK; Morita S; Goldberg VM J Arthroplasty; 2004 Jan; 19(1):102-9. PubMed ID: 14716657 [TBL] [Abstract][Full Text] [Related]
4. Biological fixation of hydroxyapatite-coated versus grit-blasted titanium hip stems: a canine study. Eckardt A; Aberman HM; Cantwell HD; Heine J Arch Orthop Trauma Surg; 2003 Feb; 123(1):28-35. PubMed ID: 12582793 [TBL] [Abstract][Full Text] [Related]
5. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than fifty years old. Sporer SM; Callaghan JJ; Olejniczak JP; Goetz DD; Johnston RC J Bone Joint Surg Am; 1999 Apr; 81(4):481-92. PubMed ID: 10225793 [TBL] [Abstract][Full Text] [Related]
6. Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings. Hacking SA; Tanzer M; Harvey EJ; Krygier JJ; Bobyn JD Clin Orthop Relat Res; 2002 Dec; (405):24-38. PubMed ID: 12461353 [TBL] [Abstract][Full Text] [Related]
7. The removal of Al2O3 particles from grit-blasted titanium implant surfaces: effects on biocompatibility, osseointegration and interface strength in vivo. Rüger M; Gensior TJ; Herren C; von Walter M; Ocklenburg C; Marx R; Erli HJ Acta Biomater; 2010 Jul; 6(7):2852-61. PubMed ID: 20080212 [TBL] [Abstract][Full Text] [Related]
8. Comparative surface examinations on corund blasted titanium implants and explants in total hip arthroplasty. Schuh A; Uter W; Kachler W; Göske J; Zeiler G; Lill C Arch Orthop Trauma Surg; 2005 Dec; 125(10):676-82. PubMed ID: 16189687 [TBL] [Abstract][Full Text] [Related]
9. Strontium in the bone-implant interface. Vestermark MT Dan Med Bull; 2011 May; 58(5):B4286. PubMed ID: 21535993 [TBL] [Abstract][Full Text] [Related]
10. Effect of hydroxyapatite coating on the radio-clinical results of a grit-blasted titanium alloy femoral taper. A case-control study of 198 cementless primary total hip arthroplasty with the Alloclassic™ system. Delaunay C Orthop Traumatol Surg Res; 2014 Nov; 100(7):739-44. PubMed ID: 25261173 [TBL] [Abstract][Full Text] [Related]
11. Influence of implant surface topography on bone-regenerative potential and mechanical retention in the human maxilla and mandible. Wei N; Bin S; Jing Z; Wei S; Yingqiong Z Am J Dent; 2014 Jun; 27(3):171-6. PubMed ID: 25208367 [TBL] [Abstract][Full Text] [Related]
12. Contamination of surfaces for osseointegration of cementless total hip implants by small aluminium oxide particles: analysis of established implants by use of a new technique. Kolb A; Reinisch G; Sabeti-Aschraf M; Grübl A; Windhager R J Orthop Sci; 2013 Mar; 18(2):245-9. PubMed ID: 23203846 [TBL] [Abstract][Full Text] [Related]
13. Characterization of five different implant surfaces and their effect on osseointegration: a study in dogs. Coelho PG; Bonfante EA; Pessoa RS; Marin C; Granato R; Giro G; Witek L; Suzuki M J Periodontol; 2011 May; 82(5):742-50. PubMed ID: 21054223 [TBL] [Abstract][Full Text] [Related]
14. Histomorphometric analysis of the osseointegration of four different implant surfaces in the femoral epiphyses of rabbits. Le Guehennec L; Goyenvalle E; Lopez-Heredia MA; Weiss P; Amouriq Y; Layrolle P Clin Oral Implants Res; 2008 Nov; 19(11):1103-10. PubMed ID: 18983312 [TBL] [Abstract][Full Text] [Related]
15. Effects of NSAIDs and hydroxyapatite coating on osseointegration. Salduz A; Dikici F; Kılıçoğlu ÖI; Balcı HI; Akgul T; Kürkçü M; Kurtoğlu C; Tözün R J Orthop Surg (Hong Kong); 2017 Jan; 25(1):2309499016684410. PubMed ID: 28139193 [TBL] [Abstract][Full Text] [Related]
16. [Surface characterization of Al2O3-blasted titanium implants in total hip arthroplasty]. Schuh A; Holzwarth U; Kachler W; Göske J; Zeiler G Orthopade; 2004 Aug; 33(8):905-10. PubMed ID: 15150684 [TBL] [Abstract][Full Text] [Related]
17. Characterization, quantification, and isolation of aluminum oxide particles on grit blasted titanium aluminum alloy hip implants. Grübl A; Kolb A; Reinisch G; Fafilek G; Skrbensky G; Kotz R J Biomed Mater Res B Appl Biomater; 2007 Oct; 83(1):127-31. PubMed ID: 17330891 [TBL] [Abstract][Full Text] [Related]
18. Implant-delivered Alendronate Causes a Dose-dependent Response on Net Bone Formation Around Porous Titanium Implants in Canines. Pura JA; Bobyn JD; Tanzer M Clin Orthop Relat Res; 2016 May; 474(5):1224-33. PubMed ID: 26831478 [TBL] [Abstract][Full Text] [Related]