BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 10421551)

  • 1. Planning target volumes for radiotherapy: how much margin is needed?
    Antolak JA; Rosen II
    Int J Radiat Oncol Biol Phys; 1999 Jul; 44(5):1165-70. PubMed ID: 10421551
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy.
    Killoran JH; Kooy HM; Gladstone DJ; Welte FJ; Beard CJ
    Int J Radiat Oncol Biol Phys; 1997 Jan; 37(1):213-21. PubMed ID: 9054898
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.
    Stroom JC; de Boer HC; Huizenga H; Visser AG
    Int J Radiat Oncol Biol Phys; 1999 Mar; 43(4):905-19. PubMed ID: 10098447
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of dosimetric margins in prostate IMRT treatment plans.
    Gordon JJ; Siebers JV
    Med Phys; 2008 Feb; 35(2):569-75. PubMed ID: 18383678
    [TBL] [Abstract][Full Text] [Related]  

  • 5. PTV margin determination in conformal SRT of intracranial lesions.
    Parker BC; Shiu AS; Maor MH; Lang FF; Liu HH; White RA; Antolak JA
    J Appl Clin Med Phys; 2002; 3(3):176-89. PubMed ID: 12132939
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer.
    Yan D; Lockman D; Brabbins D; Tyburski L; Martinez A
    Int J Radiat Oncol Biol Phys; 2000 Aug; 48(1):289-302. PubMed ID: 10925000
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.
    van Herk M; Remeijer P; Rasch C; Lebesque JV
    Int J Radiat Oncol Biol Phys; 2000 Jul; 47(4):1121-35. PubMed ID: 10863086
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Isotoxic dose escalation in the treatment of lung cancer by means of heterogeneous dose distributions in the presence of respiratory motion.
    Baker M; Nielsen M; Hansen O; Jahn JW; Korreman S; Brink C
    Int J Radiat Oncol Biol Phys; 2011 Nov; 81(3):849-55. PubMed ID: 21570211
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Adequate margins for random setup uncertainties in head-and-neck IMRT.
    Astreinidou E; Bel A; Raaijmakers CP; Terhaard CH; Lagendijk JJ
    Int J Radiat Oncol Biol Phys; 2005 Mar; 61(3):938-44. PubMed ID: 15708278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Beyond the margin recipe: the probability of correct target dosage and tumor control in the presence of a dose limiting structure.
    Witte MG; Sonke JJ; Siebers J; Deasy JO; van Herk M
    Phys Med Biol; 2017 Sep; 62(19):7874-7888. PubMed ID: 28832334
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Variable planning margin approach to account for locoregional variations in setup uncertainties.
    Yang J; Garden AS; Zhang Y; Zhang L; Dong L
    Med Phys; 2012 Aug; 39(8):5136-44. PubMed ID: 22894439
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Loss of local control due to tumor displacement as a function of margin size, dose-response slope, and number of fractions.
    Selvaraj J; Uzan J; Baker C; Nahum A
    Med Phys; 2013 Apr; 40(4):041715. PubMed ID: 23556885
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The impact of microscopic disease on the tumor control probability in non-small-cell lung cancer.
    Siedschlag C; Boersma L; van Loon J; Rossi M; van Baardwijk A; Gilhuijs K; Stroom J
    Radiother Oncol; 2011 Sep; 100(3):344-50. PubMed ID: 21955665
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors.
    Gordon JJ; Siebers JV
    Phys Med Biol; 2007 Apr; 52(7):1967-90. PubMed ID: 17374922
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiotherapy margin design with particular consideration of high curvature CTVs.
    Herschtal A; Kron T; Fox C
    Med Phys; 2009 Mar; 36(3):684-97. PubMed ID: 19378729
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inclusion of geometric uncertainties in treatment plan evaluation.
    van Herk M; Remeijer P; Lebesque JV
    Int J Radiat Oncol Biol Phys; 2002 Apr; 52(5):1407-22. PubMed ID: 11955756
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A study of nonuniform CTV to PTV margin expansion incorporating both rotational and translational uncertainties.
    Miao J; Xu Y; Tian Y; Liu Z; Dai J
    J Appl Clin Med Phys; 2019 Dec; 20(12):78-86. PubMed ID: 31793203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intensity-modulated radiotherapy for soft tissue sarcoma of the thigh.
    Hong L; Alektiar KM; Hunt M; Venkatraman E; Leibel SA
    Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):752-9. PubMed ID: 15183478
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Margins for translational and rotational uncertainties: a probability-based approach.
    Remeijer P; Rasch C; Lebesque JV; van Herk M
    Int J Radiat Oncol Biol Phys; 2002 Jun; 53(2):464-74. PubMed ID: 12023151
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.
    Ricotti R; Seregni M; Ciardo D; Vigorito S; Rondi E; Piperno G; Ferrari A; Zerella MA; Arculeo S; Francia CM; Sibio D; Cattani F; De Marinis F; Spaggiari L; Orecchia R; Riboldi M; Baroni G; Jereczek-Fossa BA
    Med Phys; 2018 Apr; 45(4):1360-1368. PubMed ID: 29431863
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.