These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 10424706)

  • 21. Biomechanical evaluation of a crimp clamp system for loop fixation of monofilament nylon leader material used for stabilization of the canine stifle joint.
    Anderson CC; Tomlinson JL; Daly WR; Carson WL; Payne JT; Wagner-Mann CC
    Vet Surg; 1998; 27(6):533-9. PubMed ID: 9845216
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Mechanical comparison of materials used for extra-capsular stabilisation of the stifle joint in dogs.
    Lewis DD; Milthorpe BK; Bellenger CR
    Aust Vet J; 1997 Dec; 75(12):890-6. PubMed ID: 9469225
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Mechanical performance of square knots and sliding knots in surgery: comparative study.
    van Rijssel EJ; Trimbos JB; Booster MH
    Am J Obstet Gynecol; 1990 Jan; 162(1):93-7. PubMed ID: 2154104
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of tensile and knot security properties of surgical sutures.
    Kim JC; Lee YK; Lim BS; Rhee SH; Yang HC
    J Mater Sci Mater Med; 2007 Dec; 18(12):2363-9. PubMed ID: 17569012
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Mechanical behaviour of three types of surgical knots using 4/0 monofilament].
    Gil Santos L; Más-Estellés J; Salmerón Sánchez M; Barrios C
    Cir Esp; 2012; 90(6):388-93. PubMed ID: 22494710
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study.
    Meyer DC; Bachmann E; Lädermann A; Lajtai G; Jentzsch T
    Orthop Traumatol Surg Res; 2018 Dec; 104(8):1277-1282. PubMed ID: 30327262
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Knotting abilities of a new absorbable monofilament suture: poliglecaprone 25 (Monocryl).
    Trimbos JB; Niggebrugge A; Trimbos R; Van Rijssel EJ
    Eur J Surg; 1995 May; 161(5):319-22. PubMed ID: 7662774
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Influence of surgeon's tying technique on knot security.
    Batra EK; Franz DA; Towler MA; Rodeheaver GT; Thacker JG; Zimmer CA; Edlich RF
    J Appl Biomater; 1993; 4(3):241-7. PubMed ID: 10146307
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Mechanical knot performance of a new generation polydioxanon suture (PDS-2).
    Trimbos JB; Booster M; Peters AA
    Acta Obstet Gynecol Scand; 1991; 70(2):157-9. PubMed ID: 1909081
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Arthroscopic suture material and knot type: an updated biomechanical analysis.
    Swan KG; Baldini T; McCarty EC
    Am J Sports Med; 2009 Aug; 37(8):1578-85. PubMed ID: 19470946
    [TBL] [Abstract][Full Text] [Related]  

  • 31. How reliable is intracorporeal laparoscopic knot tying?
    Lopez PJ; Veness J; Wojcik A; Curry J
    J Laparoendosc Adv Surg Tech A; 2006 Aug; 16(4):428-32. PubMed ID: 16968200
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Some biomechanical considerations of polytetrafluoroethylene sutures.
    Dang MC; Thacker JG; Hwang JC; Rodeheaver GT; Melton SM; Edlich RF
    Arch Surg; 1990 May; 125(5):647-50. PubMed ID: 2331223
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Knotting technique and suture materials.
    Brown RP
    Br J Surg; 1992 May; 79(5):399-400. PubMed ID: 1596717
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Initial loop and knot security of arthroscopic knots using high-strength sutures.
    Shah MR; Strauss EJ; Kaplan K; Jazrawi L; Rosen J
    Arthroscopy; 2007 Aug; 23(8):884-8. PubMed ID: 17681211
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Knot Security of 5 Metric (USP 2) Sutures: Influence of Knotting Technique, Suture Material, and Incubation Time for 14 and 28 Days in Phosphate Buffered Saline and Inflamed Equine Peritoneal Fluid.
    Sanders RE; Kearney CM; Buckley CT; Jenner F; Brama PA
    Vet Surg; 2015 Aug; 44(6):723-30. PubMed ID: 25998193
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Tying a loop-to-strand suture: is it safe?
    Hurt J; Unger JB; Ivy JJ; Mukherjee D; Pizzaro A
    Am J Obstet Gynecol; 2005 Apr; 192(4):1094-7. PubMed ID: 15846186
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of using a surgical clamp to hold tension while tying knots with commonly used orthopedic sutures.
    Bisson LJ; Sobel AD; Godfrey D
    Knee Surg Sports Traumatol Arthrosc; 2012 Sep; 20(9):1673-80. PubMed ID: 21922319
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Shortcuts in arthroscopic knot tying: do they affect knot and loop security?
    Riboh JC; Heckman DS; Glisson RR; Moorman CT
    Am J Sports Med; 2012 Jul; 40(7):1572-7. PubMed ID: 22582226
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of ultrasonic suture welding and traditional knot tying.
    Richmond JC
    Am J Sports Med; 2001; 29(3):297-9. PubMed ID: 11394598
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Knot properties of alternating sliding knots with different patterns in comparison to alternating and simple sliding knots.
    Babetty Z; Sümer A; Altintaş S
    J Am Coll Surg; 1998 Apr; 186(4):485-9. PubMed ID: 9544964
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.