These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Heterozygote and mutation detection by direct automated fluorescent DNA sequencing using a mutant Taq DNA polymerase. Chadwick RB; Conrad MP; McGinnis MD; Johnston-Dow L; Spurgeon SL; Kronick MN Biotechniques; 1996 Apr; 20(4):676-83. PubMed ID: 8800689 [TBL] [Abstract][Full Text] [Related]
23. Automated cycle sequencing with Taquenase: protocols for internal labeling, dye primer and "doublex" simultaneous sequencing. Voss H; Nentwich U; Duthie S; Wiemann S; Benes V; Zimmermann J; Ansorge W Biotechniques; 1997 Aug; 23(2):312-8. PubMed ID: 9266089 [TBL] [Abstract][Full Text] [Related]
24. Sequence length and error analysis of Sequenase and automated Taq cycle sequencing methods. Koop BF; Rowan L; Chen WQ; Deshpande P; Lee H; Hood L Biotechniques; 1993 Mar; 14(3):442-7. PubMed ID: 8457352 [TBL] [Abstract][Full Text] [Related]
25. Truncated fragments in polymerase chain reaction-based DNA sequencing. Westberg J; Holmberg A; Uhlén M; Pettersson B Electrophoresis; 1999 Mar; 20(3):502-10. PubMed ID: 10217163 [TBL] [Abstract][Full Text] [Related]
26. Screening for point mutations by semi-automated DNA sequencing using sequenase and magnetic beads. Leren TP; Rødningen OK; Røsby O; Solberg K; Berg K Biotechniques; 1993 Apr; 14(4):618-23. PubMed ID: 8476605 [TBL] [Abstract][Full Text] [Related]
27. External-loop free energy affects dye-labeled terminators premature terminations in DNA cycle-sequencing reactions. Wen L Mol Biotechnol; 2002 Nov; 22(3):243-52. PubMed ID: 12448879 [TBL] [Abstract][Full Text] [Related]
29. Peak height variations in automated sequencing of PCR products using Taq dye-terminator chemistry. Parker LT; Deng Q; Zakeri H; Carlson C; Nickerson DA; Kwok PY Biotechniques; 1995 Jul; 19(1):116-21. PubMed ID: 7669285 [TBL] [Abstract][Full Text] [Related]
30. Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments. Xu Y; Vaidya B; Patel AB; Ford SM; McCarley RL; Soper SA Anal Chem; 2003 Jul; 75(13):2975-84. PubMed ID: 12964741 [TBL] [Abstract][Full Text] [Related]
31. DNA sequencing with a hexamer string primer and dye-labeled terminators. Hou W; Smith LM Anal Biochem; 1994 Aug; 221(1):136-41. PubMed ID: 7985784 [TBL] [Abstract][Full Text] [Related]
32. Fluorescence-based sequencing of double-stranded DNA by hexamer string priming. Johnson AF; Lodhi MA; McCombie WR Anal Biochem; 1996 Oct; 241(2):228-37. PubMed ID: 8921192 [TBL] [Abstract][Full Text] [Related]
33. High performance DNA sequencing, and the detection of mutations and polymorphisms, on the Clipper sequencer. Yager TD; Baron L; Batra R; Bouevitch A; Chan D; Chan K; Darasch S; Gilchrist R; Izmailov A; Lacroix JM; Marchelleta K; Renfrew J; Renfrew J; Rushlow D; Steinbach E; Ton C; Waterhouse P; Zaleski H; Dunn JM; Stevens J Electrophoresis; 1999 Jun; 20(6):1280-300. PubMed ID: 10380769 [TBL] [Abstract][Full Text] [Related]
34. DNA sequencing with dye-labeled terminators and T7 DNA polymerase: effect of dyes and dNTPs on incorporation of dye-terminators and probability analysis of termination fragments. Lee LG; Connell CR; Woo SL; Cheng RD; McArdle BF; Fuller CW; Halloran ND; Wilson RK Nucleic Acids Res; 1992 May; 20(10):2471-83. PubMed ID: 1598205 [TBL] [Abstract][Full Text] [Related]
35. Elimination of band compression in sequencing gels by the use of N4-methyl-2'-deoxycytidine 5'-triphosphate. Li S; Haces A; Stupar L; Gebeyehu G; Pless RC Nucleic Acids Res; 1993 Jun; 21(11):2709-14. PubMed ID: 8332468 [TBL] [Abstract][Full Text] [Related]
36. [The Effect of the Chromophore Charge on the Efficiency of Incorporation of Fluorescently-labeled Nucleotides in Matrix Synthesis by Taq DNA Polymerase]. Shershov VE; Kuznetsova VE; Lysov YP; Guseinov TO; Barsky VE; Spitsyn MA; Zasedateleva OA; Vasiliskov VA; Surzhikov SA; Zasedatelev AS; Chudinov AV Biofizika; 2015; 60(6):1216-8. PubMed ID: 26841520 [TBL] [Abstract][Full Text] [Related]
37. Automated fluorescent dye-terminator sequencing of G+C-rich tracts with the aid of dimethyl sulfoxide. Scheidl TM; Miura Y; Yee HA; Tamaoki T Biotechniques; 1995 Nov; 19(5):691-4. PubMed ID: 8588896 [No Abstract] [Full Text] [Related]
38. Identification of the DNA bases of a DNase I footprint by the use of dye primer sequencing on an automated capillary DNA analysis instrument. Zianni M; Tessanne K; Merighi M; Laguna R; Tabita FR J Biomol Tech; 2006 Apr; 17(2):103-13. PubMed ID: 16741237 [TBL] [Abstract][Full Text] [Related]
39. Rapid cycle sequencing in an air thermal cycler. Swerdlow H; Dew-Jager K; Gesteland RF Biotechniques; 1993 Sep; 15(3):512-9. PubMed ID: 8217167 [TBL] [Abstract][Full Text] [Related]
40. DMSO resolves certain compressions and signal dropouts in fluorescent dye labeled primer-based DNA sequencing reactions. Seto D; Seto J; Deshpande P; Hood L DNA Seq; 1995; 5(3):131-40. PubMed ID: 7612923 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]