These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 10434359)

  • 41. Assessment of amputee socket-stump-residual bone kinematics during strenuous activities using Dynamic Roentgen Stereogrammetric Analysis.
    Papaioannou G; Mitrogiannis C; Nianios G; Fiedler G
    J Biomech; 2010 Mar; 43(5):871-8. PubMed ID: 20047746
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Gait rehabilitation for a patient with an osseointegrated prosthesis following transfemoral amputation.
    Leijendekkers RA; van Hinte G; Nijhuis-van der Sanden MW; Staal JB
    Physiother Theory Pract; 2017 Feb; 33(2):147-161. PubMed ID: 28045571
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The TC double socket above-knee prosthesis.
    Koike K; Ishikura Y; Kakurai S; Imamura T
    Prosthet Orthot Int; 1981 Dec; 5(3):129-34. PubMed ID: 7329773
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Dynamic alignment using external socket reaction moments in trans-tibial amputees.
    Jonkergouw N; Prins MR; van der Wurff P; Gijsbers J; Houdijk H; Buis AWP
    Gait Posture; 2019 Feb; 68():122-129. PubMed ID: 30472524
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges.
    Paterno L; Ibrahimi M; Gruppioni E; Menciassi A; Ricotti L
    IEEE Trans Biomed Eng; 2018 Sep; 65(9):1996-2010. PubMed ID: 29993506
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait.
    Convery P; Murray KD
    Prosthet Orthot Int; 2000 Dec; 24(3):226-32. PubMed ID: 11195358
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A comparative study of conventional and energy-storing prosthetic feet in high-functioning transfemoral amputees.
    Graham LE; Datta D; Heller B; Howitt J; Pros D
    Arch Phys Med Rehabil; 2007 Jun; 88(6):801-6. PubMed ID: 17532907
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Patient satisfaction following lower-limb amputation: the role of gait deviation.
    Kark L; Simmons A
    Prosthet Orthot Int; 2011 Jun; 35(2):225-33. PubMed ID: 21558305
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Roentgenological study of certain stump-socket relationships in above-knee amputees with special regard to tissue proportions, socket fit and attachment stability.
    Erikson U; James U
    Ups J Med Sci; 1973 Jul; 78(3):203-14. PubMed ID: 4766848
    [No Abstract]   [Full Text] [Related]  

  • 50. The comparison of transfemoral amputees using mechanical and microprocessor- controlled prosthetic knee under different walking speeds: A randomized cross-over trial.
    Cao W; Yu H; Zhao W; Meng Q; Chen W
    Technol Health Care; 2018; 26(4):581-592. PubMed ID: 29710741
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Residual limb wounds or ulcers heal in transtibial amputees using an active suction socket system. A randomized controlled study.
    Traballesi M; Delussu AS; Fusco A; Iosa M; Averna T; Pellegrini R; Brunelli S
    Eur J Phys Rehabil Med; 2012 Dec; 48(4):613-23. PubMed ID: 22641248
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Sprint kinematics of athletes with lower-limb amputations.
    Buckley JG
    Arch Phys Med Rehabil; 1999 May; 80(5):501-8. PubMed ID: 10326911
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A comparison between the suction suspension system and the hypobaric Iceross Seal-InĀ® X5 in transtibial amputees.
    Brunelli S; Delussu AS; Paradisi F; Pellegrini R; Traballesi M
    Prosthet Orthot Int; 2013 Dec; 37(6):436-44. PubMed ID: 23436696
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Relaxed versus activated stump muscles during casting for trans-tibial prostheses.
    Lilja M; Johansson S; Oberg T
    Prosthet Orthot Int; 1999 Apr; 23(1):13-20. PubMed ID: 10355639
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Modeling and simulation of muscle forces of trans-tibial amputee to study effect of prosthetic alignment.
    Fang L; Jia X; Wang R
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1125-31. PubMed ID: 17942203
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A Swedish knee-cage for stabilizing short below-knee stumps.
    Isakov E; Mizrahi J; Susak Z; Onna I
    Prosthet Orthot Int; 1992 Aug; 16(2):114-7. PubMed ID: 1408669
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Transfemoral prosthesis suspension systems: a systematic review of the literature.
    Gholizadeh H; Abu Osman NA; Eshraghi A; Ali S
    Am J Phys Med Rehabil; 2014 Sep; 93(9):809-23. PubMed ID: 24743451
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Piezoelectric bimorphs' characteristics as in-socket sensors for transfemoral amputees.
    El-Sayed AM; Hamzaid NA; Abu Osman NA
    Sensors (Basel); 2014 Dec; 14(12):23724-41. PubMed ID: 25513823
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Total surface bearing below-knee prosthesis: advantages, disadvantages, and clinical implications.
    Hachisuka K; Dozono K; Ogata H; Ohmine S; Shitama H; Shinkoda K
    Arch Phys Med Rehabil; 1998 Jul; 79(7):783-9. PubMed ID: 9685091
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies.
    Buis AW; Convery P
    Prosthet Orthot Int; 1997 Dec; 21(3):179-82. PubMed ID: 9453089
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.