These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 10435536)

  • 1. Measurement of thickness and density of thin structures by computed tomography: a simulation study.
    Dougherty G; Newman D
    Med Phys; 1999 Jul; 26(7):1341-8. PubMed ID: 10435536
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of CT-based thickness measurement of thin structures: modeling of limited spatial resolution in all three dimensions.
    Prevrhal S; Fox JC; Shepherd JA; Genant HK
    Med Phys; 2003 Jan; 30(1):1-8. PubMed ID: 12557971
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters.
    Prevrhal S; Engelke K; Kalender WA
    Phys Med Biol; 1999 Mar; 44(3):751-64. PubMed ID: 10211808
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Model-based PSF and MTF estimation and validation from skeletal clinical CT images.
    Pakdel A; Mainprize JG; Robert N; Fialkov J; Whyne CM
    Med Phys; 2014 Jan; 41(1):011906. PubMed ID: 24387514
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An effective method to verify line and point spread functions measured in computed tomography.
    Ohkubo M; Wada S; Matsumoto T; Nishizawa K
    Med Phys; 2006 Aug; 33(8):2757-64. PubMed ID: 16964851
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method to determine cortical bone thickness in CT images using a hybrid approach of parametric profile representation and local adaptive thresholds: Accuracy results.
    Museyko O; Gerner B; Engelke K
    PLoS One; 2017; 12(11):e0187097. PubMed ID: 29107950
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A method for determining the modulation transfer function from thick microwire profiles measured with x-ray microcomputed tomography.
    Nakaya Y; Kawata Y; Niki N; Umetatni K; Ohmatsu H; Moriyama N
    Med Phys; 2012 Jul; 39(7):4347-64. PubMed ID: 22830768
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.
    Humbert L; Hazrati Marangalou J; Del Río Barquero LM; van Lenthe GH; van Rietbergen B
    Med Phys; 2016 Apr; 43(4):1945. PubMed ID: 27036590
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Independent measurement of femoral cortical thickness and cortical bone density using clinical CT.
    Treece GM; Gee AH
    Med Image Anal; 2015 Feb; 20(1):249-64. PubMed ID: 25541355
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Limitations of clinical CT in assessing cortical thickness and density.
    Newman DL; Dougherty G; al Obaid A; al Hajrasy H
    Phys Med Biol; 1998 Mar; 43(3):619-26. PubMed ID: 9533140
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Imaging of small high-density structures in CT A phantom study.
    Rollano-Hijarrubia E; Stokking R; van der Meer F; Niessen WJ
    Acad Radiol; 2006 Jul; 13(7):893-908. PubMed ID: 16777564
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Generalized method for computation of true thickness and x-ray intensity information in highly blurred sub-millimeter bone features in clinical CT images.
    Pakdel A; Robert N; Fialkov J; Maloul A; Whyne C
    Phys Med Biol; 2012 Dec; 57(23):8099-116. PubMed ID: 23159920
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Model-based cartilage thickness measurement in the submillimeter range.
    Streekstra GJ; Strackee SD; Maas M; ter Wee R; Venema HW
    Med Phys; 2007 Sep; 34(9):3562-70. PubMed ID: 17926959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transconvolution and the virtual positron emission tomograph--a new method for cross calibration in quantitative PET∕CT imaging.
    Prenosil GA; Weitzel T; Hentschel M; Klaeser B; Krause T
    Med Phys; 2013 Jun; 40(6):062503. PubMed ID: 23718608
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Recommendations for thresholds for cortical bone geometry and density measurement by peripheral quantitative computed tomography.
    Ward KA; Adams JE; Hangartner TN
    Calcif Tissue Int; 2005 Nov; 77(5):275-80. PubMed ID: 16307388
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of point spread function in computed tomography accompanied with verification.
    Ohkubo M; Wada S; Ida S; Kunii M; Kayugawa A; Matsumoto T; Nishizawa K; Murao K
    Med Phys; 2009 Jun; 36(6):2089-97. PubMed ID: 19610298
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accurate quantification of width and density of bone structures by computed tomography.
    Hangartner TN; Short DF
    Med Phys; 2007 Oct; 34(10):3777-84. PubMed ID: 17985623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of finite spatial resolution on the measurement of cardiac phantom wall thickness in single photon emission computerized tomographic imaging.
    Ballani N; Dougherty G
    Med Princ Pract; 2004; 13(6):316-24. PubMed ID: 15467306
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Presampling, algorithm factors, and noise: considerations for CT in particular and for medical imaging in general.
    Kachelriess M; Kalender WA
    Med Phys; 2005 May; 32(5):1321-34. PubMed ID: 15984684
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spiral CT image deblurring for cochlear implantation.
    Wang G; Vannier MW; Skinner MW; Cavalcanti MG; Harding GW
    IEEE Trans Med Imaging; 1998 Apr; 17(2):251-62. PubMed ID: 9688157
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.