BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 10436903)

  • 1. TLD dose measurement: a simplified accurate technique for the dose range from 0.5 cGy to 1000 cGy.
    Yu C; Luxton G
    Med Phys; 1999 Jun; 26(6):1010-6. PubMed ID: 10436903
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Instrumentation and dosimeter-size artifacts in quantitative thermoluminescence dosimetry of low-dose fields.
    Meigooni AS; Mishra V; Panth H; Williamson J
    Med Phys; 1995 May; 22(5):555-61. PubMed ID: 7643791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reproducibility study of TLD-100 micro-cubes at radiotherapy dose level.
    da Rosa LA; Regulla DF; Fill UA
    Appl Radiat Isot; 1999 Mar; 50(3):573-7. PubMed ID: 10070716
    [TBL] [Abstract][Full Text] [Related]  

  • 4. TLD measurements of the relative output factors for the Leksell Gamma Knife.
    Yu C; Luxton G; Apuzzo ML; Petrovich Z
    Stereotact Funct Neurosurg; 1999; 72 Suppl 1():150-8. PubMed ID: 10681703
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response of TLD-100 in mixed fields of photons and electrons.
    Lawless MJ; Junell S; Hammer C; DeWerd LA
    Med Phys; 2013 Jan; 40(1):012103. PubMed ID: 23298105
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermoluminescent dosimetry of the SourceTech Medical model STM1251 125I seed.
    Chiu-Tsao ST; Duckworth TL; Hsiung CY; Li Z; Williamson J; Patel NS; Harrison LB
    Med Phys; 2003 Jul; 30(7):1732-5. PubMed ID: 12906190
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments.
    Mobit PN; Mayles P; Nahum AE
    Phys Med Biol; 1996 Mar; 41(3):387-98. PubMed ID: 8778821
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of effectiveness of thermoluminescent crystals LiF:Mg,Ti, and LiF:Mg,Cu,P for clinical dosimetry.
    Harris CK; Elson HR; Lamba MA; Foster AE
    Med Phys; 1997 Sep; 24(9):1527-9. PubMed ID: 9304583
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SU-E-T-92: on the Use of High-Sensitivity Thermoluminescent Dosimeters (TLDs) for Dosimetric Characterization of Low-Energy Brachytherapy Sources.
    Chen Z; Bongiorni P; Donahue W; Hearn R; Rodgers J; Nath R
    Med Phys; 2012 Jun; 39(6Part11):3723. PubMed ID: 28517162
    [TBL] [Abstract][Full Text] [Related]  

  • 10. UV-induced second readout of LiF thermoluminescent dosimeters in the therapeutic dose range.
    Zwicker RD; Wu A; Sternick ES
    Med Phys; 1983; 10(4):472-4. PubMed ID: 6888361
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry.
    Yoshizumi TT; Goodman PC; Frush DP; Nguyen G; Toncheva G; Sarder M; Barnes L
    AJR Am J Roentgenol; 2007 May; 188(5):1332-6. PubMed ID: 17449779
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thermoluminescent dosimetry of the selectseed 125I interstitial brachytherapy seed.
    Anagnostopoulos G; Baltas D; Karaiskos P; Sandilos P; Papagiannis P; Sakelliou L
    Med Phys; 2002 May; 29(5):709-16. PubMed ID: 12033566
    [TBL] [Abstract][Full Text] [Related]  

  • 13. LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co.
    Nunn AA; Davis SD; Micka JA; DeWerd LA
    Med Phys; 2008 May; 35(5):1859-69. PubMed ID: 18561661
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.
    Geise RA; Schueler BA; Lien W; Jones SC
    Med Phys; 1997 Oct; 24(10):1643-6. PubMed ID: 9350720
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical use of carbon-loaded thermoluminescent dosimeters for skin dose determination.
    Ostwald PM; Kron T; Hamilton CS; Denham JW
    Int J Radiat Oncol Biol Phys; 1995 Nov; 33(4):943-50. PubMed ID: 7591907
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.
    Low DA; Dempsey JF; Venkatesan R; Mutic S; Markman J; Mark Haacke E; Purdy JA
    Med Phys; 1999 Aug; 26(8):1542-51. PubMed ID: 10501054
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An in-house developed resettable MOSFET dosimeter for radiotherapy.
    Verellen D; Van Vaerenbergh S; Tournel K; Heuninckx K; Joris L; Duchateau M; Linthout N; Gevaert T; Reynders T; Van de Vondel I; Coppens L; Depuydt T; De Ridder M; Storme G
    Phys Med Biol; 2010 Feb; 55(4):N97-109. PubMed ID: 20090184
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The variability of clinical thermoluminescent dosimetry systems: a multi-institutional study.
    Amols HI; Weinhous MS; Reinstein LE
    Med Phys; 1987; 14(2):291-5. PubMed ID: 3587157
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.