  • 21. Growing cava vein anastomosis: comparison of cross-clamping and suture times using VCS metallic clips, interrupted nonabsorbable, or continuous absorbable suturing techniques.
    Calles-Vázquez MC; Abellán Rubio E; Ayala VC; Usón Gargallo J; Sánchez Margallo FM
    Ann Vasc Surg; 2013 Oct; 27(7):947-53. PubMed ID: 23993110
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A new probe for the anastomosis of small vessels.
    Sano T; Yasutsune T; Ooishi Y; Tokunaga S; Yasui H
    Ann Thorac Cardiovasc Surg; 2003 Apr; 9(2):142-5. PubMed ID: 12732095
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of the Unilink microvascular anastomotic device in the dog.
    Falconer DP; Lewis TW; Lamprecht EG; Mendenhall HV
    J Reconstr Microsurg; 1990 Jul; 6(3):215-22. PubMed ID: 2292782
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Non-suture end-to-end anastomoses between polytetrafluoroethylene graft and vessels for blood access.
    Sumimoto K; Tanaka I; Fukuda Y; Haruta N; Dohi K; Ito H; Tsuchiya T; Ikada Y
    Panminerva Med; 1999 Mar; 41(1):72-7. PubMed ID: 10230263
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Microvascular anastomoses performed in rats using a microsurgical telemanipulator.
    Li RA; Jensen J; Bowersox JC
    Comput Aided Surg; 2000; 5(5):326-32. PubMed ID: 11169878
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Challenging Alexis Carrel: a study in alternate microvascular techniques.
    Aviles AJ; Theodorou S; Sekosen M; Schraufnagel D; Ramasastry S
    Neurol Res; 2004 Dec; 26(8):809-15. PubMed ID: 15727264
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evolution of staples and clips for vascular anastomoses.
    Zeebregts CJ; Kirsch WM; van den Dungen JJ; van Schilfgaarde R; Zhu YH
    Int Surg; 2004; 89(3):152-60. PubMed ID: 15521252
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Laser-assisted end-to-end vascular anastomosis of elastin heterograft to carotid artery with an albumin stent in vivo.
    Xie H; Bendre SC; Gregory KW; Furnary AP
    Photomed Laser Surg; 2004 Aug; 22(4):298-302. PubMed ID: 15345171
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Factors determining late patency of aortobifemoral bypass graft].
    Davidović LB; Lotina SI; Kostić DM; Cinara II; Cvetković SD; Stojanov PL; Velimirović DB; Marković MM; Pejkić SA; Vukotić AM
    Srp Arh Celok Lek; 1997; 125(1-2):24-35. PubMed ID: 17974352
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A proof-of-principle study on animals for a new method of anastomosing vessels using intraluminal stents.
    Prabhu IS; Homer-Vanniasinkam S
    J Craniomaxillofac Surg; 2013 Jun; 41(4):327-30. PubMed ID: 23218979
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ballooning method using a dull-tipped needle for patency maintenance during venous anastomosis.
    Yoshimatsu H; Yamamoto T; Narushima M; Iida T; Koshima I
    Microsurgery; 2014 Feb; 34(2):167-8. PubMed ID: 23946185
    [No Abstract]   [Full Text] [Related]  

  • 32. Effect of torsion on microarterial anastomosis patency.
    Topalan M; Bilgin SS; Ip WY; Chow SP
    Microsurgery; 2003; 23(1):56-9. PubMed ID: 12616520
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Vessel anastomosis using a venous cuff and two sutures: an experimental study in rat femoral and epigastric vessels.
    Nakayama Y; Soeda S; Kiyosawa T
    J Reconstr Microsurg; 1988 Jul; 4(4):335-9. PubMed ID: 3050066
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Vascular anastomosis in femoral artery of a dog using an approximator double clamp].
    González Alvarez P; Hernández-Siverio N; Friend H; Gómez Culebras MA; Pérez Palma J; González Hermoso F
    Rev Quir Esp; 1988; 15(3):144-7. PubMed ID: 3153382
    [No Abstract]   [Full Text] [Related]  

  • 35. An absorbable anastomotic device for microvascular surgery: experimental studies.
    Daniel RK; Olding M
    Plast Reconstr Surg; 1984 Sep; 74(3):329-36. PubMed ID: 6473553
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Vascular microanastomosis in rat femoral arteries: experimental study comparing non-absorbable and absorbable sutures.
    Claude O; Grégory T; Montemagno S; Bruneval P; Masmejean EH
    J Reconstr Microsurg; 2007 Feb; 23(2):87-91. PubMed ID: 17330204
    [TBL] [Abstract][Full Text] [Related]  

  • 37. End-to-side-anastomosis in the dog using the 3M precise microvascular anastomotic system: a comparative study.
    Li YN; Wood MB
    J Reconstr Microsurg; 1991 Oct; 7(4):345-50; discussion 351-2. PubMed ID: 1753377
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Use of a micropunch for arteriotomy in end-to-side anastomosis.
    Hallock GG; Rice DC
    J Reconstr Microsurg; 1996 Jan; 12(1):59-62; discussion 62-3. PubMed ID: 8618229
    [TBL] [Abstract][Full Text] [Related]  

  • 39. End-to-side and end-to-end vascular anastomoses with a carbon dioxide laser.
    Nakata S; Campbell CD; Pick R; Replogle RL
    J Thorac Cardiovasc Surg; 1989 Jul; 98(1):57-62. PubMed ID: 2739426
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Polydioxanone absorbable sutures in vascular anastomoses: experimental and preliminary clinical studies.
    Wang ZG; Pu LQ; Li GD; Du W; Symes JF
    Cardiovasc Surg; 1994 Aug; 2(4):508-13. PubMed ID: 7953459
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]