BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 10454112)

  • 21. The accuracy and precision of DXA for assessing body composition in team sport athletes.
    Bilsborough JC; Greenway K; Opar D; Livingstone S; Cordy J; Coutts AJ
    J Sports Sci; 2014; 32(19):1821-8. PubMed ID: 24914773
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Body composition analysis by dual energy X-ray absorptiometry in female diabetics differ between manufacturers.
    Kistorp CN; Svendsen OL
    Eur J Clin Nutr; 1997 Jul; 51(7):449-54. PubMed ID: 9234027
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Dual energy X-ray absorptiometry: inter-machine variability.
    Tataranni PA; Pettitt DJ; Ravussin E
    Int J Obes Relat Metab Disord; 1996 Nov; 20(11):1048-50. PubMed ID: 8923164
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments.
    Tothill P; Laskey MA; Orphanidou CI; van Wijk M
    Br J Radiol; 1999 Jul; 72(859):661-9. PubMed ID: 10624323
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dual energy x-ray laser measurement of calcaneal bone mineral density.
    Hakulinen MA; Saarakkala S; Töyräs J; Kröger H; Jurvelin JS
    Phys Med Biol; 2003 Jun; 48(12):1741-52. PubMed ID: 12870580
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of the Lunar Prodigy and iDXA Dual-Energy X-ray Absorptiometers for Assessing Total and Regional Body Composition.
    Morrison SA; Petri RM; Hunter HL; Raju D; Gower B
    J Clin Densitom; 2016; 19(3):290-7. PubMed ID: 26209017
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparison of phantoms for cross-calibration of lumbar spine DXA.
    Pearson D; Cawte SA; Green DJ
    Osteoporos Int; 2002 Dec; 13(12):948-54. PubMed ID: 12459937
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of a new body composition phantom for quality control and cross-calibration of DXA devices.
    Diessel E; Fuerst T; Njeh CF; Tylavsky F; Cauley J; Dockrell M; Genant HK
    J Appl Physiol (1985); 2000 Aug; 89(2):599-605. PubMed ID: 10926643
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dual-energy X-ray absorptiometry and body composition.
    Laskey MA
    Nutrition; 1996 Jan; 12(1):45-51. PubMed ID: 8838836
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a phantom for morphometric X-ray absorptiometry.
    Rea JA; Blake GM; Fogelman I
    Br J Radiol; 2001 Apr; 74(880):341-50. PubMed ID: 11387153
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Fan beam dual energy X-ray absorptiometry body composition measurements in piglets.
    Chauhan S; Koo WW; Hammami M; Hockman EM
    J Am Coll Nutr; 2003 Oct; 22(5):408-14. PubMed ID: 14559933
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Impact of bone mineral estimates on percent fat estimates from a four-component model.
    Modlesky CM; Evans EM; Millard-Stafford ML; Collins MA; Lewis RD; Cureton KJ
    Med Sci Sports Exerc; 1999 Dec; 31(12):1861-8. PubMed ID: 10613441
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dual X-ray absorptiometry: cross-calibration of a new fan-beam system.
    Blake GM; Harrison EJ; Adams JE
    Calcif Tissue Int; 2004 Jul; 75(1):7-14. PubMed ID: 15037973
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Validation of a dual energy X-ray absorptiometer: measurement of bone mass and soft tissue composition.
    Madsen OR; Jensen JE; Sørensen OH
    Eur J Appl Physiol Occup Physiol; 1997; 75(6):554-8. PubMed ID: 9202954
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparisons between Hologic QDR 1000W, QDR 4500A, and Lunar Expert dual-energy X-ray absorptiometry scanners used for measuring total body bone and soft tissue.
    Tothill P; Hannan WJ
    Ann N Y Acad Sci; 2000 May; 904():63-71. PubMed ID: 10865711
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measurement precision of body composition variables using the lunar DPX-L densitometer.
    Kiebzak GM; Leamy LJ; Pierson LM; Nord RH; Zhang ZY
    J Clin Densitom; 2000; 3(1):35-41. PubMed ID: 10745300
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of the European Spine Phantom in a multi-centre clinical trial.
    Lees B; Garland SW; Walton C; Stevenson JC
    Osteoporos Int; 1997; 7(6):570-4. PubMed ID: 9604054
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Quantitative Comparison of 2 Dual-Energy X-ray Absorptiometry Systems in Assessing Body Composition and Bone Mineral Measurements.
    Xu W; Chafi H; Guo B; Heymsfield SB; Murray KB; Zheng J; Jia G
    J Clin Densitom; 2016; 19(3):298-304. PubMed ID: 26206525
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Body composition analysis of small pigs by dual-energy x-ray absorptiometry.
    Mitchell AD; Scholz AM; Conway JM
    J Anim Sci; 1998 Sep; 76(9):2392-8. PubMed ID: 9781495
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Patient-specific DXA bone mineral density inaccuracies: quantitative effects of nonuniform extraosseous fat distributions.
    Bolotin HH; Sievänen H; Grashuis JL
    J Bone Miner Res; 2003 Jun; 18(6):1020-7. PubMed ID: 12817754
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.