These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 10456634)
21. The chronotropic response of the sinus node to exercise: a new method of analysis and a study of pacemaker patients. Crook B; Nijhof P; van der Kemp P; Jennison C Eur Heart J; 1995 Jul; 16(7):993-8. PubMed ID: 7498217 [TBL] [Abstract][Full Text] [Related]
22. [Chronic frequency-adaptive pacemaker therapy in patients with heart failure]. Haltern G; Kempa L; Ochs JG; Hanrath P; Sigmund M Z Kardiol; 1995 Oct; 84(10):834-43. PubMed ID: 7502571 [TBL] [Abstract][Full Text] [Related]
23. A prospective multicenter study demonstrating clinical benefit with a new accelerometer-based DDDR pacemaker. Dromos Dr Investigators Group. Lazarus A; Mitchell K Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1694-7. PubMed ID: 8945026 [TBL] [Abstract][Full Text] [Related]
24. Apparent extension of the atrioventricular interval due to sensor-based algorithm against supraventricular tachyarrhythmias. Leung SK; Lau CP; Leung WH; Tai YT; Chung F; Chow YH Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):321-30. PubMed ID: 7513857 [TBL] [Abstract][Full Text] [Related]
25. AAI pacing mode: when is it indicated and how should it be achieved? Katritsis D; Camm AJ Clin Cardiol; 1993 Apr; 16(4):339-43. PubMed ID: 8458114 [TBL] [Abstract][Full Text] [Related]
26. The effect of maximum heart rate on oxygen kinetics and exercise performance at low and high workloads. Carmouche DG; Bubien RS; Kay GN Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):679-86. PubMed ID: 9584297 [TBL] [Abstract][Full Text] [Related]
27. Reliability of a new algorithm for automatic mode switching from DDDR to DDIR pacing mode in sinus node disease patients with chronotropic incompetence and recurrent paroxysmal atrial fibrillation. Ricci R; Puglisi A; Azzolini P; Spampinato A; Pignalberi C; Bellocci F; Adinolfi E; Dini P; Cavaglià S; De Seta F Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1719-23. PubMed ID: 8945030 [TBL] [Abstract][Full Text] [Related]
28. Stability of AV conduction in sick sinus node syndrome patients with implanted atrial pacemakers. Hayes DL; Furman S Am Heart J; 1984 Apr; 107(4):644-7. PubMed ID: 6702557 [TBL] [Abstract][Full Text] [Related]
29. Doppler echocardiographic assessment of the hemodynamic benefits of rate adaptive AV delay during exercise in paced patients with complete heart block. Sheppard RC; Ren JF; Ross J; McAllister M; Chandrasekaran K; Kutalek SP Pacing Clin Electrophysiol; 1993 Nov; 16(11):2157-67. PubMed ID: 7505929 [TBL] [Abstract][Full Text] [Related]
30. Effective Management of Atrioventricular Interval for Paroxysmal Atrial Fibrillation That Developed After DDDR Pacemaker Implantation in a Sick Sinus Syndrome Patient. Tasaki H; Ashizawa N; Nagao S; Fukushima K; Furukawa R; Fukae S; Maemura K Int Heart J; 2015; 56(5):558-63. PubMed ID: 26370366 [TBL] [Abstract][Full Text] [Related]
31. Comparison of effects of propranolol versus pindolol on sinus rate and pacing frequency in sick sinus syndrome. Strickberger SA; Fish RD; Lamas GA; Cantillon C; Bhatia S; McGowan N; Antman EM; Friedman PL Am J Cardiol; 1993 Jan; 71(1):53-6. PubMed ID: 8420236 [TBL] [Abstract][Full Text] [Related]
35. Long-term haemodynamic and antiarrhythmic benefits of DDIR versus DDI pacing mode in sick sinus syndrome and chronotropic incompetence. Santini M; Ricci R; Puglisi A; Mangiameli S; Proclemer A; Menozzi C; De Fabrizio G; Leoni G; Lisi F; De Seta F G Ital Cardiol; 1997 Sep; 27(9):892-900. PubMed ID: 9378194 [TBL] [Abstract][Full Text] [Related]
36. Clinical evaluation of peak endocardial acceleration as a sensor for rate responsive pacing. Greco EM; Ferrario M; Romano S Pacing Clin Electrophysiol; 2003 Apr; 26(4 Pt 1):812-8. PubMed ID: 12715840 [TBL] [Abstract][Full Text] [Related]