154 related articles for article (PubMed ID: 10457486)
1. Determination of niobium(V) and tantalum(V) as 4-(2-pyridylazo)resorcinol-citrate ternary complexes in geological materials by ion-interaction reversed-phase high-performance liquid chromatography.
Vachirapatama N; Macka M; Paull B; Münker C; Haddad PR
J Chromatogr A; 1999 Jul; 850(1-2):257-68. PubMed ID: 10457486
[TBL] [Abstract][Full Text] [Related]
2. On-line preconcentration of niobium(V) and tantalum(V) as 4-(2-pyridylazo) resorcinol-citrate ternary complexes in geological samples by ion interaction high-performance liquid chromatography.
Vachirapatama N; Doble P; Haddad PR
J Chromatogr A; 2000 Jul; 885(1-2):369-75. PubMed ID: 10941684
[TBL] [Abstract][Full Text] [Related]
3. Determination of vanadium as 4-(2-pyridylazo)resorcinol-hydrogen peroxide ternary complexes by ion-interaction reversed-phase liquid chromatography.
Vachirapatama N; Dicinoski GW; Townsend AT; Haddad PR
J Chromatogr A; 2002 May; 956(1-2):221-7. PubMed ID: 12108654
[TBL] [Abstract][Full Text] [Related]
4. Separation and simultaneous determination of niobium and tantalum in steel by reversed-phase high-performance liquid chromatography using 2-(2-pyridylazo)-5-diethylamino phenol as a pre-column derivatizing reagent.
Dongling L; Xiaoyan H; Haizhou W
Talanta; 2004 May; 63(2):233-7. PubMed ID: 18969422
[TBL] [Abstract][Full Text] [Related]
5. Development of a capillary electrophoresis method for the analysis in alkaline media as polyoxoanions of two strategic metals: Niobium and tantalum.
Deblonde GJ; Chagnes A; Cote G; Vial J; Rivals I; Delaunay N
J Chromatogr A; 2016 Mar; 1437():210-218. PubMed ID: 26868447
[TBL] [Abstract][Full Text] [Related]
6. [Determination of trace niobium and tantalum in rock sample by atomic emission spectrometry].
Li HZ; Zhou CL; Luo CN
Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Oct; 22(5):843-4. PubMed ID: 12938446
[TBL] [Abstract][Full Text] [Related]
7. Fast simultaneous determination of niobium and tantalum by Kalman Filter analysis with flow injection chemiluminescence method.
Wang H; Li J; Chen Z; Liu M; Wang H
Anal Sci; 2005 Sep; 21(9):1051-5. PubMed ID: 16363472
[TBL] [Abstract][Full Text] [Related]
8. Determination of V(V), Nb(V) and Ta(V) as their 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol chelates by reversed-phase HPLC.
Wang H; Miao YX; Zhang HS; Cheng JK
Talanta; 1994 May; 41(5):685-9. PubMed ID: 18965983
[TBL] [Abstract][Full Text] [Related]
9. Quantitative analysis of manganese, chromium and molybdenum by ion-pair reversed-phase high-performance liquid chromatography with pre-column derivatization and UV-visible detection.
Sun HL; Liu HM; Tsai SJ
J Chromatogr A; 1999 Oct; 857(1-2):351-7. PubMed ID: 10536856
[TBL] [Abstract][Full Text] [Related]
10. [On-line determination of niobium and tantalum in soil and geochemical exploration samples by inductively coupled plasma atomic emission spectrometry with solvent extraction flow injection].
Ai J; Tang ZY
Guang Pu Xue Yu Guang Pu Fen Xi; 2001 Oct; 21(5):658-60. PubMed ID: 12945323
[TBL] [Abstract][Full Text] [Related]
11. Separation of vanadium, niobium and tantalum as ternary mixed-ligand complexes by capillary electrophoresis using chelation with 4-(2-pyridylazo)resorcinol and tartaric acid.
Liu BF; Liu LB; Chen H; Cheng JK
Fresenius J Anal Chem; 2001 Jan; 369(2):195-7. PubMed ID: 11225366
[TBL] [Abstract][Full Text] [Related]
12. Determination of cobalt, nickel and iron at trace level in natural water samples by in-column chelation-reversed phase high-performance liquid chromatography.
Hol A; Divrikli U; Elci L
Environ Monit Assess; 2012 Jun; 184(6):3469-79. PubMed ID: 21701886
[TBL] [Abstract][Full Text] [Related]
13. Reversed-phase high performance liquid chromatography-spectrophotometry of several platinum group metal complexes with 4-(5-Nitro-2-pyridylazo)resorcinol.
Zhang HS; Mou WY; Cheng JK
Talanta; 1994 Sep; 41(9):1459-63. PubMed ID: 18966089
[TBL] [Abstract][Full Text] [Related]
14. Matrix isolation infrared spectroscopic and theoretical studies on the reactions of niobium and tantalum mono- and dioxides with methane.
Wang G; Lai S; Chen M; Zhou M
J Phys Chem A; 2005 Oct; 109(42):9514-20. PubMed ID: 16866402
[TBL] [Abstract][Full Text] [Related]
15. Solvent-Impregnated Sorbents for Tantalum from Niobium Separation Using a Fixed-Bed Column.
Turkowska M; Karoń K; Milewski A; Jakóbik-Kolon A
Materials (Basel); 2022 Feb; 15(4):. PubMed ID: 35208050
[TBL] [Abstract][Full Text] [Related]
16. Niobium- and tantalum-based ethylene polymerisation catalysts bearing methylene- or dimethyleneoxa-bridged calixarene ligands.
Redshaw C; Rowan M; Homden DM; Elsegood MR; Yamato T; Pérez-Casas C
Chemistry; 2007; 13(36):10129-39. PubMed ID: 17918176
[TBL] [Abstract][Full Text] [Related]
17. Dynamically modified C
Thirumalai M; Kumar SN; Prabhakaran D; Sivaraman N; Maheswari MA
J Chromatogr A; 2018 Sep; 1569():62-69. PubMed ID: 30025611
[TBL] [Abstract][Full Text] [Related]
18. Determination of quercetin in human plasma using reversed-phase high-performance liquid chromatography.
Liu B; Anderson D; Ferry DR; Seymour LW; de Takats PG; Kerr DJ
J Chromatogr B Biomed Appl; 1995 Apr; 666(1):149-55. PubMed ID: 7655613
[TBL] [Abstract][Full Text] [Related]
19. Simultaneous determination of zirconium and hafnium as ternary complexes with 5-Br-PADAP and fluoride using solid-phase extraction and reversed-phase liquid chromatography.
Oszwałdowski S; Jakubowska J
Talanta; 2003 Jul; 60(4):643-52. PubMed ID: 18969088
[TBL] [Abstract][Full Text] [Related]
20. Determination of dye precursors in hair coloring products by liquid chromatography with electrochemical detection.
Narita M; Murakami K; Kauffmann JM
Anal Chim Acta; 2007 Apr; 588(2):316-20. PubMed ID: 17386826
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]